Mario Marioceddia

Dr. Mario Marioceddia

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
ACalessandro cipollina
alessandro cipollina
MMMario Marioceddia
Mario Marioceddia
Natalia Di PietroNatalia Di Pietro
Natalia Di Pietro
Francesco InchingoloFrancesco Inchingolo
Francesco Inchingolo
Margherita TumedeiMargherita Tumedei
Margherita Tumedei
BTBartolomeo Trentadue
Bartolomeo Trentadue
Extreme atrophy of the maxilla still poses challenges for clinicians. Some of the techniques used to address this issue can be complex, risky, expensive, and time consuming, often requiring skilled surgeons. While many commonly used techniques have achieved very high success rates, complications may arise in certain cases. In this context, the premaxillary device (PD) technique offers a simpler approach to reconstruct severely atrophic maxillae, aiming to avoid more complicated and risky surgical procedures. Finite element analysis (FEA) enables the evaluation of different aspects of dental implant biomechanics. Our results demonstrated that using a PD allows for an optimal distribution of stresses on the basal bone, avoiding tension peaks that can lead to bone resorption or implant failure. ANSYS® was used to perform localized finite element analysis (FEA), enabling a more precise examination of the peri-crestal area and the PD through an accurate mesh element reconstruction, which facilitated the mathematical solution of FEA. The most favorable biomechanical behavior was observed for materials such as titanium alloys, which helped to reduce stress levels on bone, implants, screws, and abutments. Additionally, stress values remained within the limits of basal bone and titanium alloy strengths. In conclusion, from a biomechanical point of view, PDs appear to be viable alternatives for rehabilitating severe atrophic maxillae.

16 November 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
LCLuca Comuzzi
Luca Comuzzi
MMMario Marioceddia
Mario Marioceddia
Natalia Di PietroNatalia Di Pietro
Natalia Di Pietro
Francesco InchingoloFrancesco Inchingolo
Francesco Inchingolo
Angelo Michele InchingoloAngelo Michele Inchingolo
Angelo Michele Inchingolo
BTBartolomeo Trentadue
Bartolomeo Trentadue
The issue of dental implant placement relative to the alveolar crest, whether in supracrestal, equicrestal, or subcrestal positions, remains highly controversial, leading to conflicting data in various studies. Three-dimensional (3D) Finite Element Analysis (FEA) can offer insights into the biomechanical aspects of dental implants and the surrounding bone. A 3D model of the jaw was generated using computed tomography (CT) scans, considering a cortical thickness of 1.5 mm. Subsequently, Morse cone implant–abutment connection implants were virtually positioned at the model’s center, at equicrestal (0 mm) and subcrestal levels (−1 mm and −2 mm). The findings indicated the highest stress within the cortical bone around the equicrestally placed implant, the lowest stress in the −2 mm subcrestally placed implant, and intermediate stresses in the −1 mm subcrestally placed implant. In terms of clinical relevance, this study suggested that subcrestal placement of a Morse cone implant–abutment connection (ranging between −1 and −2 mm) could be recommended to reduce peri-implant bone resorption and achieve longer-term implant success.

13 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Natalia Di PietroNatalia Di Pietro
Natalia Di Pietro
MMMario Marioceddia
Mario Marioceddia
Tea RomascoTea Romasco
Tea Romasco
NJNilton De Bortoli Junior
Nilton De Bortoli Junior
BMBruno Freitas Mello
Bruno Freitas Mello
BTBartolomeo Trentadue
Bartolomeo Trentadue
Peri-implant bone resorption has been reported around some implants after loading, which could create problems for the peri-implant soft and hard tissues’ long-term stability. The reasons for this are still not known. However, relevant importance could be given to this due to the presence of a bacterial contamination at the micro-gap level between implant and abutment. In this regard, external and internal implant–abutment assemblies have been shown to be much more permeable to bacterial colonization than Cone-Morse or conical connections. The placement of a subcrestal implant could have aesthetic advantages, therefore allowing a better prosthetic emergence profile. In literature, controversial experimental and clinical results have been reported on bone resorption around implants placed equicrestally and subcrestally. Interestingly, Finite Element Analysis (FEA) studies revealed to be extremely useful for assessing the peri-implant bone strain and stress. Thus, this study conducted a FEA evaluation of implants with a Cone-Morse implant–abutment assembly inserted into a bone block model mimicking equicrestal (0 mm) and subcrestal placements (−1 and −2 mm). Results demonstrated that maximum stresses were observed in the cortical bone around equicrestally placed implants, with the lowest in the 2 mm subcrestally placed implant and intermediate stresses within the 1 mm subcrestally placed implant. The cortical bone resulted more stressed under lateral loads than axial loads. In conclusion, this FEA study suggested a subcrestal implant placement ranging between −1 and −2 mm to obtain an adequate peri-implant stress pattern.

30 January 2024 in Materials
Verified
Journal Article
Open access
PDF file
MMMario Marioceddia
Mario Marioceddia
LLLuciano Lamberti
Luciano Lamberti
BTBartolomeo Trentadue
Bartolomeo Trentadue
The restoration of endodontically treated teeth is one of the main challenges of restorative dentistry. The structure of the tooth is a complex assembly in which the materials that make it up, enamel and dentin, have very different mechanical behaviors. Therefore, finding alternative replacement materials for dental crowns in the area of restorative care isa highly significant challenge, since materials such as ceramic and zirconia have very different stress load resistance values. The aim of this study is to assess which material, either ceramic or zirconia, optimizes the behavior of a restored tooth under various typical clinical conditions and the masticatory load. A finite element analysis (FEA) framework is developed for this purpose. The 3D model of the restored tooth is input into the FEA software (Ansys Workbench R23)and meshed into tetrahedral elements. The presence of masticatory forces is considered: in particular, vertical, 45° inclined, and horizontal resultant forces of 280 N are applied on five contact points of the occlusal surface. The numerical results show that the maximum stress developed in the restored tooth including a ceramic crown and subject to axial load is about 39.381 MPa, which is rather close to the 62.32 MPa stress computed for the natural tooth; stresses of about 18 MPa are localized at the roots of both crown materials. In the case of the zirconia crown, the stresses are much higher than those in the ceramic crown, except for the 45° load direction, while, for the horizontal loads, the stress peak in the zirconia crown is almost three times as large as its counterpart in the ceramic crown (i.e., 163.24 MPa vs. 56.114 MPa, respectively). Therefore, the zirconia crown exhibits higher stresses than enamel and ceramic that could increase in the case of parafunctions, such as bruxism. The clinician’s choice between the two materials should be evaluated based on the patient’s medical condition.

Verified
Journal Article
Open access
PDF file
MMMario Marioceddia
Mario Marioceddia
Giuseppe SolarinoGiuseppe Solarino
Giuseppe Solarino
GGGiorgio Giannini
Giorgio Giannini
GGGiuseppe De Giosa
Giuseppe De Giosa
MTMaria Tucci
Maria Tucci
BTBartolomeo Trentadue
Bartolomeo Trentadue
Total hip arthroplasty is one of the most common and successful orthopaedic operations. Occasionally, periprosthetic osteolysis associated with stress shielding occurs, resulting in a reduction of bone density where the femur is not properly loaded and the formation of denser bone where stresses are confined. To enhance proximal load transfer and reduce stress shielding, approaches, including decreasing the stiffness of femoral stems, such as carbon fibre-reinforced polymer composites (CFRPCs), have been explored through novel modular prostheses. The purpose of the present study was to analyse, by the finite element analysis (FEA) method, the effect that the variation of material for the distal part of the femoral stem has on stress transmission between a modulable prosthesis and the adjacent bone. Methods: Through three-dimensional modelling and the use of commercially available FEA software Ansys R2023, the mechanical behaviour of the distal part of the femoral stem made of CFRPC or Ti-6Al-4V was obtained. A load was applied to the head of the femoral stem that simulates a complete walking cycle. Results: The results showed that the use of a material with mechanical characteristics close to the bone, like CFRPC, allowed for optimisation of the transmitted loads, promoting a better distribution of stress from the proximal to the distal part of the femur. This observation was also found in some clinical studies in literature, which reported not only an improved load transfer with the use of CFRPC but also a higher cell attachment than Ti-6Al-4V. Conclusions: The use of a material that has mechanical properties that are close to bone promotes load transfer from the proximal to the distal area. In particular, the use of CFRPC allows the material to be designed based on the patient’s actual bone characteristics. This provides a customised design with a lower risk of prosthesis loss due to stress shielding.

26 July 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
MMMario Marioceddia
Mario Marioceddia
BTBartolomeo Trentadue
Bartolomeo Trentadue
The natural distribution of stress in the femur is altered when total hip arthroplasty (THA) is performed. In fact, when a stem is inserted inside the femur, there is a variation in stress due to the difference in rigidity between the material with which the stem is made and the femur. This generates the phenomenon of stress shielding. The aim of this study is to design an optimized prosthesis that guarantees an excellent rotational stability and a reduced stress shielding. Methods: Through the finite element method (FEM), the mechanical behavior of the stem subjected to the loads described by ISO 7206-4:2010 is studied. Results: Through topological optimization, there is a reduction in stress shielding in the proximal zone of 31.46%. The addition of ridges on the dorsal side of the stem also improves rotational stability by 27.82%. Conclusions: The decrease in stiffness that is recorded with the optimized stem guarantees a greater distribution of stress on the bone. The presence of dorsal ridges also favors the corticalization of the bone as it loads the bone near the dorsal, ensuring further stability. The perforated prosthesis presented in this study shows an increase in primary stability and an improvement in rotational stability as there is also a bone regrowth inside the prosthesis.