Per Goltermann

Dr. Per Goltermann


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2012 in Construction and Building Materials
Verified
Journal Article
Closed access
JSJacob Wittrup Schmidt
Jacob Wittrup Schmidt
ABAnders Bennitz
Anders Bennitz
BTBjörn Täljsten
Björn Täljsten
PGPer Goltermann
Per Goltermann
HPHenning Pedersen
Henning Pedersen

7 July 2021 in Infrastructures
Verified
Journal Article
Open access
PDF file
CCChristian Overgaard Christensen
Christian Overgaard Christensen
JSJacob Wittrup Schmidt
Jacob Wittrup Schmidt
PHPhilip Skov Halding
Philip Skov Halding
MKMedha Kapoor
Medha Kapoor
PGPer Goltermann
Per Goltermann
In proof-loading of concrete slab bridges, advanced monitoring methods are required for identification of stop criteria. In this study, Two-Dimensional Digital Image Correlation (2D DIC) is investigated as one of the governing measurement methods for crack detection and evaluation. The investigations are deemed to provide valuable information about DIC capabilities under different environmental conditions and to evaluate the capabilities in relation to stop criterion verifications. Three Overturned T-beam (OT) Reinforced Concrete (RC) slabs are used for the assessment. Of these, two are in situ strips (0.55 × 3.6 × 9.0 m) cut from a full-scale OT-slab bridge with a span of 9 m and one is a downscaled slab tested under laboratory conditions (0.37 × 1.7 × 8.4 m). The 2D DIC results includes full-field plots, investigation of the time of crack detection and monitoring of crack widths. Grey-level transformation was used for the in situ tests to ensure sufficient readability and results comparable to the laboratory test. Crack initiation for the laboratory test (with speckle pattern) and in situ tests (plain concrete surface) were detected at intervals of approximately 0.1 mm to 0.3 mm and 0.2 mm to 0.3 mm, respectively. Consequently, the paper evaluates a more qualitative approach to DIC test results, where crack indications and crack detection can be used as a stop criterion. It was furthermore identified that crack initiation was reached at high load levels, implying the importance of a target load.

1 June 2011 in Journal of Composites for Construction
Verified
Journal Article
Closed access
JSJacob Wittrup Schmidt
Jacob Wittrup Schmidt
SSScott T. Smith
Scott T. Smith
BTBjörn Täljsten
Björn Täljsten
ABAnders Bennitz
Anders Bennitz
PGPer Goltermann
Per Goltermann
HPHenning Pedersen
Henning Pedersen
The tensioning of carbon-fiber-reinforced polymer (CFRP) rods for prestressed concrete applications or posttensioning repair and strengthening has been met with mixed success. This is primarily because of limitations inherent in the use of traditional wedge anchors typically used for steel tendons. Recently, an integrated sleeve-wedge anchorage has been successfully developed specifically for CFRP rods. This paper presents a numerical simulation of the newly developed anchorage by using ABAQUS. The three-dimensional (3D) finite-element (FE) model, which considers material nonlinearity, uses hexagonal elements for the barrel, CFRP rod, and tetrahedral elements for the integrated sleeve wedge. The simulated barrel surface strains are shown to compare well with optically measured strains; however, the numerical results are shown to be sensitive to the mechanical properties of the anchorage and CFRP rod and especially the transverse elastic modulus of the CFRP rod. Finally, the simulated strain distributions ...

30 September 2016 in International Journal of Sustainable Development and Planning
Verified
Journal Article
Open access
PDF file
Lisbeth Mølgaard M. OttosenLisbeth Mølgaard M. Ottosen
Lisbeth Mølgaard M. Ottosen
EHEsben Østergaard Hansen
Esben Østergaard Hansen
PJPernille Erland Jensen
Pernille Erland Jensen
GKGunvor M. Kirkelund
Gunvor M. Kirkelund
PGPer Goltermann
Per Goltermann
Wood ash (WA) is the residue generated during incineration of wood and wood products. The WAs in focus of this work are from incineration of virgin...

8 March 2022 in Infrastructures
Verified
Journal Article
Open access
PDF file
CCChristian Overgaard Christensen
Christian Overgaard Christensen
FZFengqiao Zhang
Fengqiao Zhang
GGGabriela ZARATE GARNICA
Gabriela ZARATE GARNICA
Eva LantsoghtEva Lantsoght
Eva Lantsoght
PGPer Goltermann
Per Goltermann
JSJacob Wittrup Schmidt
Jacob Wittrup Schmidt
Advanced monitoring methods are required to identify stop criteria in proof-load tests. In this study, the combined methodology of two-dimensional digital image correlation and acoustic emission is investigated for its applicability for future implementation in field tests. The two monitoring systems are deemed to provide valuable insight with external measurements from digital image correlation and internal measurements from acoustic emission. Two overturned T-section reinforced concrete slabs (0.37 × 1.7 × 8.4 m) tested under laboratory conditions are used for the assessment. The first slab test served as a preliminary test to enable sensor placement and creation of a relevant loading protocol. The main scientific results lead to a proposal for a test procedure using the combined methodology based on results, observations, and experiences from an individual stop criteria assessment for the two methods. The results include full-field plots, an investigation of the time of crack detection and monitoring of crack widths with digital image correlation, and a qualitative assessment of activity vs. load followed by a quantitative evaluation of calm ratios using acoustic emission. The individual results show that both digital image correlation and acoustic emission can identify damage occurrence earlier than other secondary methods. At crack detection (415 kN), crack widths were measured at widths between 0.078 mm to 0.125 mm and can be monitored until reaching the stop criterion at 463 kN (Eurocode SLS threshold of wmax = 0.2 mm). The acoustic emission results were limited by the pre-defined loading protocol and thus, only indicated that damage occurred sometime between 300 kN and 500 kN (pre-defined load levels). Therefore, the proposal for test procedure involves a methodology, where the loading protocol may be updated during testing based on monitoring results and thus provide even more valuable data.

1 July 2012 in ACI Structural Journal
Verified
Journal Article
Closed access
PDF file
ABAnders Bennitz
Anders Bennitz
JSJacob Wittrup Schmidt
Jacob Wittrup Schmidt
Jonny NilimaaJonny Nilimaa
Jonny Nilimaa
BTBjorn Taljsten
Bjorn Taljsten
PGPer Goltermann
Per Goltermann
DRDorthe Lund Ravn
Dorthe Lund Ravn