Background: Proton-density fat fraction (PDFF) and T2* of the vertebrae, as well as the cross-sectional area (CSA) of the paraspinal musculature (PSM), have been suggested as biomarkers for bone fragility. The aim of this study was to longitudinally assess changes in PDFF, T2* and CSA of the PSM over 6 months in patients with and without osteoporosis. Methods: Opportunistic bone mineral density (BMD) measurements (BMD < 120 mg/cm3) were obtained from a CT acquired during the clinical routine work up in osteoporotic/osteopenic patients (n = 29, mean age 72.37 ± 10.12 years, 16 women). These patients were frequency-matched for age and sex to subjects with normal BMD values (n = 29). All study patients underwent 3T MR imaging at baseline and 6-month follow up, including spoiled gradient echo sequences for chemical shift encoding-based water-fat separation, from which T2* and PDFF values of the lumbar spine and the PSM were obtained. Moreover, the CSA of the PSM was assessed longitudinally. Changes in T2*, PDFF and CSA over 6 months were calculated for the vertebrae and PSM and associations with baseline BMD values were assessed. Results: The change in CSA of the PSM over 6 months was significantly lower in the osteoporotic/osteopenic group (−91.5 ± 311.7 mm2), compared to the non-osteoporotic group, in which the CSA increased (29.9 ± 164.0 mm2, p = 0.03). In a further analysis, patients with higher vertebral PDFF at baseline showed a significantly stronger increase in vertebral T2*, compared to those patients with lower vertebral PDFF at baseline (0.9 ± 1.6 ms vs. 0.0 ± 1.8 ms, p = 0.04). Moreover, patients with higher PSM PDFF at baseline showed a significantly stronger increase in vertebral T2*, compared to those patients with lower PSM PDFF at baseline (0.9 ± 2.0 ms vs. 0.0 ± 1.3 ms, p = 0.03). Conclusion: The PSM CSA decreased significantly longitudinally in patients with osteoporosis/osteopenia, compared to those without. Additionally, higher vertebral and PSM PDFF at baseline were associated with stronger changes in vertebral bone marrow T2*. Therefore, longitudinal PDFF and T2* mapping may be useful quantitative radiation-free tools for the assessment and prediction of muscle and bone health in patients with suspected osteoporosis/osteopenia.
1 November 2020 in Archives of orthopaedic and trauma surgery
Background: Elective implant removal (IR) accounts for up to 30% of all orthopaedic surgeries. While there is general acceptance about the need of implant removal for obvious reasons, such as infections or implant failure, little is known about the beneficial aspects in cases of minor reasons such as patients’ wish for IR. Therefore, we initiated this study to define patients’ benefit of elective implant removal following plate osteosynthesis of displaced clavicle fractures. Patients and methods: Prospective evaluation of patients was conducted before implant removal and 6 weeks postoperative. Subjective and objective criteria included pain rating on a visual analogue scale (VAS) and active range of motion (ROM) pre- and 6 weeks postoperative. Functional scoring included Constant-Murley Score, DASH (Disabilities of Arm, Shoulder and Hand Score), MSQ (Munich Shoulder Questionnaire) and SPADI (Shoulder Pain and Disability Index). Results: 37 patients were prospectively enrolled in this study and implant removal was performed after 16 ± 6.1 months. No re-fractures nor other complications were detected during routine follow up. Functional outcome increased through all scores (Constant score 73.3 ± 14.6 preoperative to 87.4 ± 12.0 postoperative (p = 0.000), MSQ 85.0 ± 7.3 preoperative to 91.8 ± 9.0 postoperative (p = 0.005), DASH Score 7.4 ± 8.2 preoperative to 5.7 ± 9.5 postoperative (p = 0.414), SPADI 93.4 ± 6.6 preoperative to 94.0 ± 10.1 postoperative (p = 0.734). Conclusions: Discomfort during daily activities or performing sports as well as limited range of motion were the main reasons for patients’ wish for implant removal. We found increased functional outcome parameters and decreased irritation after implant removal. Therefore we suggest implant removal in case of patients’ wish and completed fracture consolidation. Trial registration: Trial registration no: NCT04343118, Retrospective registered: www.clinicaltrials.gov.
To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with suspected shoulder pathology. 3 T MRI of the shoulder including a 3D T1-weighted gradient echo sequence was performed in 25 patients (mean age 52.4 ± 18 years, 13 women) with suspected shoulder pathology. Subsequently a cone-beam forward projection algorithm was used to obtain intensity-inverted CT-like images and simulated radiographs. Two radiologists evaluated the simulated images separately and independently using the conventional radiographs as the standard of reference, including measurements of the image quality, acromiohumeral distance, critical shoulder angle, degenerative joint changes and the acromial type. Additionally, the CT-like MR images were evaluated for glenoid defects, subcortical cysts and calcifications. Agreement between the MR-derived simulated radiographs and conventional radiographs was calculated using Cohen’s Kappa. Measurements on simulated radiographs and conventional radiographs overall showed a substantial to almost perfect inter- and intra-rater agreement (κ = 0.69–1.00 and κ = 0.65–0.85, respectively). Image quality of the simulated radiographs was rated good to excellent (1.6 ± 0.7 and 1.8 ± 0.6, respectively) by the radiologists. A substantial agreement was found regarding diagnostically relevant features, assessed on Y- and anteroposterior projections (κ = 0.84 and κ = 0.69 for the measurement of the CSA; κ = 0.95 and κ = 0.60 for the measurement of the AHD; κ = 0.77 and κ = 0.77 for grading of the Samilson-Prieto classification; κ = 0.83 and κ = 0.67 for the grading of the Bigliani classification, respectively). In this proof-of-concept study, clinically relevant features of the shoulder joint were assessed reliably using MR-derived CT-like images and simulated radiographs with an image quality equivalent to conventional radiographs. MR-derived CT-like images and simulated radiographs may provide useful diagnostic information while reducing the amount of radiation exposure.
22 September 2023 in European Journal of Medical Research
Background: Patella fractures are relatively rare fractures and only little is known about the postoperative return to sports after patella fractures. Methods: This retrospective study presents information on functional outcome after operative treatment of patella fractures as well as time until return to sports and patients’ complaints after open-reduction internal-fixation (ORIF) of patella fractures. Results: Overall, 39 patients after ORIF of patella fractures were evaluated at our Level-I trauma center with a mean follow-up of 42 months. The mean time until return to sports was 7 ± 3.9 months. No significant difference was found for functional outcome with respect to body mass index (BMI) or age. Fracture consolidation was accomplished after a mean of 6.9 ± 2.9 months besides a relatively low complication rate of 5.1% (n = 2). Conclusion: The results demonstrate a high return to sports rate of 90.3%. However, only 51.6% were able to perform sports on their pre-injury level or above. Trial Registration The study was retrospectively registered at DRKS (No: DRKS00031146).
Background and objectives: Electromobility has become increasingly popular. In 2001, Segway personal transporters (Segway) were established for tourists, and e-scooters have been in use since their approval in 2019. The aim of this study was to analyze and compare the types of injuries directly related to the use of Segways and e-scooters, respectively, in a German city and to phrase potential safety advice. Materials and Methods: All patients presenting to our emergency department after Segway incidents were retrospectively analyzed and compared with the prospectively collected cohort of patients following e-scooter incidents. Presented injuries were analyzed by body region and injury severity score (ISS). Epidemiological data were collected. Results: Overall, 171 patients were enrolled. The Segway group included 56 patients (mean age 48 years), and the e-scooter group consisted of 115 patients (mean age 33.9 years). Head injuries (HI) occurred in 34% in the Segway group compared to 52% in the e-scooter group. The ISS was approximately equal for both groups (mean ISS Segway group: 6.9/e-scooter group: 5.6). Conclusions: Since the e-scooter group presented a high number of HI along with a higher likelihood and greater severity of HI, mandatory use of helmets is suggested.
(1) Background: As age in western populations is rising, so too are fractures, e.g., of the distal fibula. The aim of this study was to find out whether a novel, minimally invasive intramedullary osteosynthesis technique for the treatment of distal fibula fractures in elderly patients results in not only a reduction of postoperative complications, but also a shorter hospitalization time, an improved clinical outcome, and preserved autonomy in geriatric trauma patients. (2) Methods: In this prospective study, the results following surgical treatment for distal fibula fractures in geriatric patients after using DePuy Synthes® one-third semitubular plate (Group I) or a minimally invasive intramedullary photodynamic Bone StabilizationSystem (IlluminOss®) (Group II) were compared at 6 weeks, 12 weeks, 6 months, and 1 year after initial treatment. (3) Results: Significant improvement regarding clinical outcome was shown in Group II 6 and 12 weeks after surgery. (4) Conclusions: Our study results demonstrate that the use of this new intramedullary stabilization system in combination with an immediate postoperative weight bearing seems to be a safe and stable treatment option for ankle fractures in geriatric patients, especially in the early stages of recovery.