Elisa Rupérez

Dr. Elisa Rupérez

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2015 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Open access
PDF file
Carles Mas MorunoCarles Mas Moruno
Carles Mas Moruno
BGBeatriz Garrido
Beatriz Garrido
DRDaniel Rodriguez
Daniel Rodriguez
ERElisa Rupérez
Elisa Rupérez
FGF. Javier Gil
F. Javier Gil
The use of tantalum as biomaterial for orthopedic applications is gaining considerable attention in the clinical practice because it presents an excellent chemical stability, body fluid resistance, biocompatibility, and it is more osteoconductive than titanium or cobalt-chromium alloys. Nonetheless, metallic biomaterials are commonly bioinert and may not provide fast and long-lasting interactions with surrounding tissues. The use of short cell adhesive peptides derived from the extracellular matrix has shown to improve cell adhesion and accelerate the implant’s biointegration in vivo. However, this strategy has been rarely applied to tantalum materials. In this work, we have studied two immobilization strategies (physical adsorption and covalent binding via silanization) to functionalize tantalum surfaces with a cell adhesive RGD peptide. Surfaces were used untreated or activated with either HNO3 or UV/ozone treatments. The process of biofunctionalization was characterized by means of physicochemical and biological methods. Physisorption of the RGD peptide on control and HNO3-treated tantalum surfaces significantly enhanced the attachment and spreading of osteoblast-like cells; however, no effect on cell adhesion was observed in ozone-treated samples. This effect was attributed to the inefficient binding of the peptide on these highly hydrophilic surfaces, as evidenced by contact angle measurements and X-ray photoelectron spectroscopy. In contrast, activation of tantalum with UV/ozone proved to be the most efficient method to support silanization and subsequent peptide attachment, displaying the highest values of cell adhesion. This study demonstrates that both physical adsorption and silanization are feasible methods to immobilize peptides onto tantalum-based materials, providing them with superior bioactivity.

1 May 2017 in European Polymer Journal
Verified
Journal Article
Closed access
ARAlejandra Rodríguez-Contreras
Alejandra Rodríguez-Contreras
YGYolanda García
Yolanda García
JMJosé María Manero
José María Manero
ERElisa Rupérez
Elisa Rupérez

27 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
Javier GilJavier Gil
Javier Gil
Jose Maria ManeroJose Maria Manero
Jose Maria Manero
ERElisa Rupérez
Elisa Rupérez
Eugenio Velasco-OrtegaEugenio Velasco-Ortega
Eugenio Velasco-Ortega
ÁJÁlvaro Jiménez-Guerra
Álvaro Jiménez-Guerra
LMLoreto Monsalve-Guil
Loreto Monsalve-Guil
The surface modification by the formation of apatitic compounds, such as hydroxyapatite, improves biological fixation implants at an early stage after implantation. The structure, which is identical to mineral content of human bone, has the potential to be osteoinductive and/or osteoconductive materials. These calcium phosphates provoke the action of the cell signals that interact with the surface after implantation in order to quickly regenerate bone in contact with dental implants with mineral coating. A new generation of calcium phosphate coatings applied on the titanium surfaces of dental implants using laser, plasma-sprayed, laser-ablation, or electrochemical deposition processes produces that response. However, these modifications produce failures and bad responses in long-term behavior. Calcium phosphates films result in heterogeneous degradation due to the lack of crystallinity of the phosphates with a fast dissolution; conversely, the film presents cracks, which produce fractures in the coating. New thermochemical treatments have been developed to obtain biomimetic surfaces with calcium phosphate compounds that overcome the aforementioned problems. Among them, the chemical modification using biomineralization treatments has been extended to other materials, including composites, bioceramics, biopolymers, peptides, organic molecules, and other metallic materials, showing the potential for growing a calcium phosphate layer under biomimetic conditions.

1 October 2015 in Materials & Design
Verified
Journal Article
Open access
ERElisa Rupérez
Elisa Rupérez
JMJ.M. Manero
J.M. Manero
KRK. Riccardi
K. Riccardi
YLYuping Li
Yuping Li
Conrado AparicioConrado Aparicio
Conrado Aparicio
FGF.J. Gil
F.J. Gil
In the present study, production of tantalum porous scaffolds using the space holder technique was performed. The effect of size and content of sodium chloride particles, used as space holder, as well as compacting pressure on foam structure and mechanical properties have been investigated. The morphological characterization was carried out by means of scanning electron microscopy (SEM), mercury intrusion porosimetry (MIP) and micro-CT technique. The relationship between the elastic modulus and yield strength of the tantalum porous scaffold and the pore structure was evaluated. Space holder technique allows obtaining tantalum open-cell structure (70% of porosity) and modulus of elasticity similar to cancellous bone, with reproducible processability into three-dimensional structures and reasonable manufacturing costs.Peer ReviewedPostprint (author’s final draft

26 February 2013 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
MAM. V. Alfonso
M. V. Alfonso
EEEduardo Espinar
Eduardo Espinar
JLJ. M. Llamas
J. M. Llamas
ERElisa Rupérez
Elisa Rupérez
Jose Maria ManeroJose Maria Manero
Jose Maria Manero
Javier GilJavier Gil
Javier Gil

14 June 2020 in Metals
Verified
Journal Article
Open access
PDF file
RPRoberto Padrós
Roberto Padrós
MFMiquel Punset Fuste
Miquel Punset Fuste
MMMeritxell Molmeneu Molmeneu
Meritxell Molmeneu Molmeneu
Aritza Brizuela-VelascoAritza Brizuela-Velasco
Aritza Brizuela-Velasco
Mariano Herrero-ClimentMariano Herrero-Climent
Mariano Herrero-Climent
Javier GilJavier Gil
Javier Gil
The aim of this study is to compare the mechanical properties of three different dental restorations’ manufacturing processes (CADCAM milling, casting and laser sintering) generated by only one laboratory scanner focusing on marginal fit analysis and their mechanical properties. A chrome-cobalt (Cr-Co) alloy from the same batch was used for three different methods to make an implant abutment. This simulates a maxillary right first molar that was fixed in a hemi-maxillary stone model. Five scans were performed by each tested framework. Nine frameworks were manufactured for each manufacture procedure. Field-Emission Scanning Electron Microscope (FE-SEM) direct vision was used to marginal gap measurement in five critical points for each specimen. In order to fix the samples in the microscope chamber, the restorations were submitted at a compression load of 50 N. The samples always have the same orientation and conditions. The resolution of the microscope is 4 nm and it is equipped by J image software. The microstructure of the samples was also determined with the FE-SEM equipped with EDS-microanalysis. Roughness parameters were measured using White Light Interferometry (WLI). The arithmetical mean for the Ra and Rq of each sample was calculated. The samples were mechanically characterized by means of microhardness and flexural testing. Servo-hydraulic testing machine was used with cross-head rate of 1 mm/min. Two-way ANOVA statistical analysis was performed to determine whether the marginal discrepancies and mechanical properties were significantly different between each group (significance level p < 0.05). The overall mean marginal gap values were: from 50.53 ± 10.30 µm for the samples produced by CADCAM to 85.76 ± 22.56 µm for the samples produced by the casting method. Laser sintering presents a marginal gap of 60.95 ± 20.66 µm. The results revealed a statistically significant difference (p-value < 0.005) in the mean marginal gap between the CADCAM systems studied. The higher flexure load to fracture for these restorations were for CADCAM restoration and the lower was for the casting samples. For these restorations, CADCAM Restoration yielded a higher flexure load to fracture and Casting ones yielded the lower. Porosity and microstructure play a very important role in the mechanical properties.