Maria Evelina Fantacci

Prof. Maria Evelina Fantacci

Department of Physics, University of Pisa, 56126 Pisa, Italy
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Medical Image Analysis
Verified
Journal Article
Open access
ASArnaud Arindra Adiyoso Setio
Arnaud Arindra Adiyoso Setio
ATAlberto Traverso
Alberto Traverso
TBThomas de Bel
Thomas de Bel
MBMoira S.N. Berens
Moira S.N. Berens
CBCas van Den Bogaard
Cas van Den Bogaard
CJColin Jacobs
Colin Jacobs
Automatic detection of pulmonary nodules in thoracic computed tomography (CT) scans has been an active area of research for the last two decades. However, there have only been few studies that provide a comparative performance evaluation of different systems on a common database. We have therefore set up the LUNA16 challenge, an objective evaluation framework for automatic nodule detection algorithms using the largest publicly available reference database of chest CT scans, the LIDC-IDRI data set. In LUNA16, participants develop their algorithm and upload their predictions on 888 CT scans in one of the two tracks: 1) the complete nodule detection track where a complete CAD system should be developed, or 2) the false positive reduction track where a provided set of nodule candidates should be classified. This paper describes the setup of LUNA16 and presents the results of the challenge so far. Moreover, the impact of combining individual systems on the detection performance was also investigated. It was observed that the leading solutions employed convolutional networks and used the provided set of nodule candidates. The combination of these solutions achieved an excellent sensitivity of over 95% at fewer than 1.0 false positives per scan. This highlights the potential of combining algorithms to improve the detection performance. Our observer study with four expert readers has shown that the best system detects nodules that were missed by expert readers who originally annotated the LIDC-IDRI data. We released this set of additional nodules for further development of CAD systems.

1 December 2010 in Medical Image Analysis
Verified
Journal Article
Closed access
BGBram van Ginneken
Bram van Ginneken
SASamuel G. Armato
Samuel G. Armato
BHBartjan de Hoop
Bartjan de Hoop
SVSaskia van Amelsvoort-Van de Vorst
Saskia van Amelsvoort-Van de Vorst
TDThomas Duindam
Thomas Duindam
MPMathias Prokop
Mathias Prokop

11 March 2015 in Medical Physics
Verified
Journal Article
Open access
PDF file
ETE. Lopez Torres
E. Lopez Torres
EFE. Fiorina
E. Fiorina
FPF. Pennazio
F. Pennazio
CPC. Peroni
C. Peroni
MSM. Saletta
M. Saletta
PCP. Cerello
P. Cerello
Purpose: M5L, a fully automated computer‐aided detection (CAD) system for the detection and segmentation of lung nodules in thoracic computed tomography (CT), is presented and validated on several image datasets.Methods: M5L is the combination of two independent subsystems, based on the Channeler Ant Model as a segmentation tool [lung channeler ant model (lungCAM)] and on the voxel‐based neural approach. The lungCAM was upgraded with a scan equalization module and a new procedure to recover the nodules connected to other lung structures; its classification module, which makes use of a feed‐forward neural network, is based of a small number of features (13), so as to minimize the risk of lacking generalization, which could be possible given the large difference between the size of the training and testing datasets, which contain 94 and 1019 CTs, respectively. The lungCAM (standalone) and M5L (combined) performance was extensively tested on 1043 CT scans from three independent datasets, including a detailed analysis of the full Lung Image Database Consortium/Image Database Resource Initiative database, which is not yet found in literature.Results: The lungCAM and M5L performance is consistent across the databases, with a sensitivity of about 70% and 80%, respectively, at eight false positive findings per scan, despite the variable annotation criteria and acquisition and reconstruction conditions. A reduced sensitivity is found for subtle nodules and ground glass opacities (GGO) structures. A comparison with other CAD systems is also presented.Conclusions: The M5L performance on a large and heterogeneous dataset is stable and satisfactory, although the development of a dedicated module for GGOs detection could further improve it, as well as an iterative optimization of the training procedure. The main aim of the present study was accomplished: M5L results do not deteriorate when increasing the dataset size, making it a candidate for supporting radiologists on large scale screenings and clinical programs.

28 July 2006 in Medical Physics
Verified
Journal Article
Closed access
PDF file
RBRoberto Bellotti
Roberto Bellotti
FCF. De Carlo
F. De Carlo
Sabina TangaroSabina Tangaro
Sabina Tangaro
GGG. Gargano
G. Gargano
GMG. Maggipinto
G. Maggipinto
Giorgio De NunzioGiorgio De Nunzio
Giorgio De Nunzio

16 October 2006 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Donato CascioDonato Cascio
Donato Cascio
FFF. Fauci
F. Fauci
RMR. Magro
R. Magro
Giuseppe RasoGiuseppe Raso
Giuseppe Raso
RBRoberto Bellotti
Roberto Bellotti
ETE.L. Torres
E.L. Torres
The mammography is the most effective procedure for an early diagnosis of the breast cancer. In this paper, an algorithm for detecting masses in mammographic images will be presented. The database consists of 3762 digital images acquired in several hospitals belonging to the MAGIC-5 collaboration (Medical Applications on a Grid Infrastructure Connection). A reduction of the whole image's area under investigation is achieved through a segmentation process, by means of a ROI Hunter algorithm, without loss of meaningful information. In the following classification step, feature extraction plays a fundamental role: some features give geometrical information, other ones provide shape parameters. Once the features are computed for each ROI, they are used as inputs to a supervised neural network with momentum. The output neuron provides the probability that the ROI is pathological or not. Results are provided in terms of ROC and FROC curves: the area under the ROC curve was found to be AZ=0.862plusmn0.007, and we get a 2.8 FP/Image at a sensitivity of 82%. This software is included in the CAD station actually working in the hospitals belonging to the MAGIC-5 Collaboration

6 July 2009 in Medical Physics
Verified
Journal Article
Closed access
BGBruno Golosio
Bruno Golosio
Giovanni Luca Christian MasalaGiovanni Luca Christian Masala
Giovanni Luca Christian Masala
APAlessio Piccioli
Alessio Piccioli
POPiernicola Oliva
Piernicola Oliva
MCMassimo Carpinelli
Massimo Carpinelli
MTMassimo Torsello
Massimo Torsello