Evgeniia Sokolova

Ms. Evgeniia Sokolova

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2021 in Biology
Verified
Journal Article
Open access
PDF file
Sergey TaskaevSergey Taskaev
Sergey Taskaev
EBEvgeny Berendeev
Evgeny Berendeev
MBMarina Bikchurina
Marina Bikchurina
TBTimofey Bykov
Timofey Bykov
DKDmitrii Kasatov
Dmitrii Kasatov
GVGleb Dmitrievich Verkhovod
Gleb Dmitrievich Verkhovod
A compact accelerator-based neutron source has been proposed and created at the Budker Institute of Nuclear Physics in Novosibirsk, Russia. An original design tandem accelerator is used to provide a proton beam. The proton beam energy can be varied within a range of 0.6–2.3 MeV, keeping a high-energy stability of 0.1%. The beam current can also be varied in a wide range (from 0.3 mA to 10 mA) with high current stability (0.4%). In the device, neutron flux is generated as a result of the 7Li(p,n)7Be threshold reaction. A beam-shaping assembly is applied to convert this flux into a beam of epithermal neutrons with characteristics suitable for BNCT. A lot of scientific research has been carried out at the facility, including the study of blistering and its effect on the neutron yield. The BNCT technique is being tested in in vitro and in vivo studies, and the methods of dosimetry are being developed. It is planned to certify the neutron source next year and conduct clinical trials on it. The neutron source served as a prototype for a facility created for a clinic in Xiamen (China).

12 December 2017 in Metals
Verified
Journal Article
Open access
PDF file
ABAlexander Badrutdinov
Alexander Badrutdinov
TBTimofey Bykov
Timofey Bykov
SGSergey A Gromilov
Sergey A Gromilov
YHYasuo Higashi
Yasuo Higashi
DKDmitrii Kasatov
Dmitrii Kasatov
Sergey TaskaevSergey Taskaev
Sergey Taskaev
A vacuum-insulated tandem accelerator was used to observe in situ blistering during 2-MeV proton irradiation of metallic samples to a fluence of up to 6.7 × 1020 cm−2. Samples consisting of copper of different purity, tantalum and tantalum-copper compounds were placed on the proton beam path and forced to cool. The surface state of the samples was observed using a charge-coupled device camera with a remote microscope. Thermistors, a pyrometer and an infrared camera were applied to measure the temperature of the samples during irradiation. After irradiation, the samples were analyzed on an X-ray diffractometer, laser and electron microscopes. The present study describes the experiment, presents the results obtained and notes their relevance and significance in the development of a lithium target for an accelerator-based neutron source, for use in boron neutron capture therapy of cancer.

24 August 2021 in Biology
Verified
Journal Article
Open access
PDF file
MBMarina Bikchurina
Marina Bikchurina
TBTimofey Bykov
Timofey Bykov
DKDmitrii Kasatov
Dmitrii Kasatov
IKIaroslav Kolesnikov
Iaroslav Kolesnikov
Aleksandr MakarovAleksandr Makarov
Aleksandr Makarov
Sergey TaskaevSergey Taskaev
Sergey Taskaev
A compact accelerator-based neutron source has been proposed and created at the Budker Institute of Nuclear Physics in Novosibirsk, Russia. An original design tandem accelerator is used to provide a proton beam. The neutron flux is generated as a result of the 7Li(p,n)7Be threshold reaction using the solid lithium target. A beam shaping assembly is applied to convert this flux into a beam of epithermal neutrons with characteristics suitable for BNCT. The BNCT technique is being tested in in vitro and in vivo studies, and dosimetry methods are being developed. Currently, the BNCT technique has entered into clinical practice in the world: after successful clinical trials, two clinics in Japan began treating patients, and four more BNCT clinics are ready to start operating. The neutron source proposed at the Budker Institute of Nuclear Physics served as a prototype for a facility created for a clinic in Xiamen (China). It is planned to equip the National Medical Research Center of Oncology (Moscow, Russia) and National Oncological Hadron Therapy Center (Pavia, Italy) with the same neutron sources. Due to the impending use of an accelerator neutron source for treating patients, the validation of the neutron yield of the 7Li(p,n)7Be reaction in lithium metal targets is required. The theoretical neutron yield has not been evaluated experimentally so far.

16 September 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Alexander ZaboronokAlexander Zaboronok
Alexander Zaboronok
Sergey TaskaevSergey Taskaev
Sergey Taskaev
OVOlga Volkova
Olga Volkova
LMLudmila Mechetina
Ludmila Mechetina
Anna KasatovaAnna Kasatova
Anna Kasatova
AMAkira Matsumura
Akira Matsumura
Boron neutron capture therapy (BNCT) is an anticancer modality realized through 10B accumulation in tumor cells, neutron irradiation of the tumor, and decay of boron atoms with the release of alpha-particles and lithium nuclei that damage tumor cell DNA. As high-LET particle release takes place inside tumor cells absorbed dose calculations are difficult, since no essential extracellular energy is emitted. We placed gold nanoparticles inside tumor cells saturated with boron to more accurately measure the absorbed dose. T98G cells accumulated ~50 nm gold nanoparticles (AuNPs, 50 µg gold/mL) and boron-phenylalanine (BPA, 10, 20, 40 µg boron-10/mL), and were irradiated with a neutron flux of 3 × 108 cm−2s−1. Gamma-rays (411 keV) emitted by AuNPs in the cells were measured by a spectrometer and the absorbed dose was calculated using the formula D = (k × N × n)/m, where D was the absorbed dose (GyE), k—depth-related irradiation coefficient, N—number of activated gold atoms, n—boron concentration (ppm), and m—the mass of gold (g). Cell survival curves were fit to the linear-quadratic (LQ) model. We found no influence from the presence of the AuNPs on BNCT efficiency. Our approach will lead to further development of combined boron and high-Z element-containing compounds, and to further adaptation of isotope scanning for BNCT dosimetry.

1 September 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
TBTimofey Bykov
Timofey Bykov
DKDmitrii Kasatov
Dmitrii Kasatov
IKIaroslav Kolesnikov
Iaroslav Kolesnikov
AKAlexey Koshkarev
Alexey Koshkarev
Aleksandr MakarovAleksandr Makarov
Aleksandr Makarov
Sergey TaskaevSergey Taskaev
Sergey Taskaev

1 January 2021 in Instruments and Experimental Techniques
Verified
Journal Article
Closed access
PDF file
AMA. N. Makarov
A. N. Makarov
ESEvgeniia Sokolova
Evgeniia Sokolova
Sergey TaskaevSergey Taskaev
Sergey Taskaev
The results of measurements of the luminescence spectrum of lithium when it is irradiated with a proton beam with an energy of 2 MeV are presented. The operational diagnostics for monitoring the position of the proton beam on a lithium target, which is used in neutron generation, has been developed and put into operation.