Piotr Piasecki

Dr. Piotr Piasecki

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PPPiotr Piasecki
Piotr Piasecki
Jerzy NarlochJerzy Narloch
Jerzy Narloch
KBKrzysztof Brzozowski
Krzysztof Brzozowski
PZPiotr Zięcina
Piotr Zięcina
AMAndrzej Mazurek
Andrzej Mazurek
MDMirosław Dziuk
Mirosław Dziuk
The aim of this study was to evaluate a modified method of calculating the 99mTc/90Y tumor-to-normal-liver uptake ratio (mT/N) based on SPECT/CT imaging, for use in predicting the overall response of colorectal liver tumors after radioembolization. A modified phantom-based method of tumor-to-normal-liver ratio calculation was proposed and assessed. In contrast to the traditional method based on data gathered from the whole tumor, gamma counts are collected only from a 2D region of interest delineated in the SPECT/CT section with the longest tumor diameter (as specified in RECIST 1.1). The modified tumor-to-normal-liver ratio (mT/N1) and 90Y predicted tumor absorbed dose (PAD) were obtained based on 99mTc-MAA SPECT/CT, and similarly the modified tumor-to-normal-liver ratio (mT/N2) and 90Y actual tumor absorbed dose (AAD) were calculated after 90Y-SPECT/CT. Tumor response was assessed on follow-up CTs. Using the newly proposed method, a total of 103 liver colorectal metastases in 21 patients who underwent radioembolization (between June 2009 and October 2015) were evaluated in pre-treatment CT scans and 99mTc-MAA-SPECT/CT scans and compared with post-treatment 90Y-SPECT/CT scans and follow-up CT scans. The results showed that the mT/N1 ratio (p = 0.012), PAD (p < 0.001) and AAD (p < 0.001) were predictors of tumor response after radioembolization. The time to progression was significantly lengthened for tumors with mT/N1 higher than 1.7 or PAD higher than 70 Gy. The risk of progression for tumors with mT/N1 lower than 1.7 or PAD below 70 Gy was significantly higher. The mT/N2 ratio had no significant correlation with treatment results. The mT/N1 ratio, PAD, and AAD can be used as predictors of tumor response to SIRT treatment, and SPECT/CT imaging can be used for dosimetric assessment of radioembolization.

1 September 2017 in Neurologia i Neurochirurgia Polska
Verified
Journal Article
Closed access
ASAgnieszka Słowik
Agnieszka Słowik
MWMarcin Wnuk
Marcin Wnuk
PBPaweł Brzegowy
Paweł Brzegowy
JCJoanna Chrzanowska-Waśko
Joanna Chrzanowska-Waśko
AGAleksandra Golenia
Aleksandra Golenia
TPTadeusz J. Popiela
Tadeusz J. Popiela
Mechanical thrombectomy (MT) is not reimbursed by the Polish public health system. We present a description of 5 years of experience with MT in acute stroke in Comprehensive Stroke Centers (CSCs) in Poland. We retrospectively analyzed the results of a structured questionnaire from 23 out of 25 identified CSCs and 22 data sets that include 61 clinical, radiological and outcome measures. Most of the CSCs (74%) were founded at University Hospitals and most (65.2%) work round the clock. In 78.3% of them, the working teams are composed of neurologists and neuro-radiologists. All CSCs perform CT and angio-CT before MT. In total 586 patients were subjected to MT and data from 531 of them were analyzed. Mean time laps from stroke onset to groin puncture was 250±99min. 90.3% of the studied patients had MT within 6h from stroke onset; 59.3% of them were treated with IV rt-PA prior to MT; 15.1% had IA rt-PA during MT and 4.7% - emergent stenting of a large vessel. M1 of MCA was occluded in 47.8% of cases. The Solitaire device was used in 53% of cases. Successful recanalization (TICI2b-TICI3) was achieved in 64.6% of cases and 53.4% of patients did not experience hemorrhagic transformation. Clinical improvement on discharge was noticed in 53.7% of cases, futile recanalization - in 30.7%, mRS of 0-2 - in 31.4% and mRS of 6 in 22% of cases. Our results can help harmonize standards for MT in Poland according to international guidelines.

22 December 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
KJKrystian Jędrzejczak
Krystian Jędrzejczak
WOWojciech Orciuch
Wojciech Orciuch
KWKrzysztof Wojtas
Krzysztof Wojtas
MKMichal Kozlowski
Michal Kozlowski
PPPiotr Piasecki
Piotr Piasecki
ŁMŁukasz Makowski
Łukasz Makowski
Atherosclerosis affects human health in many ways, leading to disability or premature death due to ischemic heart disease, stroke, or limb ischemia. Poststenotic blood flow disruption may also play an essential role in artery wall impairment linked with hemolysis related to shear stress. The maximum shear stress in the atherosclerotic plaque area is the main parameter determining hemolysis risk. In our work, a 3D internal carotid artery model was built from CT scans performed on patients qualified for percutaneous angioplasty due to its symptomatic stenosis. The obtained stenosis geometries were used to conduct a series of computer simulations to identify critical parameters corresponding to the increase in shear stress in the arteries. Stenosis shape parameters responsible for the increase in shear stress were determined. The effect of changes in the carotid artery size, length, and degree of narrowing on the change in maximum shear stress was demonstrated. Then, a correlation for the quick initial diagnosis of atherosclerotic stenoses regarding the risk of hemolysis was developed. The developed relationship for rapid hemolysis risk assessment uses information from typical non-invasive tests for treated patients. Practical guidelines have been developed regarding which stenosis shape parameters pose a risk of hemolysis, which may be adapted in medical practice.

16 October 2017 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
PPPiotr Piasecki
Piotr Piasecki
TZTomasz Zabkowski
Tomasz Zabkowski
KBK. Brzozowski
K. Brzozowski
JNJ. Narloch
J. Narloch
PZP. Zięcina
P. Zięcina
HZH. Zieliński
H. Zieliński

14 September 2022 in Radiation Physics and Chemistry
Verified
Journal Article
Open access
MMMaciej Maciak
Maciej Maciak
MKMarcin Konior
Marcin Konior
DWDanuta Wawszczak
Danuta Wawszczak
AMAleksandra Majewska
Aleksandra Majewska
KBKlaudia K. Brodaczewska
Klaudia K. Brodaczewska
EIEdward Iller
Edward Iller

28 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KJKrystian Jędrzejczak
Krystian Jędrzejczak
AAArkadiusz Antonowicz
Arkadiusz Antonowicz
Beata Butruk-RaszejaBeata Butruk-Raszeja
Beata Butruk-Raszeja
WOWojciech Orciuch
Wojciech Orciuch
KWKrzysztof Wojtas
Krzysztof Wojtas
ŁMŁukasz Makowski
Łukasz Makowski
Background/Objective: Atherosclerosis is becoming increasingly common in modern society. Owing to the increasing number of complex angioplasty procedures, there is an increasing need for training in cases where the risk of periprocedural complications is high. Methods: A procedure was developed to obtain three-dimensional (3D) models and printing of blood vessels. The mechanical and optical properties of the printed materials were also examined. Angioplasty and stent implantation were tested, and the phantom was compared with the clinical data of patients who underwent interventional treatment. Both laser techniques and cone-beam computed tomography of the phantoms were used for comparison. Results: The printed material exhibited mechanical parameters similar to those of blood vessel walls. The refractive index of 1.473 ± 0.002 and high transparency allowed for non-invasive laser examination of the interior of the print. The printed models behaved similarly to human arteries in vivo, allowing training in treatment procedures and considering vessel deformation during the procedure. Models with stents can be analyzed using laser and cone-beam computed tomography to compare stents from different manufacturers. Conclusions: The developed methodology allows for simple and time-efficient production of personalized vessel phantoms.