Martin Martinek

Prof. Dr. Martin Martinek

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2023 in European Heart Journal
Verified
Journal Article
Open access
PDF file
RTRoland Richard Tilz
Roland Richard Tilz
VSVanessa Schmidt
Vanessa Schmidt
HPHelmut Pürerfellner
Helmut Pürerfellner
PMPhilippe Maury
Philippe Maury
KCK R J Ulian Chun
K R J Ulian Chun
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0–60) days and 21 (15, 29.5; range: 2–63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0–42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high. Summary of the POTTER-AF study results. CI, confidence interval; OR, odds ratio.

1 January 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
Christian-H HeegerChristian-H Heeger
Christian-H Heeger
CSChristian Sohns
Christian Sohns
APAlexander Pott
Alexander Pott
AMAndreas Metzner
Andreas Metzner
OIOsamu Inaba
Osamu Inaba
RTRoland Richard Tilz
Roland Richard Tilz
Background: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. Methods: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. Results: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was −49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. Conclusions: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03645577. Graphic A graphic abstract is available for this article.

1 August 2025 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
Shaojie ChenShaojie Chen
Shaojie Chen
SNSanjiv M. Narayan
Sanjiv M. Narayan
SBSerge Boveda
Serge Boveda
KNKars Neven
Kars Neven
MRMartin H. Ruwald
Martin H. Ruwald
HPHelmut Purerfellner
Helmut Purerfellner
Pulsed field ablation (PFA) has been developed as a largely nonthermal ablation technology with a unique biophysical profile to treat atrial fibrillation. Existing evidence has shown that PFA offers a safe and efficient atrial fibrillation ablation procedure. Among different PFA technologies, the pentaspline FARAPULSE system has been the most extensively used and investigated; however, notable variability exists in workflow, fluoroscopy time, and lesion durability. While innovations such as 3-dimensional electroanatomic mapping systems and intracardiac echocardiography can enhance procedural precision in catheter ablation, fluoroscopy remains the primary imaging modality for guiding pentaspline PFA in many electrophysiology labs worldwide. This is particularly true in centers where limitations in cost, infrastructure, or training may preclude the routine use of advanced imaging technologies. This article summarizes general practical considerations and presents a primarily fluoroscopy-based, refined workflow developed by a group of experts. The goal is to provide a procedural foundation and practical guide for using the pentaspline FARAPULSE PFA system in atrial fibrillation ablation procedures. Developing a fluoroscopy-based practical guide would: (1) Democratize access to PFA technology, enabling safe and effective implementation across a broader range of clinical settings, including those without intracardiac echocardiography or 3-dimensional mapping support; (2) Reduce procedural heterogeneity by offering reproducible best practices; (3) Facilitate meaningful intercenter comparisons of procedural efficacy and safety, aiding in the identification of optimal approaches and improving the quality of clinical data for ongoing research, registries, and real-world performance monitoring of PFA technologies; and (4) Ultimately improve patient outcomes through standardized, accessible, and evidence-based practices.

27 September 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
PFPiotr Futyma
Piotr Futyma
ASArian Sultan
Arian Sultan
ŁZŁukasz Piotr Zarębski
Łukasz Piotr Zarębski
DIDr. Med. Guram Imnadze
Dr. Med. Guram Imnadze
VMVera Maslova
Vera Maslova
JCJulian K R Chun
Julian K R Chun
Advanced ablation strategies are needed to treat ventricular tachycardia (VT) and premature ventricular complexes (PVC) refractory to standard unipolar radiofrequency ablation (Uni-RFA). Bipolar radiofrequency catheter ablation (Bi-RFA) has emerged as a treatment option for refractory VT and PVC. Multicentre registry data on the use of Bi-RFA in the setting of refractory VT and PVC are lacking. The aim of this Bi-RFA registry is to determine its real-world safety, feasibility, and efficacy in patients with refractory VT/PVC. Consecutive patients undergoing Bi-RFA at 16 European centres for recurring VT/PVC after at least one standard Uni-RFA were included. Second ablation catheter was used instead of a dispersive patch and was positioned at the opposite site of the ablation target. Between March 2021 and August 2024, 91 patients underwent 94 Bi-RFA procedures (74 males, age 62 ± 13, and prior Uni-RFA range 1–8). Indications were recurrence of PVC (n = 56), VT (n = 20), electrical storm (n = 13), or PVC-triggered ventricular fibrillation (n = 2). Procedural time was 160 ± 73 min, Bi-RFA time 426 ± 286 s, and mean Uni-RFA time 819 ± 697 s. Elimination of clinical VT/PVC was achieved in 67 (74%) patients and suppression of VT/PVC in a further 10 (11%) patients. In the remaining 14 patients (15%), no effect on VT/PVC was observed. Three major complications occurred: coronary artery occlusion, atrioventricular block, and arteriovenous fistula. Follow-up lasted 7 ± 8 months. Nineteen patients (61%) remained VT free. ≥80% PVC burden reduction was achieved in 45 (78%). These real-world registry data indicate that Bi-RFA appears safe, is feasible, and is effective in the majority of patients with VT/PVC.

16 January 2022 in American Heart Journal
Verified
Journal Article
Open access
DLDirk Von Lewinski
Dirk Von Lewinski
Norbert TripoltNorbert Tripolt
Norbert Tripolt
Harald SourijHarald Sourij
Harald Sourij
PPPeter N Pferschy
Peter N Pferschy
AOAbderrahim Oulhaj
Abderrahim Oulhaj
DSDaniel Scherr
Daniel Scherr
Sodium glucose cotransporter 2 (SGLT2) have proven profound positive effects in heart failure with reduced ejection fraction (HFrEF). These effects are independent from the presence of diabetes. Metabolic effects, antiinflammatory, and antifibrotic properties are discussed as underlying mechanisms. Despite a strong correlation of ventricular arrhythmias with HFrEF, the impact of ertugliflozin on the ventricular arrhythmic burden has not been investigated, yet. Therefore, the Ertugliflozin to Reduce Arrhythmic burden in ICD ± CRT patientS (ERASe) trial was designed to investigate the efficacy and safety of ertugliflozin in patients with reduced and midrange ejection fraction (EF) with or without diabetes. METHODS: Within a multicentre, national, randomized, double-blind, placebo-controlled, phase 3b trial we aim to enrol a total of 402 patients across Austria. Patients with reduced or midrange EF and ICD ± CRT therapy >3 months and previous ventricular tachycardia (at least 10 documented VT episodes within the last 12 months) are randomized in a 1:1 ratio to ertugliflozin (5 mg once daily orally administered) or matching placebo. The primary endpoint of the ERASe trial is to investigate the impact of ertugliflozin on total burden of ventricular arrhythmias. Further objectives will include number of therapeutic interventions of implanted devices, atrial fibrillation and heart failure biomarkers. CONCLUSION: The ERASe trial will be the first trial to test ertugliflozin in heart failure patients with nonpreserved ejection fraction and ongoing ICD ± CRT therapy regardless of their diabetic status. The ERASe trial may therefore extend the concept of SGLT2 inhibition to improve cardiac remodelling, including reduced arrhythmic burden. Trial registration Identifier EudraCT Nr. 2020-002581-14 / ClinicalTrials.gov Identifier: NCT04600921.

21 March 2011 in EP Europace
Verified
Journal Article
Open access
PDF file
MAMarco Alings
Marco Alings
EVElisa Vireca
Elisa Vireca
DBDirk Bastian
Dirk Bastian
AWAlexander Jacques Wardeh
Alexander Jacques Wardeh
CNC. Nimeth
C. Nimeth
FIfor the AUTOMATICITY Study Investigators
for the AUTOMATICITY Study Investigators
Follow-up of the ever-increasing numbers of patients with implantable cardiac devices places a heavy burden on clinical departments. Device automaticity may alleviate the follow-up burden by minimizing the time for physician involvement. The aim of the prospective, multicentre AUTOMATICITY registry was to examine the performance of a subset of programmed automatic algorithms during patient follow-up and their acceptance by implanting physicians. The clinical use of automatic algorithms from the InsigniaTM pacemakers (PM; Boston Scientific, St Paul, MN, USA) was evaluated: atrial and ventricular AutoSense (sensitivity adjustment), ventricular Automatic Capture (threshold verification and output setting), AutoLifeStyleTM (sensor settings adjustment). The objective of the study was to assess the reprogramming rates within 12 months of implant, the reasons for reprogramming and relationship to adverse events. A total of 960 patients were enrolled in the study. The proportion of patients free from any algorithm reprogramming at 12 months was 86.1%. A total of 2736 algorithms were activated at enrolment, with 156 (5.7%) being reprogrammed in 115 patients at 12 months for any reason. Forty-nine reprogrammings (1.8%) were unintentional or related to changes in device settings such that the algorithm was no longer available, 33 (1.2%) were due to suspected sensing issues, and 22 (0.8%) were assumed related to the algorithm. The individual 12-month reprogramming-free rates were: ventricular AutoSense 94.3%, Atrial AutoSense 93.3%, AutoLifeStyleTM 93.9%, and Automatic Capture 95.9%. The results of the AUTOMATICITY registry show that automatic measurement of key settings and automatic adjustment to optimal programming is feasible and safe. The simplicity of PM follow-up and avoidance of frequent reprogramming may contribute to a more effective use of hospital time and resources.