This article presents the study of the structural performance of a set of timbrel vaults belonging to the so-called Administration Pavilion of the Hospital de Sant Pau, a large-scale hospital complex located in Barcelona. The article includes three parts. First, the Administration pavilion of Hospital de Sant Pau is described by putting the emphasis on the geometry of the masonry vaults and the combined utilization of steel and masonry structural members. Second, laboratory and in-situ experiments are discussed. Finally, the behavior observed during the dynamic-identification and the static-loading tests is simulated by means of FEM analysis. The FEM models prepared to analyse the vaults take explicitly into account the direct effect of secondary masonry structural elements, such as the upper slab and the extrados stiffening diaphragms. The comparison indicates that the consideration of these structural elements is essential for an adequate FEM simulation of both the dynamic and the static behavior of the timbrel vaults.
1 November 2020 in Construction and Building Materials
Brick masonry is a very widely used building method. A specific example of use of this masonry is the thin-tile vault. This is characterised by the format of several layers joined together with mortar and in which the position of the bricks means that they bear the load on edges. The main objective of this study is an assessment, based on experimental results, of clay brick masonry behavior when the load is applied parallel to the face of the bricks instead of perpendicular thereto. This study compares the stress-strain behavior, failure modes, compressive strength, and Young’s modulus of this type of masonry with data obtained from scientific literature.
In this study, experimental analysis on the compressive strength of multi-leaf thin-tile masonry is presented. A compressive strength test was carried out on thin-tile, mortar and 48 specimens with two- and three-leaf thin-tile masonry. The results obtained were compared with literature on brick masonry loaded parallel to a bed joint. Based on the results of this study, the failure mode presented the first crack in the vertical interface; this crack grew until the leaf was detached. From this point until collapse, lateral buckling of the leaves was generally observed. Therefore, the detachment compressive strength value was considered relevant. Up to this point, both masonries exhibit similar stress–strain behavior. The experimental values of the detachment compressive strength were compared with the values calculated from the equation generally used in the literature to evaluate the compressive strength of brick masonry. From the results obtained, the following conclusion can be drawn: This equation is only suitable for tree-leaf thin-tile masonry but with more relevant influence on the compressive strength of the mortar. This study concluded that only three-leaf specimens behave similarly to brick masonry loaded parallel to a bed joint. Finally, whether the failure mode was due to shear or tensile stresses in the vertical thin-tile-mortar interface cannot be identified.