In proof-loading of concrete slab bridges, advanced monitoring methods are required for identification of stop criteria. In this study, Two-Dimensional Digital Image Correlation (2D DIC) is investigated as one of the governing measurement methods for crack detection and evaluation. The investigations are deemed to provide valuable information about DIC capabilities under different environmental conditions and to evaluate the capabilities in relation to stop criterion verifications. Three Overturned T-beam (OT) Reinforced Concrete (RC) slabs are used for the assessment. Of these, two are in situ strips (0.55 × 3.6 × 9.0 m) cut from a full-scale OT-slab bridge with a span of 9 m and one is a downscaled slab tested under laboratory conditions (0.37 × 1.7 × 8.4 m). The 2D DIC results includes full-field plots, investigation of the time of crack detection and monitoring of crack widths. Grey-level transformation was used for the in situ tests to ensure sufficient readability and results comparable to the laboratory test. Crack initiation for the laboratory test (with speckle pattern) and in situ tests (plain concrete surface) were detected at intervals of approximately 0.1 mm to 0.3 mm and 0.2 mm to 0.3 mm, respectively. Consequently, the paper evaluates a more qualitative approach to DIC test results, where crack indications and crack detection can be used as a stop criterion. It was furthermore identified that crack initiation was reached at high load levels, implying the importance of a target load.
Advanced reliability assessment can be required when evaluating existing bridge structures through proof load testing. The target load of a proof load test typically requires input from resistance models; however, bridges with a low documentation level are often the most relevant for proof load testing, and resistance models thus involve significant uncertainties. This paper presents a different approach to proof loading and target proof load, in which the resistance model is not included in the determination of this load. Instead, the target proof load is determined based on load models coupled to the desired target failure probability, thus ensuring sufficient safety of the existing bridge. The method is in line with the proposal for a new Eurocode on assessment of existing structures and is deemed to be superior to existing approaches. An essential assumption of the method is that monitoring systems can identify stop criteria before irreversible damage occurs. The approach was applied in a case study, where an OT-slab bridge with a span of 6.5 m was proof-load-tested and reclassified for capacity upgrading of a road stretch in Denmark.
Advanced monitoring methods are required to identify stop criteria in proof-load tests. In this study, the combined methodology of two-dimensional digital image correlation and acoustic emission is investigated for its applicability for future implementation in field tests. The two monitoring systems are deemed to provide valuable insight with external measurements from digital image correlation and internal measurements from acoustic emission. Two overturned T-section reinforced concrete slabs (0.37 × 1.7 × 8.4 m) tested under laboratory conditions are used for the assessment. The first slab test served as a preliminary test to enable sensor placement and creation of a relevant loading protocol. The main scientific results lead to a proposal for a test procedure using the combined methodology based on results, observations, and experiences from an individual stop criteria assessment for the two methods. The results include full-field plots, an investigation of the time of crack detection and monitoring of crack widths with digital image correlation, and a qualitative assessment of activity vs. load followed by a quantitative evaluation of calm ratios using acoustic emission. The individual results show that both digital image correlation and acoustic emission can identify damage occurrence earlier than other secondary methods. At crack detection (415 kN), crack widths were measured at widths between 0.078 mm to 0.125 mm and can be monitored until reaching the stop criterion at 463 kN (Eurocode SLS threshold of wmax = 0.2 mm). The acoustic emission results were limited by the pre-defined loading protocol and thus, only indicated that damage occurred sometime between 300 kN and 500 kN (pre-defined load levels). Therefore, the proposal for test procedure involves a methodology, where the loading protocol may be updated during testing based on monitoring results and thus provide even more valuable data.
Significant strengthening of concrete structures can be obtained when using adhesively-bonded carbon fiber-reinforced polymer (CFRP) systems. Challenges related to such strengthening methods are; however, the brittle concrete delamination failure, reduced warning, and the consequent inefficient use of the CFRP. A novel ductile near-surface mounted reinforcement (NSMR) CFRP strengthening system with a high CFRP utilization is introduced in this paper. It is hypothesized that the tailored ductile enclosure wedge (EW) end anchors, in combination with low E-modulus and high elongation adhesive, can provide significant strengthening and ductility control. Five concrete T-beams were strengthened using the novel system with a CFRP rod activation stress of approximately 980 MPa. The beam responses were compared to identical epoxy-bonded NSMR strengthened and un-strengthened beams. The linear elastic response was identical to the epoxy-bonded NSMR strengthened beam. In addition, the average deflection and yielding regimes were improved by 220% and 300% (average values), respectively, with an ultimate capacity comparable to the epoxy-bonded NSMR strengthened beam. Reproducible and predictable strengthening effect seems obtainable, where a good correlation between the results and applied theory was reached. The brittle failure modes were prevented, where concrete compression failure and frontal overload anchor failure were experienced when failure was initiated.
Novel and complex structural solutions are often challenging to introduce in the building industry since they may provide unconventional and less verified behavior combined with several novel and unique failure modes. A desired safety level may be difficult to verify due to the lack of knowledge related to failure modes and their variation. This study introduces a method that may provide a first step toward addressing such challenges. Five laboratory tests were done on a novel ductile response-controlled anchor system used for prestressed CFRP NSMR strengthening. These results were used as a basis for further implementation in a pilot project where an in situ cast concrete bridge was strengthened with the developed system. A particular focus was dedicated to the capability of the designed system response to provide a consistent load/deformation curve, yielding threshold, and yielding regime. The novel system enabled response tailoring to the specific pilot project. Installation and prestressing procedure worked as desired, where losses in the fully prestressed system, after three weeks, were approximately 0.2 to 1.6 kN (0.2–1.3 mm). In situ proof loading of all strengthening systems (20 anchor systems) was done to eliminate any possible failure modes below the proof-loading level. It was performed with no signs of distress.