Qiangqiang Xie

Mr. Qiangqiang Xie

School of Mechanical Science and Engineering, Huazhong University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SXSiwei Xie
Siwei Xie
ZZZhiliang Zhu
Zhiliang Zhu
Xi ZhangXi Zhang
Xi Zhang
QXQiangqiang Xie
Qiangqiang Xie
HYHongsen Yu
Hongsen Yu
QPQiyu Peng
Qiyu Peng
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction (DOI) for positron emission tomography (PET) detectors. In the present study, the effects of the multi-ended readout design were investigated using the leading-edge discriminator (LED) triggers on the timing performance of time-of-flight (TOF) PET detectors. At the very first, the photon transmission model of the four detectors, namely, single-ended readout, dual-ended readout, side dual-ended readout, and triple-ended readout, was established in Tracepro. The optical simulation revealed that the light output of the multi-ended readout was higher. Meanwhile, the readout circuit could be triggered earlier. Especially, in the triple-ended readout, the light output at 0.5 ns was observed to be nearly twice that of the single-ended readout after the first scintillating photon was generated. Subsequently, a reference detector was applied to test the multi-ended readout detectors that were constructed from a 6 × 6 × 25 mm3 LYSO crystal. Each module is composed of a crystal coupled with multiple SiPMs. Accordingly, its timing performance was improved by approximately 10% after the compensation of fourth-order polynomial fitting. Finally, the compensated full-width-at-half-maximum (FWHM) coincidence timing resolutions (CTR) of the dual-ended readout, side dual-ended readout, and triple-ended readout were 216.9 ps, 231.0 ps, and 203.6 ps, respectively.

1 April 2012 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
MNM Niu
M Niu
CKChien-Min Kao
Chien-Min Kao
JZJ Zhu
J Zhu
PXP Xiao
P Xiao
ALA Long
A Long
QXQiangqiang Xie
Qiangqiang Xie

12 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Xi ZhangXi Zhang
Xi Zhang
QXQiangqiang Xie
Qiangqiang Xie
SXSiwei Xie
Siwei Xie
XYXin Yu
Xin Yu
JXJianfeng Xu
Jianfeng Xu
QPQiyu Peng
Qiyu Peng
Portable radiation detectors are widely used in environmental radiation detection and medical imaging due to their portability feature, high detection efficiency, and large field of view. Lutetium-yttrium oxyorthosilicate (LYSO) is a widely used scintillator in gamma radiation detection. However, the structure and the arrangement of scintillators limit the sensitivity and detection accuracy of these radiation detectors. In this study, a novel portable sensor based on a monolithic LYSO ring was developed for the detection of environmental radiation through simulation, followed by construction and assessments. Monte Carlo simulations were utilized to prove the detection of gamma rays at 511 keV by the developed sensor. The simulations data, including energy resolutions, decoding errors, and sensitivity, showed good potential for the detection of gamma rays by the as-obtained sensor. The experimental results using the VA method revealed decoding errors in the energy window width of 50 keV less than 2°. The average error was estimated at 0.67°, a sufficient value for the detection of gamma radiation. In sum, the proposed radiation sensor appears promising for the construction of high-performance radiation detectors and systems.