Rafael Rocha Pacheco

Dr. Rafael Rocha Pacheco

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Gabriela de Alencar Pinto MagalhãesGabriela de Alencar Pinto Magalhães
Gabriela de Alencar Pinto Magalhães
MFMay Anny Alves Fraga
May Anny Alves Fraga
IAIsaac Jordão de Souza Araújo
Isaac Jordão de Souza Araújo
RPRafael Rocha Pacheco
Rafael Rocha Pacheco
RPRafael Rocha Pacheco
Rafael Rocha Pacheco
Regina PUPPIN-RONTANIRegina PUPPIN-RONTANI
Regina PUPPIN-RONTANI
After bleaching, enamel surfaces are damaged, contributing to erosion and tooth sensitivity. Although fluoride is used after bleaching to try and revert alterations, it is not capable of repairing tooth structure. This study compared the effect of a self-assembly peptide (P11-4), with and without fluoride, and sodium fluoride (NaF 2%) on the Knoop microhardness (KHN) and surface roughness (Ra (μm)) of bleached enamel with an in-office bleaching regimen. Enamel blocks of bovine teeth (5 × 5 × 2 mm) with standardized surface hardness were bleached with 35% carbamide peroxide, following the manufacturer’s instructions. The teeth were randomly divided into the following groups (n = 7) according to post-bleaching treatment: no treatment (negative control) (C-); 2% NaF (NaF); Curodont™ Repair (Repair); and Curodont™ Protect (Protect). Specimens were stored in artificial saliva at 37 °C. To evaluate the effect of the post-bleaching treatments, KHN and Ra were measured before bleaching (baseline) and 24 h and 7 days after bleaching. Data were submitted to repeated measures ANOVA and Bonferroni tests (α = 0.05). There were significant interactions between the study factors (p = 0.001). After 7 days, Repair (572.50 ± 79.04) and Protect (583.00 ± 74.76) specimens showed increased surface KHN, with values higher than the NaF (465.50 ± 41.50) and C- (475.22 ± 58.95) baseline values. There was no significant difference in KHN at 24 h among groups (p = 0.587). At 24 h after bleaching, Repair was significantly different from all groups (p < 0.05). Repair showed the lowest Ra (μm) values (0.133 ± 0.035). After seven days, there was no significant difference in Ra values among groups when compared to the baseline. The use of P11-4-based materials after bleaching resulted in the fastest recovery to baseline enamel properties.

27 March 2025 in The Journal of the American Dental Association
Verified
Journal Article
Closed access
JSJoão Vitor Do Nascimento Santos
João Vitor Do Nascimento Santos
Gabriela de Alencar Pinto MagalhãesGabriela de Alencar Pinto Magalhães
Gabriela de Alencar Pinto Magalhães
JLJuan Vitor Costa Leite
Juan Vitor Costa Leite
RPRafael Rocha Pacheco
Rafael Rocha Pacheco
Regina PUPPIN-RONTANIRegina PUPPIN-RONTANI
Regina PUPPIN-RONTANI
RLRenally Bezerra Wanderley Lima
Renally Bezerra Wanderley Lima

Verified
Journal Article
Open access
PDF file
Gabriela de Alencar Pinto MagalhãesGabriela de Alencar Pinto Magalhães
Gabriela de Alencar Pinto Magalhães
JTJoshua J Thomson
Joshua J Thomson
CSCristine Smoczer
Cristine Smoczer
EKEric Krukonis
Eric Krukonis
AMAdaias O. Matos
Adaias O. Matos
Regina PUPPIN-RONTANIRegina PUPPIN-RONTANI
Regina PUPPIN-RONTANI
This study investigated the influence of incorporating Biosilicate® on the physico-mechanical and biological properties of glass ionomer cement (GIC). This bioactive glass ceramic (23.75% Na2O, 23.75% CaO, 48.5% SiO2, and 4% P2O5) was incorporated by weight (5%, 10%, or 15%) into commercially available GICs (Maxxion R and Fuji IX GP). Surface characterization was made by SEM (n = 3), EDS (n = 3), and FTIR (n = 1). The setting and working (S/W time) times (n = 3) and compressive strength (CS) were analyzed (n = 10) according to ISO 9917-1:2007. The ion release (n = 6) was determined and quantified by ICP OES and by UV-Vis for Ca, Na, Al, Si, P, and F. To verify cell cytotoxicity, stem cells from the apical papilla (SCAP) were exposed to eluates (n = 3, at a ratio of 1.8 cm2/mL) and analyzed 24 h post-exposure. Antimicrobial activity against Streptococcus mutans (ATCC 25175, NCTC 10449) was analyzed by direct contact for 2 h (n = 5). The data were submitted for normality and lognormality testing. One-way ANOVA and Tukey’s test were applied for the working and setting time, compressive strength, and ion release data. Data from cytotoxicity and antimicrobial activity were submitted for Kruskal–Wallis’ testing and Dunn’s post hoc test (α = 0.05). Among all experimental groups, only those with 5% (wt) of Biosilicate® showed better surface quality. Only M5% showed a comparable W/S time to the original material (p = 0.7254 and p = 0.5912). CS was maintained for all Maxxion R groups (p > 0.0001) and declined for Fuji IX experimental groups (p < 0.0001). The Na, Si, P, and F ions released were significantly increased for all Maxxion R and Fuji IX groups (p < 0.0001). Cytotoxicity was increased only for Maxxion R with 5% and 10% of Biosilicate®. A higher inhibition of S. mutans growth was observed for Maxxion R with 5% of Biosilicate® (less than 100 CFU/mL), followed by Maxxion R with 10% of Biosilicate® (p = 0.0053) and Maxxion R without the glass ceramic (p = 0.0093). Maxxion R and Fuji IX presented different behaviors regarding Biosilicate® incorporation. The impacts on physico-mechanical and biological properties were different depending on the GIC, but therapeutic ion release was increased for both materials.

30 May 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
LMLara Christie Monteiro
Lara Christie Monteiro
RPRafael Rocha Pacheco
Rafael Rocha Pacheco
MSMichael Sekula
Michael Sekula
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
DDDavid Donatelli
David Donatelli
GSGrace M De Souza
Grace M De Souza

31 October 2019 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
AMAhmad Maalhagh-Fard
Ahmad Maalhagh-Fard
RPRafael Rocha Pacheco
Rafael Rocha Pacheco
KGKaranjot Gill
Karanjot Gill
WWWarren Charles Wagner
Warren Charles Wagner
Objectives: The aim of this study was to evaluate the effects of using different diameters of parallel cast posts with, or without ferrule, on the overall fracture resistance of Cast Post and Core (CPC).Material and methods: Forty (40) endodontically treated human maxillary central incisors were divided into four groups (n=10): [F1] 1.0 mm diameter post with ferrule; [NF1] 1.0 mm diameter cast post without ferrule; [F1.5] 1.5 mm diameter cast post with ferrule; [NF1.5] 1.5 mm diameter post without ferrule. For all teeth, the post space (9.0 mm, in depth) was prepared using ParaPostTM drill. CPC using base metal alloy were fabricated and were cemented using resin modified glass ionomer (RMGI) cement along with the PFM crowns. A universal testing machine (Instron) was used to apply horizontal force perpendicular to the long axis of the tooth at the center of lingual surface, until catastrophic failure. Data was submitted to two-way ANOVA and Scheffé tests (P<0.05).Results: Both post diameter and ferrule statistically affected the maximum load at fracture (P=0.004 and P=0.013, respectively). The highest mean values were observed for samples with ferrule and wider post size (490N), while the lowest were observed for samples without ferrule and narrower post size (254N). There was no relationship between the presence of a ferrule and post size (P=0.937).Conclusions: For endodontically treated teeth with no ferrule, a wider-diameter cast post increases fracture resistance of a CPC and PFM crown procedure.

5 December 2022 in Brazilian Dental Journal
Verified
Journal Article
Open access
MGMaurício Bottene Guarda
Maurício Bottene Guarda
RPRafael Rocha Pacheco
Rafael Rocha Pacheco
ISIsaias Donizeti Silva
Isaias Donizeti Silva
WBWilliam Brandt
William Brandt
MSMário Alexandre Coelho Sinhoreti
Mário Alexandre Coelho Sinhoreti
RVRafael Pino Vitti
Rafael Pino Vitti
Resumo O objetivo neste estudo foi avaliar o efeito da direção da corrente elétrica na resistência da união resina composta-dentina usando três sistemas adesivos. Dentes molares humanos foram distribuídos de acordo com o sistema adesivo (dois passos autocondicionante - Clearfil SE Bond, Kuraray [CSE]; e um passo autocondicionante - Single Bond Universal, 3M ESPE [SBU]; e dois passos convencional - Adper Single Bond 2, 3M ESPE [SB2]), a direção da corrente elétrica (sem corrente elétrica - controle, correntes elétricas direta e reversa - 35µA) e tempo de armazenamento (24h - imediato e 6 meses). Blocos de resina composta (Filtek Z350XT, 3M ESPE) foram aderidos à dentina. Amostras de dentina-resina foram produzidas e armazenadas em água destilada a 37ºC por 24 horas e 6 meses para o teste de resistência da união à microtração (µTBS) (n = 10; ~12 palitos por dente). Os padrões de fratura foram analisados em estereomicroscópio e classificados em falhas coesiva na dentina, coesiva na resina, adesiva ou mista. A penetração do adesivo na dentina e a formação da camada híbrida foram avaliadas em microscópio eletrônico de varredura (MEV). Os dados foram submetidos à ANOVA três fatores seguidos pelo teste post hoc de Tukey (α = 0,05). Não houve diferenças na µTBS quando os sistemas adesivos foram aplicados sob as correntes elétricas direta e reversa, mas ambas as correntes elétricas aumentaram a µTBS para todos os sistemas adesivos. SBU apresentou os menores valores de µTBS para o grupo controle em ambos os tempos de armazenamento e para a corrente elétrica direta em 6 meses de armazenamento. Falhas adesivas foram mais frequente em todos os grupos. A corrente elétrica formou longos tags resinosos para todos os sistemas adesivos. O armazenamento por 6 meses não diminuiu significativamente os valores de µTBS. Ambos os sentidos da corrente elétrica (cargas positivas e negativas) a 35µA podem aumentar a µTBS dos sistemas adesivos testados à dentina.