Dumitru Dorin LUCACHE

Prof. Dr. Dumitru Dorin LUCACHE

Faculty of Electrical Engineering, Technical University Gheorghe Asachi, 700050 Iasi, Romania
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CGChiriac Gabriel
Chiriac Gabriel
Dumitru Dorin LUCACHEDumitru Dorin LUCACHE
Dumitru Dorin LUCACHE
CNCostică Nițucă
Costică Nițucă
Alin DragomirAlin Dragomir
Alin Dragomir
Seeram RamakrishnaSeeram Ramakrishna
Seeram Ramakrishna
The use of electric buses is increasing all over the world; this is due to the aim of limiting pollution in heavily urbanized areas. Using electric buses is one element of the desire to drop local pollution to zero emissions. The necessary electricity can be generated through centralized production, and in the case of electric buses, the pollution level is directly proportional to the amount of electricity produced. Their limited onboard power needs optimization, both in terms of traction and in auxiliary energy consumption. Heating in electric buses consumes the most energy from the auxiliaries, which can reduce the range of the vehicle up to a half, or more in the coldest days of the winter months. In this context, a precise estimation of heat loss and of the energy necessary for heating electric buses is crucial. Using the heat transfer theory, the heat balance method, and the U-value estimation, this article estimates the heat loss for a typical 12 m electric bus for a harsh winter day. Thermal simulations were made in order to estimate the heat flux through the structure of the bus (windows, walls, roof, and floor). Heat loss components were calculated in order to determine the most affected zones of the bus. The calculated data for the energy necessary to heat the bus were compared with the heating system data from an electric bus. By optimizing the necessary auxiliary energy consumption, the emissions at the source of electricity production will be significantly reduced.

12 August 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
AAAlexandru AlexandruViorelRusu
Alexandru AlexandruViorelRusu
CGCatalin Daniel GALATANU
Catalin Daniel GALATANU
GLGheorghe Livint
Gheorghe Livint
Dumitru Dorin LUCACHEDumitru Dorin LUCACHE
Dumitru Dorin LUCACHE
The main quality condition in street lighting is luminance distribution. During the carrying out of the literature, average luminance is the most important parameter to check. The standard BS EN 13201-3 imposes that average luminance must be calculated for the observer placed in the center of each circulating lane. As a consequence, according to these standards, the measurements can be done only on streets without traffic. Stopping the traffic on all lanes is very difficult. This paper proposes a solution for measuring the average luminance from outside the carriageway. The research was performed by simulations/calculations and was validated by field measurements. Imaging sensors were used to measure average luminance, while DIALux EVO 9.1 was used for the simulations. For symmetrical, opposite, and staggered lighting arrangements, average luminance measurements were performed with a digital camera positioned outside of the traffic area, with the equipment placed at the edge of the carriageway, giving similar results with standard measurements, with almost no difference. For single sided lighting arrangements, the differences became unacceptable. In this case, the paper proposes a correction function to calculate the average luminance for the observer placed on the carriageway, based on measurements with a digital camera placed outside the traffic area.

30 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GEORGE BALANGEORGE BALAN
GEORGE BALAN
NNNenninger Nenninger
Nenninger Nenninger
EZEnrique Ruiz Zúñiga
Enrique Ruiz Zúñiga
ESElena Serea
Elena Serea
Dumitru Dorin LUCACHEDumitru Dorin LUCACHE
Dumitru Dorin LUCACHE
ASAlexandru Salceanu
Alexandru Salceanu
The increasing complexity of modern automotive lighting systems requires advanced validation strategies that ensure both functional performance and regulatory compliance. This study presents a structured integration of Software-in-the-Loop (SiL) and Hardware-in-the-Loop (HiL) testing within a digital twin (DT) framework for validating headlamp systems. A gated validation process (G10–G120) is proposed, aligning each development phase with corresponding simulation stages from early requirements and concept validation to real-world scenario testing and continuous integration. A key principle of this approach is the adoption of a framework built upon the V-Cycle, adapted to integrate DT technology with SiL and HiL workflows. This architectural configuration ensures a continuous data flow between the physical system, the digital twin, and embedded software components, enabling real-time feedback, iterative model refinement, and traceable system verification throughout the development lifecycle. The paper also explores strategies for effective DT integration, such as digital twin-as-a-service, which combines virtual testing with physical validation to support earlier fault detection, streamlined simulation workflows, and reduced dependency on physical prototypes during lighting system development. Unlike the existing literature, which often treats SiL, HiL, and DTs in isolation, this work proposes a unified, domain-specific validation framework. The methodology addresses a critical gap by aligning simulation-based testing with development milestones and regulatory standards, offering a foundation for industrial adoption.

10 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
AAAlexandru AlexandruViorelRusu
Alexandru AlexandruViorelRusu
CGCatalin Daniel GALATANU
Catalin Daniel GALATANU
GLGheorghe Livint
Gheorghe Livint
Dumitru Dorin LUCACHEDumitru Dorin LUCACHE
Dumitru Dorin LUCACHE
This paper presents a study on the influence of the observer’s position in relation to the calculation surface. This is the initial observation of the research, respectively that the two standards consider the position of the observer differently. For these situations, two types of calculations were performed. For the first set of calculations, the software used was DIALux 4.13 as this software can perform calculations in line with the RP-08 standard. The second set of calculations was performed with a script that offers the possibility to change the observer’s position. The conclusion was that EN-13201 has a better approach, but both standards could be improved. The second case study refers to the influence of the longitudinal observer position in an average luminance calculation. If one considers RP-08 as a guideline for performing the calculations, the conclusions are that changing the distance from the observer to the calculation surface has absolutely no effect on the average luminance value. On the other hand, if European standards are used as a guideline, changing the distance (from the standardized 60 m, either closer to the calculation surface or further away) can influence the overall results in average luminance and uniformity. Taking into account the results of these two case studies, the conclusion is that both RP-08 and BS-EN 13201 should be updated so that the observer’s distance in relation to the calculation surface would be a variable dependent on the stopping distance calculated based on the speed limit of the road.

15 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
AAAbdoul-Razak ALI-TAGBA
Abdoul-Razak ALI-TAGBA
MBMazabalo Baneto
Mazabalo Baneto
Dumitru Dorin LUCACHEDumitru Dorin LUCACHE
Dumitru Dorin LUCACHE
The design of a high energy performance building requires an assessment of the various design options. Energy simulation offers interesting possibilities for clarifying the architect’s decisions at this level, especially in the initial design phases where the greatest opportunities for optimization lie. The aim of this work is to develop an approach for the evaluation and optimal use of energy simulation in the building design phases. To do this, EnergyPlus building simulation software was used to simulate the energy consumption of the Faculty of Electrical Engineering building at “Gheorghe Asachi” Technical University in Iasi, in order to identify the factors influencing energy consumption in buildings. The results of this study show that an increase in the cooling setpoint temperature from 22 °C to 28 °C in the roof construction can reduce operating temperatures by 14.2% and 20.0%, respectively. This optimization could significantly reduce the hours of thermal discomfort, in a ratio of 6.0 and 3.25, respectively. Consequently, optimizing parameters linked to design and the heating and cooling systems within the building makes it possible to achieve energy savings and ensure thermal comfort in buildings.

1 December 2019 in Light & Engineering
Verified
Journal Article
Closed access
CGCatalin Daniel GALATANU
Catalin Daniel GALATANU
MAMuhammad Ashraf
Muhammad Ashraf
Dumitru Dorin LUCACHEDumitru Dorin LUCACHE
Dumitru Dorin LUCACHE
DBDorin Beu
Dorin Beu
CCCalin Ciugudeanu
Calin Ciugudeanu
Optical utilization factor (OUF) is applied to architectural lighting, searching to obtain low light pollution. It is demonstrated that OUF could not be used for the assessment of light pollution, because the inter-reflections could not be neglected. DIALUX simulations and MATLAB original functions are used. Onsite measurements for illuminance and luminance are performed. It is demonstrated that OUF could be greater than one for the facade. For the small scale inter-reflections, a luminance gain is demonstrated. Due to this, the floodlighting could be reduced. The understanding about the light pollution assessment is changed, which is a major achievement. It means that a greater OUF don’t represent a lower light pollution, and also a facade could be more “visible” on lower level of floodlighting.