Vasileios Sousonis

Dr. Vasileios Sousonis

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
LMLorenzo Marcon
Lorenzo Marcon
MMMichele Magnocavallo
Michele Magnocavallo
Roberto MenèRoberto Menè
Roberto Menè
LPLuigi Pannone
Luigi Pannone
MMMark La Meir
Mark La Meir
Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan–Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.

1 January 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
Roberto MenèRoberto Menè
Roberto Menè
SBSerge Boveda
Serge Boveda
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
VSVasileios Sousonis
Vasileios Sousonis
GVGiampaolo Vetta
Giampaolo Vetta
SCStéphane Combes
Stéphane Combes

1 December 2016 in International Journal of Cardiology
Verified
Journal Article
Closed access
MTMichalis Tsamatsoulis
Michalis Tsamatsoulis
Chris KapeliosChris Kapelios
Chris Kapelios
LKLambros Katsaros
Lambros Katsaros
SVStella Vakrou
Stella Vakrou
VSVasileios Sousonis
Vasileios Sousonis
KMKonstantinos Malliaras
Konstantinos Malliaras

12 July 2024 in Current Cardiology Reports
Verified
Journal Article
Closed access
PDF file
VSVasileios Sousonis
Vasileios Sousonis
DADimitrios Asvestas
Dimitrios Asvestas
EVEmmanouil Vavouris
Emmanouil Vavouris
SKStavros Karanikas
Stavros Karanikas
EYElissavet Ypsilanti
Elissavet Ypsilanti
STStylianos Tzeis
Stylianos Tzeis

17 March 2022 in Clinical Cardiology
Verified
Journal Article
Open access
DADimitrios Asvestas
Dimitrios Asvestas
VSVasileios Sousonis
Vasileios Sousonis
GKGeorge Kotsovolis
George Kotsovolis
SKStavros Karanikas
Stavros Karanikas
AXAnastasia Xintarakou
Anastasia Xintarakou
STStylianos Tzeis
Stylianos Tzeis
Background: Force‐time integral (FTI) is an ablation marker of lesion quality and transmurality. A target FTI of 400 gram‐seconds (gs) has been shown to improve durability of pulmonary vein isolation, following atrial fibrillation ablation. However, relevant targets for cavotricuspid isthmus (CTI) ablation are lacking.Hypothesis: We sought to investigate whether CTI ablation with 600 gs FTI lesions is associated with reduced rate of transisthmus conduction recovery compared to 400 gs lesions.Methods: Fifty patients with CTI‐dependent flutter were randomized to ablation using 400 gs (FTI400 group, n = 26) or 600 gs FTI lesions (FTI600 group, n = 24). The study endpoint was spontaneous or adenosine‐mediated recovery of transisthmus conduction, after a 20‐min waiting period.Results: The study endpoint occurred in five patients (19.2%) in group FTI400 and in four patients (16.7%) in group FTI600, p = .81. First‐pass CTI block was similar in both groups (50% in FTI400 vs. 54.2% in FTI600, p = .77). There were no differences in the total number of lesions, total ablation time, procedure time and fluoroscopy duration between the two groups. There were no major complications in any group. In the total population, patients not achieving first‐pass CTI block had significantly higher rate of acute CTI conduction recovery, compared to those with first‐pass block (29.2% vs. 7.7% respectively, p = .048).Conclusions: CTI ablation using 600 gs FTI lesions is not associated with reduced spontaneous or adenosine‐mediated recurrence of transisthmus conduction, compared to 400 gs lesions.

1 February 2024 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
PDF file
VSVasileios Sousonis
Vasileios Sousonis
QVQuentin Voglimacci-Stephanopoli
Quentin Voglimacci-Stephanopoli
SZSarah Zeriouh
Sarah Zeriouh
SBSerge Boveda
Serge Boveda
JAJean Paul Albenque
Jean Paul Albenque
Background: Ablation of persistent atrial fibrillation (AF) remains challenging, with atrial substrate modification often being performed as an adjunct to pulmonary vein isolation (PVI). Pulsed field ablation (PFA) is a novel ablation modality that carries a favourable safety profile, which could facilitate complex procedures. Case summary: We present the case of a 60-year-old male undergoing catheter ablation for symptomatic persistent AF. The procedure was performed with the Farapulse™ PFA system in a stepwise manner, including PVI and linear lesions for the isolation of the posterior left atrial wall and the ablation of the mitral isthmus. The final step of the procedure included the ablation of areas exhibiting spatiotemporal electrogram dispersion, identified with the help of artificial intelligence–based software (VX1, Volta Medical) in both atria. Sinus rhythm was restored after the abolition of an electrogram dispersion zone in the right atrium. The procedure was carried out without any complications. Discussion: Complex ablation procedures for persistent AF can be successfully performed with PFA. In the context of such extensive ablation strategies, PFA is an attractive energy source, given its non-thermal nature that is known to prevent damage to surrounding tissue and result in less chronic fibrosis. However, caution should be exercised to avoid excessive ablation when using the currently available multispline PFA catheter, as it may inadvertently target adjacent areas of healthy myocardium.