Mohammed AL-SAADI

Dr. Mohammed AL-SAADI

Mobility, Logistics and Automotive Technology Research Centre, Vrije Universiteit Brussel, 1050 Brussels, Belgium
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2022 in IEEE Access
Verified
Journal Article
Open access
SDSanchari Deb
Sanchari Deb
MPMikko Pihlatie
Mikko Pihlatie
Mohammed AL-SAADIMohammed AL-SAADI
Mohammed AL-SAADI
Large scale adoption and public acceptance of Electric Vehicles (EVs) require availability of charging stations. Electrification of transport has been identified as the one of the significant factors that would increase the power demand. Management of charger load has become a matter of concern for the power system engineers. Uncoordinated charging can be detrimental to the smooth operation of the power grid. On the contrary, smart charging gives certain amount of control over the charging process with respect to the power grid. Hence, adaptivity of the charging process of EVs in smart charging assists to meet the needs of power system as well as EV users. A smart charger can adjust the charging power according to the power available from the grid, EV user needs, and also support the grid during emergency. Smart charging enables EVs to act as flexible grid resources thereby providing ancillary services to the grid in case of emergency. Further, EV users can gain significant financial benefits through smart timing of their charging against spot market prices. This work presents a comprehensive overview of smart charging thereby explaining its perception, impact, user acceptance, global status and pilot projects. Also, case studies highlighting the benefits of smart charging are presented. This detailed elucidation of smart charging will assist the researchers, and experts of power industry as well as transport to find research initiatives on smart charging at one platform thereby promoting adoption of smart charging.

10 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
Mohammed AL-SAADIMohammed AL-SAADI
Mohammed AL-SAADI
Josu OlmosJosu Olmos
Josu Olmos
AIAndoni Saez de Ibarra
Andoni Saez de Ibarra
Joeri Van MierloJoeri Van Mierlo
Joeri Van Mierlo
Maitane BerecibarMaitane Berecibar
Maitane Berecibar
Fast charging is an essential stakeholder concern for achieving a deeper penetration of Electric Vehicles (EVs), as optimizing the charging times of conventional vehicles is as yet a bottleneck to be solved. An important drawback of EV’s fast charging lies in the degradation suffered by the Li-ion Batteries (LIBs) at high charging currents. A deep understanding of the how these fast-charging activities affect the LIBs’ degradation is necessary in order to design appropriate fast charging stations and EV powertrains for different scenarios and contexts. In this regard, the present paper analyzes the effect of fast charging on Libs’ degradation under operation profiles from real driving cycles. Specifically, Battery Electric Buses (BEBs) driving profiles from three demos in European Cities (Gothenburg, Osnabrück and Barcelona) have been used in this analysis. In order to deduce the best practices for the design of the charging stations, different sizes for the chargers have been simulated, focusing on the analysis of the LIB degradation under each situation. Besides, for the design of the EV powertrain, different LIB sizes and LIB chemistries (Lithium Nickel Manganese Cobalt-NMC, Lithium Iron Phosphate-LFP, and Lithium Titanate Oxide-LTO) have also been proposed and compared in terms of LIB degradation. The results demonstrated that LTO batteries exhibited the lowest degradation, with capacity fade values under 1.5%/year in the nominal scenario (nominal charger and LIB sizes). As long as a full charging is ensured, reducing the fast charger size has been found to be a cost-effective measure, as the LTO degradation can be reduced at least to 1.21%/year. In addition, increasing the battery (BT) size has also been found to be a cost-effective approach for LTO batteries. In this case, it was found that for a 66% increase in capacity, the degradation can be reduced at least to 0.74%/year (more than 50% reduction). The obtained conclusions are seen as useful for the design of charging stations and EV’s BT systems that undergo fast charging.

15 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
Mohammed AL-SAADIMohammed AL-SAADI
Mohammed AL-SAADI
SBSharmistha Bhattacharyya
Sharmistha Bhattacharyya
PTPierre Van Tichelen
Pierre Van Tichelen
MMManuel Mathes
Manuel Mathes
JKJohannes Käsgen
Johannes Käsgen
Maitane BerecibarMaitane Berecibar
Maitane Berecibar
Battery Electric Buses (BEBs) are considerably integrated into cities worldwide. These buses have a strict schedule; thus, they could be charged in a very short time with a power level up to 600 kW. The high-power systems and short charging times imply special grid operation conditions that should be taken into account. Therefore, it is necessary to consider the influence of their charging infrastructure on the distribution system operation, especially near the charging point. This work presents two Use Cases (UCs) from two demos (Germany and the Netherlands) to investigate the impact of the slow and fast-chargers’ integrations on the power grid and environment. Fast-chargers up to 350 kW based on pantograph technology and slow-chargers up to 50 kW based on Combined Charging System Type 2 (CCS2) are used on the BEB line route and in the depot, respectively. The charging of BEBs with these solutions is studied here to investigate their impact on the grid in terms of power quality. It was found that the voltage variations due to fast-chargers terminal remain much below the EN50160 standard limit values i.e., ±10%. The obtained maximum Total Harmonic Voltage Distortion (THDv) value is 2.7%, with an average value of 1.3%, which is below the limit value of 8%, as per the standard EN 50160. Similarly, the individual harmonic currents were measured. The maximum value of total harmonic current distortion (THDI) is around 25%, with an average value of 3% only. As the average value of THDI is quite low, the harmonic current pollution is not a big concern for the installation at this time.

13 January 2022 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
Mohammed AL-SAADIMohammed AL-SAADI
Mohammed AL-SAADI
MMManuel Mathes
Manuel Mathes
JKJohannes Käsgen
Johannes Käsgen
KRKoffrie Robert
Koffrie Robert
MMMatthias Mayrock
Matthias Mayrock
Maitane BerecibarMaitane Berecibar
Maitane Berecibar
This work presents three demos, which include Electric Buses (EBs) from four various brands with lengths of 12 m and 18 m and an Electric Truck (E-truck) for refuse collection. The technical operation of these EVs were analyzed to implement further operational cost optimization on the demo vehicles. The Electric Vehicles (EVs) were tested against superfast-charging solutions based on Pantograph (Type A & Type B) on the route lines (and depots) and based on Combined Charging System Type 2 (CCS2, Combo2) from various brands to validate the interoperability among several vendors and support further EV integration with more affordable solutions. The optimization includes the calculation of the EBs’ consumption at various seasons and under various operating conditions in order to use optimum battery system design, heating system, optimum EB fleet operation and size and to find the charging solutions properly. The results showed that the EB consumption increases in some cases by 64.5% in wintertime due to heating systems, and the consumption in urban areas is more than that on the route lines outside cities. In the E-truck demo, where the electric heater was replaced with a heat-pump to optimize the energy consumption, it was found that the consumption of the heat-pump is about half of the electric heater under certain operating conditions. Under strict EB schedule, Pantograph charging solutions with power ratings of 300–600 kW have been adopted to charge the batteries of the EBs within 4–10 min. In order to minimize the cumulative costs of energy, (pantograph) charging infrastructure depreciation and battery degradation, as well as depot charging (at the bus operator’s depot), was adopted with a power level of 50–350 kW based on CCS2 and pantograph.

25 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Mohammed AL-SAADIMohammed AL-SAADI
Mohammed AL-SAADI
BPBartosz Patkowski
Bartosz Patkowski
MZMaciej Zaremba
Maciej Zaremba
AKAgnieszka Karwat
Agnieszka Karwat
MPMateusz Pol
Mateusz Pol
Maitane BerecibarMaitane Berecibar
Maitane Berecibar
This work presents a real-life demonstration of 23 heavy-duty (HD) public electric buses (e-buses) in Jaworzno, Poland, with three lengths: 8.9 m, 12 m, and 18 m. The e-bus demo is based on the development of baseline e-buses to optimize the operational cost based on technical optimization. The demo aims to switch public transportation from internal combustion engine vehicles (ICEVs) to electric ones to minimize CO2 emissions. The e-buses are equipped with standard charging solutions, which are plug-in charging with Combined Charging System Type 2 (CCS2, Combo 2) and pantograph-up (Type B). The CCS2 solution is used for overnight slow/normal charging (NC) in the depot of the e-bus operator, whereas the pantograph charging solutions are installed along the e-buses routes and used for fast charging (FC) when the e-buses are stopped for a short time. In Jaworzno, there are 20 chargers with CCS2 in the depot of the e-bus operator and 12 pantograph-up (Type B solution) fast-charging stations. This work studies the technical operations and operational costs of the e-bus fleet, and the impact of the NC and FC solutions on the Li-ion battery packs and on the grid. The uncoordinated/standard and coordinated charging (smart charging) based on load shifting were investigated to study the impact of e-bus fleet integration on the distribution grid. The exploited data in this study were collected from the data logger devices, which are installed on the e-buses and record over 46 signals. Data from over one year were collected, and some sample data were processed and analyzed to study the technical and economic operations of the e-bus fleet.

25 August 2020 in Engineering and Technology Journal
Verified
Journal Article
Open access
PDF file
AJAbdullateef Jadallah
Abdullateef Jadallah
Mohammed AL-SAADIMohammed AL-SAADI
Mohammed AL-SAADI
SHSaifalddeen Hussien
Saifalddeen Hussien
In this paper, the hybrid PVT double pass system with a mixed-mode solar dryer type under forced convection has been designed, fabricated and installed for drying crops. The dryer was tried by drying 300 grams of banana slices in the air temperature of dryer range from 43.2 to 60.2°C. The initial moisture rate of banana was about 78% and the most dropped in moisture content was from 78% to 33% after 8 hours of the drying process. The banana slices are distributed in two identical trays and it was noticed that the most and least decreasing in weight of banana samples was from 150 to 48 gram and from 150 to 55 gram in lower and upper tray respectively, when the mass flow rate as 0.031 and 0.017 kg/s, which means that the high reduction was 68% of weight banana at a high mass flow rate of airflow. The critical parameter such as temperature distribution of the PVT with dryer room, useful heat gain, and thermal efficiency are computed by using the MATLAB 2015b program built for this purpose. The optimum useful heat gain and thermal efficiency were reached 423.7 and 52.98% respectively when the solar radiation 1190 and the mass flow rate of 0.031 kg/s. This paper proposes a developed numerical and experimental design of a hybrid Photovoltaic-Thermal (PVT) double-pass counter-flow system connected with the mixed-mode solar dryer system. The mixed-mode solar dryer considers the most efficient mode because it has two heat sources, from solar radiation and the hot airflow which is supplied by the PVT system. The PVT system is often unused for drying applications; therefore, the whole proposed PVT solar system in this work is utilized for drying applications. This system is not only massive fuel savings, but also crucial to improve the quality of the dried product in terms of color, aroma, and taste. To verify the effectiveness and robustness of the proposed system, the system is utilized to dry 300g of slices of banana, where the obtained range of air temperature is from 43.2 to 60.2°C. The slices of banana are distributed identically between upper and lower trays. The initial moisture rate of banana was about 78%, and the most dropped in moisture content was from 78% to 28.12% in the lower tray at 0.031kg/s after 8 hours of the drying process. It was noticed that the most and least decreasing in weight of banana samples was from 150 to 48g and from 150 to 55g in lower and upper tray, respectively, at 0.031 and 0.017 kg/s mass flow rate. This gives an indication that the highest reduction was 68% of banana weight at a high mass flow rate of airflow. The critical parameter such as temperature distribution of the PVT with dryer room, useful heat gain, and thermal efficiency are computed by using the MATLAB 2015b program which is built for this purpose. The highest heat gain and thermal efficiencies were 423.7 and 52.98%, respectively, at 1:00 PM when the mass flow rate 0.031 kg/s.