Extreme atrophy of the maxilla still poses challenges for clinicians. Some of the techniques used to address this issue can be complex, risky, expensive, and time consuming, often requiring skilled surgeons. While many commonly used techniques have achieved very high success rates, complications may arise in certain cases. In this context, the premaxillary device (PD) technique offers a simpler approach to reconstruct severely atrophic maxillae, aiming to avoid more complicated and risky surgical procedures. Finite element analysis (FEA) enables the evaluation of different aspects of dental implant biomechanics. Our results demonstrated that using a PD allows for an optimal distribution of stresses on the basal bone, avoiding tension peaks that can lead to bone resorption or implant failure. ANSYS® was used to perform localized finite element analysis (FEA), enabling a more precise examination of the peri-crestal area and the PD through an accurate mesh element reconstruction, which facilitated the mathematical solution of FEA. The most favorable biomechanical behavior was observed for materials such as titanium alloys, which helped to reduce stress levels on bone, implants, screws, and abutments. Additionally, stress values remained within the limits of basal bone and titanium alloy strengths. In conclusion, from a biomechanical point of view, PDs appear to be viable alternatives for rehabilitating severe atrophic maxillae.
This study evaluates the effects of different programs of complex electromagnetic fields (C.M.F.s) on Candida albicans, in planktonic and sessile phase and on human gingival fibroblasts (HGF cells). In vitro cultures of C. albicans ATCC 10231 and HGF cells were exposed to different cycles of C.M.F.s defined as: oxidative stress, oxidative stress/antibacterial, antibacterial, antibacterial/oxidative stress. Colony forming units (CFUs), metabolic activity, cells viability (live/dead), cell morphology, filamentation analysis, and cytotoxicity assay were performed. The broth cultures, exposed to the different C.M.F.s, were grown on titanium discs for 48 h. The quantity comparisons of adhered C. albicans on surfaces were determined by CFUs and scanning electron microscopy. The C. albicans growth could be readily controlled with C.M.F.s reducing the number of cultivable planktonic cells vs. controls, independently by the treatment applied. In particular, the antibacterial program was associated with lower levels of CFUs. The quantification of the metabolic activity was significantly lower by using the oxidative stress program. Live/dead images showed that C.M.F.s significantly decreased the viability of C. albicans. C.M.F.s inhibited C. albicans virulence traits reducing hyphal morphogenesis, adhesion, and biofilm formation on titanium discs. The MTS assay showed no negative effects on the viability of HGF. Independent of the adopted protocol, C.M.F.s exert antifungal and anti-virulence action against C. albicans, no cytotoxicity effects on HGF and can be useful in the prevention and treatment of yeast biofilm infections.
Extreme atrophy of the maxilla poses still challenging for the clinicians. Some of the techniques used could be complex, risky, expensive, time consuming and should be performed, preferably, only by skilled surgeons. Most the commonly used techniques have been reported to have very high success percentages; however, sometimes complications may occur. In this regard, Premaxillary Device (PD) is a technique that has been devised to render more simple the reconstruction of extremely atrophic maxilla, trying to avoid more complicated and risky surgical procedures. Finite Element Analysis (FEA) allows evaluation of several differen aspects of dental implant biomechanics. Our results showed that the use of PD allows an optimal distribution of the stresses on the basal bone, avoiding tension peaks that could determine bone resorption or, even, implant failure. ANSYS has been used to perform this type of localized finite element analysis; with this type of analysis, it was possible to analyze the peri-crestal area of the plant more precisely and the PD through a more accurate reconstruction of the mesh element, which allowed us to mathematically solve the FEA solution. A most favorable biomechanical behavior has been found for the materials such as titanium alloys and reduce stress levels for bone, implants, screws, and abutments. Moreover, the stress values did not exceed bone strength limits for basal bone and titanium alloy. In conclusion, from a biomechanical point of view, PD could be considered a viable alternative for rehabilitation of severe atrophic maxilla.
The purpose of this finite element analysis (FEA) was to evaluate the stress distribution within the prosthetic components and bone in relation to varying cement thicknesses (from 20 to 60 μm) utilized to attach a zirconia crown on a conometric cap. The study focused on two types of implants (Cyroth and TAC, AoN Implants, Grisignano di Zocco, Italy) featuring a Morse cone connection. Detailed three-dimensional (3D) models were developed to represent the bone structure (cortical and trabecular) and the prosthetic components, including the crown, cement, cap, abutment, and the implant. Both implants were placed 1.5 mm subcrestally and subjected to a 200 N load at a 45° inclination on the crown. The results indicated that an increase in cement thickness led to a reduction in von Mises stress on the cortical bone for both Cyroth and TAC implants, while the decrease in stress on the trabecular bone (apical zone) was relatively less pronounced. However, the TAC implant exhibited a higher stress field in the apical area compared to the Cyroth implant. In summary, this study investigated the influence of cement thickness on stress transmission across prosthetic components and peri-implant tissues through FEA analysis, emphasizing that the 60 μm cement layer demonstrated higher stress values approaching the material strength limit.
This study aimed to utilize finite element analysis (FEA) to evaluate the primary stability of Cyroth dental implants (AoN Implants Srl, Grisignano di Zocco, Italy) under various biomechanical conditions, including different implant inclinations (0°, 15°, and 20°) and bone densities (D3 and D4). By comparing these results with those obtained from in vitro tests on polyurethane blocks, the study sought to determine whether FEA could provide stability information more quickly and efficiently than in vitro methods. The research involved correlating dental implant micro-mobility with the implant stability quotient (ISQ) using FEA to simulate the mechanical behavior of implants and the surrounding bone tissue. Additionally, the study assessed the error in ISQ value detection by comparing FEA results with in vitro tests on polyurethane blocks conducted under the same experimental conditions. Both the FEA simulations and in vitro experiments demonstrated similar trends in ISQ values. For the D3 bone block simulated by FEA, the difference from the in vitro test was only 1.27%, while for the D2 bone, the difference was 2.86%. The findings also indicated that ISQ increases with implant inclination and that bone quality significantly affects primary stability, with ISQ decreasing as bone density diminishes. Overall, this study showed that ISQ evaluation for dental implants can be effectively performed through FEA, particularly by examining micro-movements. The results indicated that FEA and in vitro polyurethane testing yielded comparable outcomes, with FEA providing a faster and more cost-effective means of assessing ISQ across various clinical scenarios compared to in vitro testing.