Zhensong Cao

Zhensong Cao


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
MSMing-Guo Sun
Ming-Guo Sun
ZCZhensong Cao
Zhensong Cao
JYJiyong Yao
Jiyong Yao
HMHong-Liang Ma
Hong-Liang Ma
YGYang-Wu Guo
Yang-Wu Guo
YWYi-Cheng Wu
Yi-Cheng Wu
A continuous-wave mid-infrared radiation from difference frequency generation by mixing a continuous-wave Ti: sapphire laser and a continuous-wave YAG laser in a 15 mm long BaGa4Se7 crystal is demonstrated for the first time. The tunable range from 3.15 to 7.92 μm was achieved by rotating the crystal to fulfill the type I phase-matching condition. A maximum DFG power of 1.41 μW was obtained at 5 μm. Meanwhile the experimental DFG power conversion efficiency was 20.2 μW/W2, with a length-normalized slope efficiency of 15.5 μW/cmW2. The conversion efficiency decreases rapidly from 50 μW/cmW2 at 3.15 μm to 1 μW/cmW2 at 7.92 μm. The wavelength acceptance bandwidth and the angular acceptance bandwidth were measured to be 16.4 cm−1 and 44′ for DFG at 5.1 μm, respectively.

19 March 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XLXingji Lu
Xingji Lu
YHYinbo Huang
Yinbo Huang
PWPengfei Wu
Pengfei Wu
DLDandan Liu
Dandan Liu
HMHongliang Ma
Hongliang Ma
ZCZhensong Cao
Zhensong Cao
Remote sensing of HDO and CH4 could provide valuable information on environmental and climatological studies. In a recent contribution, we reported a 3.53 μm distributed feedback (DFB) inter-band cascade laser (ICL)-based heterodyne radiometer. In the present work, we present the details of measurements and inversions of HDO and CH4 at Dunhuang, Northwest of China. The instrument line shape (ILS) of laser heterodyne radiometer (LHR) is discussed firstly, and the spectral resolution is about 0.004 cm−1 theoretically according to the ILS. Furthermore, the retrieval algorithm, optimal estimation method (OEM), combined with LBLRTM (Line-by-line Radiative Transfer Model) for retrieving the densities of atmospheric HDO and CH4 are investigated. The HDO densities were retrieved to be less than 1.0 ppmv, while the CH4 densities were around 1.79 ppmv from 20 to 24 July 2018. The correlation coefficient of water vapor densities retrieved by LHR and EM27/SUN is around 0.6, the potential reasons for the differences were discussed. Finally, in order to better understand the retrieval procedure, the Jacobian value and the Averaging Kernels are also discussed.

1 February 2020 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
HMHongliang Ma
Hongliang Ma
MSMingguo Sun
Mingguo Sun
SZShengbao Zhan
Shengbao Zhan
QZQilei Zhang
Qilei Zhang
SZShenlong Zha
Shenlong Zha
ZCZhensong Cao
Zhensong Cao

18 June 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FSFengjiao Shen
Fengjiao Shen
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
ZXZhengyue Xue
Zhengyue Xue
TTTu Tan
Tu Tan
ZCZhensong Cao
Zhensong Cao
Weidong ChenWeidong Chen
Weidong Chen
The time constant selected for lock-in amplification (LIA) has a crucial impact on observed line shapes in laser heterodyne spectroscopy, in particular in the case of ground-based remote monitoring of trace gas in the atmospheric column using laser heterodyne radiometer (LHR). Conventional simulation could not allow validation of LHR spectra measured in a real and complex atmospheric environment exhibiting large temporal and spatial variability (humidity, temperature, pressure, etc) that impact significantly the measured LHR spectra profiles. High-precision spectral measurement is thus crucial to avoid any spectral distortion resulting from the measurement. In this paper, the impact of LIA time constant on spectral line shape is investigated for LHR operating in continuous laser tuning mode, based on analysis of laboratory heterodyne spectra, in terms of signal-to-noise ratio (SNR), line width broadening, absorption depth and line shift. With respect to the given frequency scanning speed in continuous mode and to the halfwidth of the absorption feature to scan, a reasonable scanning time ΔTscan, the time needed for scanning laser frequency through the halfwidth ΔνHWHM of the absorption line, equal to or longer than 14 times of the LIA time constant τ is concluded in order to efficiently reduce the noise while without significant shift and distortion of the line shape. Experimental validation was carried out using a laser heterodyne absorption spectroscopy approach in the laboratory. Four different combinations of time constants τ and scanning time ΔTscan were used to record heterodyne spectra of a CH4 absorption line near 1242.00 cm−1 in continuous laser tuning mode. An optimal combination of a scanning time of 137 ms with a time constant of 1 ms was obtained. This optimal combination was used for ground-based measurements of CH4 and N2O in the atmospheric column by LHR. The extracted LHR spectrum is in good agreement with a referenced TCCON (Total Carbon Column Observing Network) FT-IR (Fourier-transform infrared) spectrum.

25 September 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZYZihao Yuan
Zihao Yuan
YHYinbo Huang
Yinbo Huang
XLXingji Lu
Xingji Lu
JHJun Huang
Jun Huang
QLqiang liu
qiang liu
ZCZhensong Cao
Zhensong Cao
A high sensitivity wavelength modulated reinjection off-axis integrated cavity output spectroscopy (WM-RE-OA-ICOS) experimental setup was built at a 2 μm band. On the basis of an off-axis integrated output spectroscopy (OA-ICOS), combined with an optical reinjection (RE) approach to improve signal intensity, and wavelength modulation spectroscopy (WMS) to improve the signal-to-noise ratio (SNR) of the system, the experimental study of trace CO2 with high sensitivity was carried out using the setup. The performance was compared and evaluated, and the results show that: Compared with the OA-ICOS, the wavelength modulated reinjection OA-ICOS enhanced the signal intensity by 6.3 times, and the SNR increased 7.2 times from 179 to 1288. The Allan variance results showed that the detection limit of the system is 0.35 ppm when the average system time is 230 s. The setup was used to measure the indoor CO2 concentration for a long time (22 h), and the measured results were in line with the actual concentration change. The proposed method shows good performance enhancement for the OA-ICOS system in trace gas measurements.

2 July 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
DLDandan Liu
Dandan Liu
YHYinbo Huang
Yinbo Huang
ZCZhensong Cao
Zhensong Cao
XLXingji Lu
Xingji Lu
DLDandan Liu
Dandan Liu
The instrument line shape (ILS), as a very important parameter, has a significant influence on the inversion of trace gas concentration. Different levels of ILS degradation for H2O, CO2, CH4, and CO gases were investigated, and the influence of ILS on the inversion of column-averaged dry air mole fractions (DMFs) was assessed. Our results indicate that the averages of XH2O, XCH4, and XCO with modulation efficiency (ME) amplitude values have a positive correlation, the correlation coefficients are 0.9925, 0.9968, and 0.9981 respectively, whereas the relationship between the average of XCO2 and ME is a negative correlation with 0.986 correlation coefficient. For a typical ILS degradation, a decrease of 5% in the modulation efficiency amplitude value results in the average of XCO2 changing by 0.744%, XCH4 and XH2O are less sensitive species, with average values of −0.206% and −0.464%, whereas XCO shows the strongest intraday variability with an average value of −0.238%. However, with a decrease of 2‰ in the phase error (PE) value, the average of XCO changed by −0.150%, XCO2 and XH2O almost coincided with the same average value of −0.141%, whereas XCH4 was the least sensitive species with an average value of −0.133%. At the same time, we measured the ILS for EM27/SUN spectrometers—the mean values of modulation efficiency amplitudes and phase errors were 0.9611 and 0.00593. Compared with standard values, the modulation efficiency amplitudes and the phase error deviations were 2.450% and 0.433%. During the observation period, the daily average of XCO2 ranged from 415.09 to 421.78 ppm. XCH4 ranged from 1.96 to 2.02 ppm with a mean of 1.982 ppm, and the daily average of XCO ranged from 0.118 to 0.157 ppm with a mean of 0.137 ppm. For the relationship between XCO2 and XCH4, the linear regression line shows a good correlation with the correlation coefficient R2 ≥ 0.5. Especially, for the correlation coefficient R2 = 0.82 on 8 October, our studies found a weak correlation in the variation of CO2 and CO during the observations. The correlation coefficient R2 ≥ 0.5 was only found on 30 September and 3 October. The trajectories dram at a height of 10 km give a hint of trace gas transport from the bay of western India, Bengal, and the Arabian Sea, whereas for the trajectories dram boundary layer height, trace gases were transported from southwest and east of China. These results provide a theoretical basis to understand the time and space distribution and the changes of greenhouse gas in the atmosphere as well as providing a theoretical basis for calculations of atmospheric radiation transmission.