Atherosclerosis affects human health in many ways, leading to disability or premature death due to ischemic heart disease, stroke, or limb ischemia. Poststenotic blood flow disruption may also play an essential role in artery wall impairment linked with hemolysis related to shear stress. The maximum shear stress in the atherosclerotic plaque area is the main parameter determining hemolysis risk. In our work, a 3D internal carotid artery model was built from CT scans performed on patients qualified for percutaneous angioplasty due to its symptomatic stenosis. The obtained stenosis geometries were used to conduct a series of computer simulations to identify critical parameters corresponding to the increase in shear stress in the arteries. Stenosis shape parameters responsible for the increase in shear stress were determined. The effect of changes in the carotid artery size, length, and degree of narrowing on the change in maximum shear stress was demonstrated. Then, a correlation for the quick initial diagnosis of atherosclerotic stenoses regarding the risk of hemolysis was developed. The developed relationship for rapid hemolysis risk assessment uses information from typical non-invasive tests for treated patients. Practical guidelines have been developed regarding which stenosis shape parameters pose a risk of hemolysis, which may be adapted in medical practice.
Background/Objective: Atherosclerosis is becoming increasingly common in modern society. Owing to the increasing number of complex angioplasty procedures, there is an increasing need for training in cases where the risk of periprocedural complications is high. Methods: A procedure was developed to obtain three-dimensional (3D) models and printing of blood vessels. The mechanical and optical properties of the printed materials were also examined. Angioplasty and stent implantation were tested, and the phantom was compared with the clinical data of patients who underwent interventional treatment. Both laser techniques and cone-beam computed tomography of the phantoms were used for comparison. Results: The printed material exhibited mechanical parameters similar to those of blood vessel walls. The refractive index of 1.473 ± 0.002 and high transparency allowed for non-invasive laser examination of the interior of the print. The printed models behaved similarly to human arteries in vivo, allowing training in treatment procedures and considering vessel deformation during the procedure. Models with stents can be analyzed using laser and cone-beam computed tomography to compare stents from different manufacturers. Conclusions: The developed methodology allows for simple and time-efficient production of personalized vessel phantoms.
Introduction: This study was designed to assess quantitatively a safe position of the microcatheter during the SIRT (Selective Internal Radiation Therapy) procedure, in order to minimize the risk of non-target spheres leaking. Materials and Methods: Retrospective analysis of the distance of the tip of the microcatheter from coiled or patent non-target arteries was measured during 99mTc-MAA work-up procedure. Frequency of extrahepatic leaking during work-up and SIRT procedures was evaluated. Results: There were 85 patients who underwent 98 work-up procedures. There were 64 radioembolizations. There were 44 gastroduodenal, 51 right gastric, and 54 cystic artery embolizations performed. Extrahepatic 99mTc-MAA leaking was observed in 33 cases: 16 to gallbladder, four to a gastric wall, nine to the duodenum, one to the intestinal wall, and three to the abdominal wall. Leak in 99mTc-MAA was also related to the presence of additional arteries (p = 0.009). There were 34 proximal and 31 distal to cystic artery 99mTc-MAA injections resulting in 12 vs. four leaks, respectively (p = 0.039, RR-2.5). Mean distance of the tip of the microcatheter from the origin of the cystic artery was 20 mm (minimum of 2.1 mm and maximum of 53 mm) proximally and 10 mm (minimum 1 mm and maximum 51 mm) distally (ns). Conclusions: Leaking in 99mTc-MAA (99mTc - labelled macroaggregated albumin) was related to the presence of additional arteries. Regardless of cystic artery embolization, it is 2.5 times safer to inject microspheres distal to its origin, compared to proximal injection. Cystic artery origin relative to the right hepatic artery division usually necessitates embolization of the former.
Background and Objectives: Hypertension increases the risk of developing atherosclerosis and arterial stiffness, with secondarily enhanced wall stress pressure that damages the artery wall. The coexistence of atherosclerosis and hypertension leads to artery stenosis and microvascular angiopathies, during which the intravascular mechanical hemolysis of red blood cells (RBCs) occurs, leading to increased platelet activation, dysfunction of the endothelium and smooth muscle cells due to a decrease in nitric oxide, and the direct harmful effects of hemoglobin and iron released from the red blood cells. This study analyzed the impact of hypertension and physical exercise on the risk of hemolysis in the left coronary artery. Methods: To analyze many different cases and consider the decrease in flow through narrowed arteries, a flow model was adopted that considered hydraulic resistance in the distal section, which depended on the conditions of hypertension and exercise. The commercial ANSYS Fluent 2023R2 software supplemented with user-defined functions was used for the simulation. CFD simulations were performed and compared with the FSI simulation results. Results: The differences obtained between the FSI and CFD simulations were negligible, which allowed the continuation of analyses based only on CFD simulations. The drops in pressure and the risk of hemolysis increased dramatically with increased flow associated with increased exercise. A relationship was observed between the increase in blood pressure and hypertension, but in this case, the increase in blood pressure dropped, and the risk of hemolysis was not so substantial. However, by far, the case of increased physical activity with hypertension had the highest risk of hemolysis, which is associated with an increased risk of clot formation that can block distal arteries and lead to myocardial hypoxia. Conclusions: The influence of hypertension and increased physical exercise on the increased risk of hemolysis has been demonstrated.
Background: The inadvertent detachment of stent retrievers during mechanical thrombectomy is an extremely rare but feared complication associated with poor clinical outcomes. We discuss management considerations after an unexpected disconnection of the pRESET stent retriever during mechanical thrombectomy, based on clinical experience and mechanical and phantom studies. Methods: We present a clinical course of rare accidents of stent-retriever separation inside an intracranial vessel that occurred in patients in a comprehensive stroke centre between 2018 and 2020. We designed a phantom study to assess the Tigertriever’s ability to remove a detached stent retriever from intercranial vessels. In the mechanical study, several types of stent retrievers were evaluated in order to find the weakest point at which detachment occurred. Results: Two patients (~0.7%) with inadvertent stent-retriever detachment were found in our database. Failed attempts of endovascular removal with no recanalization at the end of procedure were reported in both cases. mRS after 3 months was three and four respectively. In the mechanical study, the Tigertriever was the most resistant to detachment and was followed by Embotrap > pRESET > 3D Separator. In the phantom study, the pRESET device detached in a configuration resembling the M1 segment was successfully removed with the Tigertriever. Conclusions: Conservative management of the inadvertent detachment of stent retrievers during mechanical thrombectomy in large vessel occlusion may be acceptable in order to avoid further periprocedural complications after unsuccessful device removal attempts. Based on the phantom and mechanical studies, the Tigertriever may be a useful tool for the removal of detached pRESET devices.