Aleš Zore

Mr. Aleš Zore

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in IEEE Sensors Journal
Verified
Journal Article
Open access
EBEmmanuel Bacher
Emmanuel Bacher
SESergio Cartiel Embid
Sergio Cartiel Embid
JGJorge Garcia-Pueyo
Jorge Garcia-Pueyo
JSJulija Stopar
Julija Stopar
AZAleš Zore
Aleš Zore
MLMartin Laurenzis
Martin Laurenzis
Light Detection and Ranging (LIDAR) sensors, employing direct Time-of-Flight (dTOF) measurements, are crucial for precise surface localization and are increasingly integrated into compact chip designs. These sensors have extensive use in proximity sensing in various applications. This paper presents the innovative use of LIDAR sensors for ranging within wave guides to accurately detect touch and pressure. In our OptoSkin sensors, light propagates via total internal reflection (TIR) within the wave guide. Then it is reflected back to the sensor as a result of wave guide deformation and/or scattering in the contact area, a phenomenon attributed to frustrated total internal reflection (FTIR). We have designed, simulated, and implemented different OptoSkin sensors using wave guides constructed from a flexible rod, rigid curved 3D printed resin, and planar soft silicone rubber, respectively. Each configuration is equipped with multiple LIDAR sensors, demonstrating effective localization of touch points. In addition, pressure sensing was performed on the elastic wave guides. These novel touch sensors show great potential for applications such as robotic sensor skins, which enhance tactile responsiveness and interaction.

11 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
IAIlze Aulika
Ilze Aulika
AOAndrejs Ogurcovs
Andrejs Ogurcovs
MKMeldra Kemere
Meldra Kemere
ABArturs Bundulis
Arturs Bundulis
JBJelena Butikova
Jelena Butikova
RKRoman Kamnik
Roman Kamnik
Optical tactile sensing is gaining traction as a foundational technology in collaborative and human-interactive robotics, where reliable touch and pressure feedback are critical. Traditional systems based on total internal reflection (TIR) and frustrated TIR (FTIR) often require complex infrared setups and lack adaptability to curved or flexible surfaces. To overcome these limitations, we developed OptoSkin—a novel tactile platform leveraging direct time-of-flight (ToF) LiDAR principles for robust contact and pressure detection. In this extended study, we systematically evaluate how key optical properties of waveguide materials affect ToF signal behavior and sensing fidelity. We examine a diverse set of materials, characterized by varying light transmission (82–92)%, scattering coefficients (0.02–1.1) cm−1, diffuse reflectance (0.17–7.40)%, and refractive indices 1.398–1.537 at the ToF emitter wavelength of 940 nm. Through systematic evaluation, we demonstrate that controlled light scattering within the material significantly enhances ToF signal quality for both direct touch and near-proximity sensing. These findings underscore the critical role of material selection in designing efficient, low-cost, and geometry-independent optical tactile systems.

11 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AZAleš Zore
Aleš Zore
RČRobert Čerin
Robert Čerin
MMMarko Munih
Marko Munih
In our study a robot was used to deliver objects for measurement into the Equator gauging system. To investigate the robot’s manipulation influence on dimensional measurements, the robot’s tasks were divided into basic functions. Based on these basic functions, nine different robot-manipulation scenarios were defined, i.e., from zero to full robot manipulation, for two measuring objects (named Magnet and PKR) and six measurement characteristics (rectangular and spherical). The robot’s manipulation influence was determined on the basis of the statistical parameters Cp, R, and the 6σ obtained from a measurement system analysis (MSA) type-1 study. The results show that the degree of implemented manipulation of the robot affects the scattering of the measurement data. However, the effect is much more pronounced in the case of length measurements than with spherical geometries. Different measuring methods (touch-triggering or scanning measurement mode, number of sampling points) were used, which showed similar measurement data. This directly indicated the influence of the robot’s manipulation on Cp, R and 6σ. Increasing the degree of the robot’s manipulation decreases the Cp value and increases the R and 6σ values for the length measurements. There is no such pronounced course in the spherical geometries, where the values of Cp, R and 6σ remain approximately the same. The main influential factor for decreasing the Cp value with increasing robot manipulation was the angular misalignment of the object’s orientation in the fixture.

17 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
IAIlze Aulika
Ilze Aulika
AOAndrejs Ogurcovs
Andrejs Ogurcovs
MKMeldra Kemere
Meldra Kemere
ABArturs Bundulis
Arturs Bundulis
JBJelena Butikova
Jelena Butikova
RKRoman Kamnik
Roman Kamnik
Optical tactile sensing is gaining traction as a foundational technology in collaborative and human-interactive robotics, where reliable touch and pressure feedback are critical. Traditional systems based on total internal reflection (TIR) and frustrated TIR (FTIR) often require complex infrared setups and lack adaptability to curved or flexible surfaces. To overcome these limitations, we developed OptoSkin - a novel tactile platform leveraging direct Time-of-Flight (ToF) LiDAR principles for robust contact and pressure detection [1]. In this extended study, we systematically evaluate how key optical properties of waveguide materials affect ToF signal behavior and sensing fidelity. We examine a diverse set of materials, characterized by varying light transmission (82 - 92)* %, scattering coefficients (0.02 - 1.1 ) cm⁻¹, diffuse reflectance (0.17 - 7.40) %, and refractive indices 1.398 - 1.537. Through systematic evaluation, we demonstrate that controlled light scattering within the material significantly enhances ToF signal quality for both direct touch and near-proximity sensing. These findings underscore the critical role of material selection in designing efficient, low-cost, and geometry-independent optical tactile systems.

1 September 2026 in IEEE Sensors Journal
Verified
Journal Article
Open access
AZAleš Zore
Aleš Zore
MBMarina Babic
Marina Babic
MMMarko Munih
Marko Munih
RKRoman Kamnik
Roman Kamnik

26 April 2026 in Technologies
Verified
Journal Article
Open access
PDF file
AZAleš Zore
Aleš Zore
MMMarko Munih
Marko Munih
The influence of a robot’s manipulation can be observed in a robotic measurement system. Different robot end-effector trajectories yield different robot end-effector accuracy and repeatability errors. Trajectory parameters, robot motion type, velocity, and length of motion were identified as influential sources. A robot arm was used to insert measuring objects into the measurement device for dimensional measurements. In the first part, the measurement datasets for linear and joint robot motions were compared for three different velocities and four motion lengths. The influence of the number of active joints in the robot’s motion was compared for two velocities and four magnitudes of joint rotation. Dimensional measurement variability was analysed using measurement system analysis (MSA), and the statistical influence of trajectory parameters was further addressed by analysis of variance (ANOVA). All identified trajectory parameters have a statistically significant impact on measurement variability, reflecting the robot end-effector’s accuracy and repeatability errors. Linear motion provides higher measurement variability up to 20%, a velocity increase that is typically up to 25–35% and motion length that is typically up to 15–35%.