Panteleimon Papamanolis

Dr. Panteleimon Papamanolis

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2020 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
TGThomas Guillod
Thomas Guillod
PPPanteleimon Papamanolis
Panteleimon Papamanolis
JKJohann Kolar
Johann Kolar
This paper analyzes the potential of Artificial Neural Networks (ANNs) for the modeling and optimization of magnetic components and, specifically, inductors. After reviewing the basic properties of ANNs, several potential modeling and design workflows are presented. A hybrid method, which combines the accuracy of 3D Finite Element Method (FEM) and the low computational cost of ANNs, is selected and implemented. All relevant effects are considered (3D magnetic and thermal field patterns, detailed core loss data, winding proximity losses, coupled loss-thermal model, etc.) and the implemented model is extremely versatile (30 input and 40 output variables). The proposed ANN-based model can compute 50'000 designs per second with less than 3% deviation with respect to 3D FEM simulations. Finally, the inductor of a 2kW DC-DC buck converter is optimized with the ANN-based workflow. From the Pareto fronts, a design is selected, measured, and successfully compared with the results obtained with the ANNs. The implementation (source code and data) of the proposed workflow is available under an open-source license.

24 August 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JAJon Azurza
Jon Azurza
GZGrayson Zulauf
Grayson Zulauf
PPPanteleimon Papamanolis
Panteleimon Papamanolis
SHSimon Hobi
Simon Hobi
Spasoje MiricSpasoje Miric
Spasoje Miric
JKJohann Kolar
Johann Kolar
Single-phase inverters and rectifiers, with a DC-side voltage of 400V, achieve ultra-high-efficiency with a simple 2-level topology. These single-phase designs typically utilize a line-frequency unfolder stage, which has very low losses and essentially doubles the peak-to-peak voltage that can be generated on the AC-side for a given DC-link voltage. For three-phase applications, unfolders cannot be similarly used, and the DC-link is typically set to 800V for 230Vrms phase voltage systems. Previous demonstrations indicate that significantly more levels are required for ultra-high-efficiency three-phase converters. We determine the number of levels required for three-phase, 800V DC-link converters to reach the same efficiency as single-phase systems. For this, we derive general scaling laws for bridge-leg losses across number of levels and DC-link voltage, finding the efficiency-optimal chip area and the minimum semiconductor losses. With commercially-available semiconductors, 7-levels are required for an 800V, three-phase AC/DC converter to meet or exceed the bridge-leg efficiency of a 2-level, 400V GaN benchmark for a fixed output filter. The 2.2kW DC/AC hardware demonstrators presented here confirm the necessity of higher-complexity converters, where we show a 2-level, 400V benchmark (99.2% peak efficiency at 18.0kW/l) and a 3-level, 800V (98.8%, 9.1kW/l) and a 7-level, 800V inverter phase-leg (99.03%, 15.8kW/l).

29 September 2020 in IEEE Open Journal of Power Electronics
Verified
Journal Article
Open access
PPPanteleimon Papamanolis
Panteleimon Papamanolis
TGThomas Guillod
Thomas Guillod
FKFlorian Krismer
Florian Krismer
JKJohann Kolar
Johann Kolar
This paper studies the loss-optimal design of a power inductor employed in a 2kW, 400V input DC-DC converter, for a given magnetic core (E55/28/21, N87), and with a focus on optimal choices of key design parameters, i.e., switching frequency, f, relative peak-to-peak current ripple, r, and number of turns, N. The investigation is based on analytical equations and, subsequently, a more detailed semi-numerical model. Surprisingly, the evaluation of the losses calculated in the f-r domain reveals that nearly minimum inductor losses are obtained for a current ripple that is inversely proportional to the frequency, i.e., for a constant inductance, within a wide frequency range, from 200kHz to 1MHz. Furthermore, the investigation reveals a decrease of the losses for increasing frequencies up to 375kHz. The detailed analysis related to these results enables the compilation of a simple two-equations guide for the design of an inductor that achieves close to minimum losses. In a next step, interesting trade-offs are identified based on a study of the design space diversity, e.g., with respect to low cost and increased partial-load efficiency. The findings of this work are experimentally verified, i.e., the losses of three different inductors are measured with an accurate calorimetric method and at four different frequencies, ranging from 150kHz to 700kHz.

17 August 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
PPPanteleimon Papamanolis
Panteleimon Papamanolis
TGThomas Guillod
Thomas Guillod
FKFlorian Krismer
Florian Krismer
JKJohann Kolar
Johann Kolar
An accurate and fast transient calorimetric ferrite core-loss measurement method is proposed in this paper. In contrast to electrical measurements, the accuracy of the calorimetric approach is largely independent of the magnetic excitation and operating frequency. However, accurate values of the thermal capacitance and the temperature of the Core Under Test (CUT) are required. Accurate measurement of the specific heat capacity of the core material can be achieved with a Differential Scanning Calorimeter (DSC) or by using the CUT as a DC electric conductor and measuring its thermal response for known Joule heating. Accurate temperature measurements can be realized with NTC temperature sensors. A thorough uncertainty analysis of the presented method is conducted by identifying the impact of each source of uncertainty in the course of a sensitivity analysis. The results are verified by means of FEM simulations and experiments. Furthermore, a step-by-step description of the workflow for preparing and conducting the experiments is provided. The proposed method is tested experimentally and compared to a state-of-the-art electrical loss measurement method for MnZn N87 and N49 ferrite cores of EPCOS-TDK. In addition, it is used to measure the loss-map of the NiZn ferrite material 67 from Fair-Rite for very high frequencies up to 50MHz.

26 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
PPPanteleimon Papamanolis
Panteleimon Papamanolis
DBDominik Bortis
Dominik Bortis
FKFlorian Krismer
Florian Krismer
David MenziDavid Menzi
David Menzi
JKJohann Kolar
Johann Kolar
A new universal front-end PFC rectifier topology of a battery charger for Electric Vehicles (EVs) is proposed, which allows fast charging at rated and/or full power level in case of 3-phase (Europe) as well as 1-phase (USA) mains supply. In this regard, a conventional 3-phase PFC rectifier would facilitate only one-third of the rated power in case of 1-phase operation. The new topology is based on a two-level six-switch (2LB6) 3-phase boost-type PFC rectifier, which is extended with a diode bridge-leg and additional windings of the Common-Mode (CM) chokes of the EMI filter. Besides this extension of the power circuit, the general design of the new converter is explained, and the generated Differential Mode (DM) and Common Mode (CM) EMI disturbances are investigated for 3-phase and 1-phase operation, resulting in guidelines for the EMI filter design. The EMI performance (CISPR 11 class-B QP) is experimentally verified for 1-phase and 3-phase operation at an output power of 4.5 kW, using a full-scale hardware prototype that implements the proposed extensions for a 2LB6 3-phase boost-type PFC rectifier and that is designed for output power levels of 22 kW and 19 kW in case of 3-phase and 1-phase operation, respectively. Compared to a conventional 2LB6 PFC rectifier, the volume of the extended system increases from 2.7 dm3 to 3.4 dm3, of which 0.5 dm3 is due to the additional dc-link capacitance for buffering the power pulsation with twice the mains frequency occurring for 1-phase operation.

12 December 2020
Verified
Conference Paper
Closed access
JKJohann Kolar
Johann Kolar
JAJon Azurza
Jon Azurza
Spasoje MiricSpasoje Miric
Spasoje Miric
MHMichael Haider
Michael Haider
MGM. Guacci
M. Guacci
DBD. Bortis
D. Bortis
Latest research results on three-phase wide-bandgap (WBG) inverter systems with full-sinewave output voltage filtering are reported. A new soft-switching modulation scheme for two-level 1200 V SiC inverters is described. Furthermore, a new Figure-of-Merit for determining maximum multi-level (ML) bridge-leg efficiency is defined and low-voltage GaN devices are evaluated considering ML flying capacitor (FC) and multi-cell inverter structures. Finally, new integrated-filter buck-boost current DC-link inverter topologies are discussed.