A third-order G m -C Chebyshev low-pass filter based on a novel gain-boosted tunable transconductor is presented. The transconductor employs local negative feedback for linearization controlling the drain voltage of the input transistors biased in the triode region. The gain boosted feedback amplifier is based on quasi-floating gate MOS transistors and its adjustable biasing current allows tuning the cutoff frequency of the filter. The filter is intended to be used in the baseband section of a zero-IF bluetooth low energy receiver and it has been fabricated in a standard 0.13-μm CMOS technology with a nominal cutoff frequency of 500 kHz. The power consumption of the overall filter is 450 μW with a supply voltage of 1.2 V. The measurement results show a third-order intermodulation distortion of -46.4 dB for two input tones located at the passband of the filter. The filter occupies a silicon area of 0.08 mm 2 .
1 May 2012 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
For the monitoring of bone regeneration processes, the instrumentation of the fixation is an increasingly common technique to indirectly measure the evolution of bone formation instead of ex vivo measurements or traditional in vivo techniques, such as X-ray or visual review. A versatile instrumented external fixator capable of adapting to multiple bone regeneration processes was designed, as well as a wireless acquisition system for the data collection. The design and implementation of the overall architecture of such a system is described in this work, including the hardware, firmware, and mechanical components. The measurements are conditioned and subsequently sent to a PC via wireless communication to be in vivo displayed and analyzed using a developed real-time monitoring application. Moreover, a model for the in vivo estimation of the bone callus stiffness from collected data was defined. This model was validated in vitro using elastic springs, reporting promising results with respect to previous equipment, with average errors and uncertainties below 6.7% and 14.04%. The devices were also validated in vivo performing a bone lengthening treatment on a sheep metatarsus. The resulting system allowed the in vivo mechanical characterization of the bone callus during experimentation, providing a low-cost, simple, and highly reliable solution.
This paper presents a study about hardware attacking and clock signal vulnerability. It considers a particular type of attack on the clock signal in the I2C protocol, and proposes the design of a new sensor for detecting and defending against this type of perturbation. The analysis of the attack and the defense is validated by means of a configurable experimental platform that emulates a differential drive robot. A set of experimental results confirm the interest of the studied vulnerabilities and the efficiency of the proposed sensor in defending against this type of situation.