Aims: The field of conduction system pacing (CSP) is evolving, and our aim was to obtain a contemporary picture of European CSP practice. Methods and results: A survey was devised by a European CSP Expert Group and sent electronically to cardiologists utilizing CSP. A total of 284 physicians were invited to contribute of which 171 physicians (60.2%; 85% electrophysiologists) responded. Most (77%) had experience with both His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP). Pacing indications ranked highest for CSP were atrioventricular block (irrespective of left ventricular ejection fraction) and when coronary sinus lead implantation failed. For patients with left bundle branch block (LBBB) and heart failure (HF), conventional biventricular pacing remained first-line treatment. For most indications, operators preferred LBBAP over HBP as a first-line approach. When HBP was attempted as an initial approach, reasons reported for transitioning to utilizing LBBAP were: (i) high threshold (reported as >2 V at 1 ms), (ii) failure to reverse bundle branch block, or (iii) > 30 min attempting to implant at His-bundle sites. Backup right ventricular lead use for HBP was low (median 20%) and predominated in pace-and-ablate scenarios. Twelve-lead electrocardiogram assessment was deemed highly important during follow-up. This, coupled with limitations from current capture management algorithms, limits remote monitoring for CSP patients. Conclusions: This survey provides a snapshot of CSP implementation in Europe. Currently, CSP is predominantly used for bradycardia indications. For HF patients with LBBB, most operators reserve CSP for biventricular implant failures. Left bundle branch area pacing ostensibly has practical advantages over HBP and is therefore preferred by many operators. Practical limitations remain, and large randomized clinical trial data are currently lacking.
Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular complexes (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT and PVC. Multicentre registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. Consecutive patients undergoing Bi-RFA at 16 European centres for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. Between March 2021 and August 2024, 91 patients underwent 94 Bi-RFA procedures (74 males, age 62 ± 13, and prior Uni-RFA range 1–8). Indications were recurrence of PVC (n = 56), VT (n = 20), electrical storm (n = 13), or PVC-triggered ventricular fibrillation (n = 2). Procedural time was 160 ± 73 min, Bi-RFA time 426 ± 286 s, and mean Uni-RFA time 819 ± 697 s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients and suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%), no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, atrioventricular block, and arteriovenous fistula. Follow-up lasted 7 ± 8 months. Nineteen patients (61%) remained VT free. ≥80% PVC burden reduction was achieved in 45 (78%). These real-world registry data indicate that Bi-RFA appears safe, is feasible, and is effective in the majority of patients with VT/PVC.
Background: Circumferential pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is a standard of care intervention for patients with symptomatic atrial fibrillation (AF). During follow-up, a substantial number of patients need a redo procedure due to reconnections on the basis of insufficient non-transmural ablation lesions. High-power short-duration ablation (HPSD) is expected to create efficient lesions while causing fewer complications than in conventional RFA settings. The aim of this study was to compare one-year outcome data of very HPSD (90 Watt, 4 s) to a strategy using 50 Watt HPSD ablation guided by the CLOSE protocol using the Ablation Index (AI), an arbitrary unit composed of power, contact force and ablation time. Methods: We retrospectively analyzed short and long-term (median follow-up 23.2 ± 9.9 months) outcome data from 52 patients that were scheduled for first-do-symptomatic PVI. A very HPSD ablation protocol with 90 Watt and a 4 s duration cut-off was compared to an HPSD CLOSE approach (50 Watts; AI 550 at the anterior LA wall; AI 400 at the posterior LA wall, the roof and the floor) in terms of freedom from AF recurrence in a long-term electrocardiogram (ECG) over a five days surveillance period. To gain an impression of the subjective sense of wellbeing, the Atrial Fibrillation Effects on QualiTy-of-Life (AFEQT) score was recorded. Results: Overall freedom from AF was found in 81% (90 W 4 s) vs. 87.5% (50 W), (p = 0.52). There were 3 AF recurrences during the blanking period (90 W 4 s) vs. 1 (50 W). Within each population, one patient was scheduled for a redo-PVI-procedure. The AFEQT score was in favor of the 90 Watt 4 s approach (86.1 vs. 77.5; p = 0.37). Conclusion: Within our relatively small studied population, we found hints that in addition to shortening ablation times and radiation exposure without significantly increasing the rate of relevant intraprocedural complications, very high power short-duration ablation (90 W 4 s) provides comparable efficacy rates after one year.
The current gold standard in device therapy for advanced heart failure (HF), which has been firmly established in HF management for more than 25 years, is classical biventricular pacing (BiV-CRT). In the last decade, a new pacing modality called conduction system pacing (CSP) has emerged as a variant for advanced cardiac device therapy. It provides pacing with preserved intrinsic cardiac activation by direct stimulation of the specific cardiac conduction system. The term CSP integrates the modalities of HIS bundle pacing (HBP) and left bundle branch area pacing (LBBAP), both of which have provided convincing data in smaller randomized and big non-randomized studies for the prevention of pacemaker-induced cardiomyopathy and for providing effective cardiac resynchronization therapy in patients with classical CRT-indication (primary approach or after failed CRT). Recent American guidelines proposed the term “cardiac physiological pacing” (CPP), which summarizes CSP including left ventricular septal pacing (LVSP), a technical variant of LBBAP together with classical BiV-CRT. The terms HOT-CRT (HIS-optimized CRT) and LOT-CRT (LBBP-optimized CRT) describe hybrid technologies that combine CSP with an additional coronary-sinus electrode, which is sometimes useful in patients with advanced HF and diffuse interventricular conduction delay. If CSP continues providing promising data that can be confirmed in big, randomized trials, it is likely to become the new gold standard for patients with an expected high percentage of pacing (>20%), possibly also for cardiac resynchronization therapy. CSP is a sophisticated new treatment option that has the potential to raise the term “cardiac resynchronization therapy” to a new level. The aim of this review is to provide basic technical, anatomical, and functional knowledge of these new pacemaker techniques in order to facilitate the understanding of the different modalities, as well as to provide an up-to-date overview of the existing randomized and non-randomized evidence, particularly in direct comparison to right ventricular and classical biventricular pacing.
Atrial Fibrillation (AF) and Heart Failure (HF) are closely linked to each other, as each can be either the cause of or the result of the other. Successfully treating one of the two entities means laying the basis for treating the other one as well. Management of patients with AF and HF can be challenging and should primarily adhere to available guidelines. Concerning AF, medication is limited and causes many side effects, leading to low medical adherence. Several smaller studies, summarized in a big meta-analysis, provide evidence that ablation of AF in HF patients is crucial for improving quality of life, reducing HF hospitalizations, and reducing death, provided the LVEF is at least 25% or higher. In advanced HF, alternative treatment options (including assist devices, heart transplant) might still be the better option. Early rhythm control should be taken into consideration, as there is evidence that it is associated with better cardiovascular outcome.
The Arrhythmia Working Group of the Austrian Society of Cardiology (ÖKG) has set the goal of systematically structuring and organizing the acute care of patients with ventricular arrhythmias (VA), i.e. ventricular tachycardia (VT) or ventricular fibrillation (VF) in Austria. Within a consensus paper, national recommendations on the basic diagnostic work-up of VA (12-lead ECG, medical history, family history, laboratory analyses, echocardiography, search for reversible causes, ICD interrogation), as well as further medical treatment and therapeutic measures (indication of coronary angiography, ablation therapy) are established.