Tobias Krille

Mr. Tobias Krille


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2022 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Open access
TKTobias Krille
Tobias Krille
RPRico Poser
Rico Poser
JWJens von Wolfersdorf
Jens von Wolfersdorf
MHMarc Henze
Marc Henze

29 March 2022 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
TKTobias Krille
Tobias Krille
RPRico Poser
Rico Poser
MDMarkus Diel
Markus Diel
JWJens von Wolfersdorf
Jens von Wolfersdorf
Thermocouples are often used for temperature measurements. Under transient conditions, measurement errors can occur due to capacitive inertia and heat conduction along the stem of the thermocouples. To correct such errors, a method is presented in Part I [1] of this paper, which uses a simplified analytical approach and a numerical solution. In the present work, this method is applied to temperature measurements. Several experiments with different thermocouple designs were performed to investigate different conditions such as installation depth, thermocouple type and transient temperature rises. In all cases, two thermocouples were placed so that they are exposed to the same fluid temperature. They are installed with short or long immersion length, respectively. It is shown that only the short thermocouple experiences a thermal conduction error, but both are subject to thermal inertia. The importance of compensating for these effects is shown by quantifying the errors in a typical heat transfer experiment when they are neglected. It is shown, which parameters are necessary for a re-calculation of fluid temperatures when two thermocouples are present at the same measuring position. Furthermore, a simplified method is described, which can be applied if the instrumentation of only one thermocouple is possible.

1 April 2022 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Open access
TKTobias Krille
Tobias Krille
RPRico Poser
Rico Poser
JWJens von Wolfersdorf
Jens von Wolfersdorf
MHMarc Henze
Marc Henze

26 April 2021 in Journal of Turbomachinery
Verified
Journal Article
Open access
PDF file
TKTobias Krille
Tobias Krille
SRStefan Retzko
Stefan Retzko
RPRico Poser
Rico Poser
JWJens Von Wolfersdorf
Jens Von Wolfersdorf
The transient thermochromic liquid crystal (TLC) method is applied to determine the distribution of the local heat transfer coefficients using a configuration with parallel cooling channels at an engine-relevant Reynolds number. The rectangular channels with a moderate aspect ratio and a high length-to-diameter ratio are equipped with one-sided oblique ribs with high blockage, which is a promising configuration for turbine near-wall cooling applications. In this arrangement, the three inner channels should experience same flow and thermal conditions. Numerical simulations are performed to substantiate this assumption. The symmetric single channels are sprayed with narrowband TLC with various indication temperatures. Multiple experiments were conducted. All start at ambient conditions before the fluid is heated up to several temperatures between 46 °C and 73 °C. The results show that the determined local heat transfer coefficients and therefore the Nusselt numbers vary significantly for the different experimental conditions especially at locations of high heat transfer coefficient behind the ribs. A simplified procedure with respect to measurement uncertainties is applied to enable an easy and fast valuation of the data quality. This might be used within the data reduction analysis for such experiments directly. The approach is illustrated using the obtained experimental data.


16 July 2021
Verified
Preprint
Open access
TKTobias Krille
Tobias Krille
SRStefan Retzko
Stefan Retzko
RPRico Poser
Rico Poser
JWJens Von Wolfersdorf
Jens Von Wolfersdorf
Division / Sponsor: International Gas Turbine Institute (IGTI)