Rafael Lopez-Ahumada

Dr. Rafael Lopez-Ahumada

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlberto J. Molina-Cantero
Alberto J. Molina-Cantero
JCJuan Antonio Castro-Garcia
Juan Antonio Castro-Garcia
Fernando Gomez-BravoFernando Gomez-Bravo
Fernando Gomez-Bravo
RLRafael Lopez-Ahumada
Rafael Lopez-Ahumada
RJRaúl Jiménez-Naharro
Raúl Jiménez-Naharro
SBSantiago Berrazueta-Alvarado
Santiago Berrazueta-Alvarado
(1) Goals: The purpose of this study was to analyze the feasibility of using the information obtained from a one-channel electro-encephalography (EEG) signal to control a mouse pointer. We used a low-cost headset, with one dry sensor placed at the FP1 position, to steer a mouse pointer and make selections through a combination of the user’s attention level with the detection of voluntary blinks. There are two types of cursor movements: spinning and linear displacement. A sequence of blinks allows for switching between these movement types, while the attention level modulates the cursor’s speed. The influence of the attention level on performance was studied. Additionally, Fitts’ model and the evolution of the emotional states of participants, among other trajectory indicators, were analyzed. (2) Methods: Twenty participants distributed into two groups (Attention and No-Attention) performed three runs, on different days, in which 40 targets had to be reached and selected. Target positions and distances from the cursor’s initial position were chosen, providing eight different indices of difficulty (IDs). A self-assessment manikin (SAM) test and a final survey provided information about the system’s usability and the emotions of participants during the experiment. (3) Results: The performance was similar to some brain–computer interface (BCI) solutions found in the literature, with an averaged information transfer rate (ITR) of 7 bits/min. Concerning the cursor navigation, some trajectory indicators showed our proposed approach to be as good as common pointing devices, such as joysticks, trackballs, and so on. Only one of the 20 participants reported difficulty in managing the cursor and, according to the tests, most of them assessed the experience positively. Movement times and hit rates were significantly better for participants belonging to the attention group. (4) Conclusions: The proposed approach is a feasible low-cost solution to manage a mouse pointer.

1 November 2014 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
TSTrinidad Sanchez
Trinidad Sanchez
FMFernando MunozChavero
Fernando MunozChavero
JGJuan Antonio Gómez-Galán
Juan Antonio Gómez-Galán
RLRafael Lopez-Ahumada
Rafael Lopez-Ahumada
Ramon Gonzalez CarvajalRamon Gonzalez Carvajal
Ramon Gonzalez Carvajal

1 December 2001 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
RLRafael Lopez-Ahumada
Rafael Lopez-Ahumada
RRRafael Rodríguez-Macías
Rafael Rodríguez-Macías

5 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
RLRafael Lopez-Ahumada
Rafael Lopez-Ahumada
RJRaúl Jiménez-Naharro
Raúl Jiménez-Naharro
Fernando Gomez-BravoFernando Gomez-Bravo
Fernando Gomez-Bravo
Eye blink artifacts in electroencephalographic (EEG) signals have been used in multiple applications as an effective method for human–computer interaction. Hence, an effective and low-cost blinking detection method would be an invaluable aid for the development of this technology. A configurable hardware algorithm, described using hardware description language, for eye blink detection based on EEG signals from a one-channel brain–computer interface (BCI) headset was developed and implemented, showing better performance in terms of effectiveness and detection time than manufacturer-provided software.

1 June 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JGJuan Antonio Gómez-Galán
Juan Antonio Gómez-Galán
RLRafael Lopez-Ahumada
Rafael Lopez-Ahumada
TST. Sánchez-Rodríguez
T. Sánchez-Rodríguez
MSManuel Sánchez-Raya
Manuel Sánchez-Raya
RJRaúl Jiménez-Naharro
Raúl Jiménez-Naharro
I. MartelI. Martel
I. Martel

4 March 2014 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JGJuan Antonio Gómez-Galán
Juan Antonio Gómez-Galán
RLRafael Lopez-Ahumada
Rafael Lopez-Ahumada
TST. Sanchez-Rodriguez
T. Sanchez-Rodriguez
Antonio TorralbaAntonio Torralba
Antonio Torralba
RCR. G. Carvajal
R. G. Carvajal
I. MartelI. Martel
I. Martel
This paper presents a low voltage, low power readout front-end system implemented in 130 nm CMOS technology. A conventional architecture that consists of charge sensitive amplifier, pole/zero cancellation and shaper has been used. The work focuses on the design of novel circuit topologies in low voltage environment minimizing the power consumption in modern deep submicron CMOS technologies. An operational amplifier with rail-to-rail output swing that uses a gain boosting technique and class-AB output stage without extra power consumption has been used for the shaper. The circuit combines excellent performances with simplicity of design and suitability for low voltage operation. The system is intended to work with silicon detectors for nuclear physics applications and is optimized to match an input capacitance of 10 pF. The system features a peaking time of 500 ns, a power dissipation of 1.57 mW/channel and an equivalent noise charge of 201 e - .