Software for analyzing pseudotranslational sublattices (PTSs) in crystal structures is described. This software makes it possible to enumerate triads of reflections, sort them out with respect to different characteristics, calculate linear and angular subcell parameters, and express the sublattice vectors in terms of the initial lattice vectors. The solution to the most widespread problems is illustrated by the example of the well-known [Ru(NH3)6]Cl3 and [CuL](NO3)(ReO4) crystal structures (L is 4,6,6-trimethyl-1,9-diamino-3,7-diazanon-3-en) and the structure of mineral iltisite, which is still unknown. In all cases we observed a tendency of crystal structures to have a higher symmetry, which was noted by Academician Belov in his time. “A material that in fact crystallizes in a lower system is nevertheless rather close (in its crystalline form) to numerical relations characteristic of a higher system.” (Belov [1, p. 227])
In this work, the sensor response of MPcFx (M = Cu, Co, Zn; x = 0, 4, 16) films toward gaseous NH3 (10–50 ppm) was studied by a chemiresistive method and compared to that of unsubstituted MPc films to reveal the effects of central metals and F-substituents on the sensing properties. A combination of atomic force microscopy and X-ray diffraction techniques have been used to elucidate the structural features of thin MPcFx films deposited by organic molecular beam deposition. It has been shown that the sensor response of MPcF4 films to ammonia is noticeably higher than that of MPc films, which is in good correlation with the values of binding energy between the metal phthalocyanine and NH3 molecules, as calculated by the density functional theory (DFT) method. At the same time, in contrast to the DFT calculations, MPcF16 demonstrated the lesser sensor response compared with MPcF4, which appeared to be connected with the different structure and morphology of their films. The ZnPcF4 films were shown to exhibit a sensitivity to ammonia up to concentrations as low as 0.1 ppm, and can be used for the selective detection of ammonia in the presence of some reducing gases and volatile organic compounds. Moreover, the ZnPcF4 films can be used for the detection of NH3 in the gas mixture simulating exhaled air (N2 76%, O2 16%, H2O 5%, and CO2 3%).
A vacuum-insulated tandem accelerator was used to observe in situ blistering during 2-MeV proton irradiation of metallic samples to a fluence of up to 6.7 × 1020 cm−2. Samples consisting of copper of different purity, tantalum and tantalum-copper compounds were placed on the proton beam path and forced to cool. The surface state of the samples was observed using a charge-coupled device camera with a remote microscope. Thermistors, a pyrometer and an infrared camera were applied to measure the temperature of the samples during irradiation. After irradiation, the samples were analyzed on an X-ray diffractometer, laser and electron microscopes. The present study describes the experiment, presents the results obtained and notes their relevance and significance in the development of a lithium target for an accelerator-based neutron source, for use in boron neutron capture therapy of cancer.
We propose a technique for the refinement of unit cell parameters (UCPs) using a single crystal diffractometer equipped with a flat-panel area detector. The technique is based on choosing Kα1 components of X-ray radiation when processing diffraction reflections. The capabilities of the technique are demonstrated on [NiEn3]MoO4 single crystals. In two independent experiments, the difference between 2θexp and 2θcalc did not exceed 0.02° while the reproducibility of unit cell parameters was at least 0.008 Å.
A technique for the refinement of unit cell parameters using doublet reflections of the external reference is described. The diffraction reflection of the studied crystal is chosen in such a way that it falls within the region between spectral lines Kα1 and Kα2 of the corresponding doublet of the external reference (in this work, a Si reference). The possibilities of this technique are demonstrated on Ge, InSb, and diamond single crystals. It is shown that unit cell parameters can be measured on standard laboratory diffractometers with a relative error less than 5·10–5.