Michele Magnocavallo

Dr. Michele Magnocavallo

Università La Sapienza, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
LMLorenzo Marcon
Lorenzo Marcon
MMMichele Magnocavallo
Michele Magnocavallo
Roberto MenèRoberto Menè
Roberto Menè
LPLuigi Pannone
Luigi Pannone
MMMark La Meir
Mark La Meir
Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan–Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.

12 October 2020 in Journal of Thrombosis and Thrombolysis
Verified
Journal Article
Open access
PDF file
MMMarco Valerio Mariani
Marco Valerio Mariani
MMMichele Magnocavallo
Michele Magnocavallo
MSMartina Straito
Martina Straito
APAgostino Piro
Agostino Piro
SPSeverino Paolo
Severino Paolo
CLCarlo Lavalle
Carlo Lavalle
Background: Direct oral anticoagulants (DOACs) are recommended as first-line anticoagulants in patients with atrial fibrillation (AF). However, in patients with cancer and AF the efficacy and safety of DOACs are not well established. Objective: We performed a meta-analysis comparing available data regarding the efficacy and safety of DOACs vs vitamin K antagonists (VKAs) in cancer patients with non-valvular AF. Methods: An online search of Pubmed and EMBASE libraries (from inception to May, 1 2020) was performed, in addition to manual screening. Nine studies were considered eligible for the meta-analysis involving 46,424 DOACs users and 182,797 VKA users. Results: The use of DOACs was associated with reduced risks of systemic embolism or any stroke (RR 0.65; 95% CI 0.52–0.81; p 0.001), ischemic stroke (RR 0.84; 95% CI 0.74–0.95; p 0.007) and hemorrhagic stroke (RR 0.61; 95% CI 0.52–0.71; p 0.00001) as compared to VKA group. DOAC use was associated with significantly reduced risks of major bleeding (RR 0.68; 95% CI 0.50–0.92; p 0.01) and intracranial or gastrointestinal bleeding (RR 0.64; 95% CI 0.47–0.88; p 0.006). Compared to VKA, DOACs provided a non-statistically significant risk reduction of the outcomes major bleeding or non-major clinically relevant bleeding (RR 0.94; 95% CI 0.78–1.13; p 0.50) and any bleeding (RR 0.91; 95% CI 0.78–1.06; p 0.24). Conclusions: In comparison to VKA, DOACs were associated with a significant reduction of the rates of thromboembolic events and major bleeding complications in patients with AF and cancer. Further studies are needed to confirm our results.

6 March 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
MBMarco Bergonti
Marco Bergonti
FSFrederic Sacher
Frederic Sacher
Elena ArbeloElena Arbelo
Elena Arbelo
LCLia Crotti
Lia Crotti
ASAvi Sabbag
Avi Sabbag
GCGiulio Conte
Giulio Conte
Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation. In our large cohort of 370 Brugada syndrome (BrS) patients from 18 international centers monitored continuously with an implantable loop recorder (ILR) for 3 years, 25.4% of the patients experienced an arrhythmic event (per-patient analysis). Specifically, 16% experienced an atrial arrhythmia, 5% a ventricular arrhythmia (VA), and 8% a bradyarrhythmia (per-event analysis). The occurrence of arrhythmic syncope in the whole cohort was 8.6% (32/370). The induction of ventricular fibrillation (VF) during an electrophysiological (EP) study emerged as the only predictor of VAs in this cohort. The clinical implications are detailed in the lower right part of the figure (SCD, sudden cardiac death; PM, pacemaker; ICD, implantable cardioverter-defibrillator; Drugs include anti-arrhythmic drugs and anticoagulants; CA, catheter ablation for atrial arrhythmias or VAs).

28 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMichele Magnocavallo
Michele Magnocavallo
Antonio BellasiAntonio Bellasi
Antonio Bellasi
MMMarco Valerio Mariani
Marco Valerio Mariani
MFMaria Fusaro
Maria Fusaro
MRMaura Ravera
Maura Ravera
LLLuca Di Lullo
Luca Di Lullo
Atrial fibrillation (AF) and chronic kidney disease (CKD) are strictly related; several independent risk factors of AF are often frequent in CKD patients. AF prevalence is very common among these patients, ranging between 15% and 20% in advanced stages of CKD. Moreover, the results of several studies showed that AF patients with end stage renal disease (ESRD) have a higher mortality rate than patients with preserved renal function due to an increased incidence of stroke and an unpredicted elevated hemorrhagic risk. Direct oral anticoagulants (DOACs) are currently contraindicated in patients with ESRD and vitamin K antagonists (VKAs), remaining the only drugs allowed, although they show numerous critical issues such as a narrow therapeutic window, increased tissue calcification and an unfavorable risk/benefit ratio with low stroke prevention effect and augmented risk of major bleeding. The purpose of this review is to shed light on the applications of DOAC therapy in CKD patients, especially in ESRD patients.

28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
MMMichele Magnocavallo
Michele Magnocavallo
CGCarola Gianni
Carola Gianni
SMSanghamitra Mohanty
Sanghamitra Mohanty
AAAmin Al-Ahmad
Amin Al-Ahmad
ANAndrea Natale
Andrea Natale
Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson’s: 0.94; P < 0.001; bias: −0.06 (−2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.

Verified
Journal Article
Open access
PDF file
SPSeverino Paolo
Severino Paolo
ADAndrea D'Amato
Andrea D'Amato
SPSilvia Prosperi
Silvia Prosperi
MMMichele Magnocavallo
Michele Magnocavallo
MMMarco Valerio Mariani
Marco Valerio Mariani
FFFrancesco Fedele
Francesco Fedele
Background: IHD is determined by an inadequate coronary blood supply to the myocardium, and endothelial dysfunction may represent one of the main pathophysiological mechanisms involved. Genetic predisposition to endothelial dysfunction has been associated with IHD and its clinical manifestation. However, studies are often confounding and inconclusive for several reasons, such as interethnic differences. Validation of results in larger cohorts and new populations is needed. The aim of this study is to evaluate the associations between the allelic variants of the eNOS rs1799983 single-nucleotide polymorphism, IHD susceptibility and its clinical presentation. Methods: A total of 362 consecutive patients with suspected myocardial ischemia were enrolled. Patients were divided into three groups: G1, coronary artery disease (CAD); G2, coronary microvascular dysfunction (CMD); and G3, a control group with anatomically and functionally normal coronary arteries. Analysis of three allelic variants, GT, GG and TT, of rs1799983 for the NOS3 gene, encoding for eNOS, was performed. Results: rs1799983_GT was significantly more expressed by the ischemic groups (G1 and G2) compared to G3. The TT variant was significantly more expressed by the G1 group, compared to the G2 group. Among ischemic patients, GT was significantly more expressed in patients with acute coronary syndrome (ACS) presentation, compared to other clinical presentations. In the multivariate analysis, the allelic variant GT was found to potentially represent an independent predictor of IHD and ACS presentation. Conclusion: The presence of the SNP rs1799983_GT, encoding for eNOS, is an independent risk factor for IHD and, remarkably, for ACS presentation, independently of cardiovascular risk factors. These results may be useful for the prediction of IHD development, particularly with an acute clinical manifestation. They may allow the early identification of patients at high risk of developing IHD with an ACS, promoting a genetic-based prevention strategy against IHD.