(1) Background: Research has demonstrated that early intervention for children who are hard-of-hearing (CHH) facilitates improved language development. Early speech perception abilities may impact CHH outcomes and guide future intervention. The objective of this study was to examine the use of a conditioned head turn (CHT) task as a measure of speech discrimination in CHH using a clinically feasible protocol. (2) Methods: Speech perception was assessed for a consonant and vowel contrast among 57 CHH and 70 children with normal hearing (CNH) aged 5–17 months using a CHT paradigm. (3) Results: Regardless of hearing status, 74% of CHH and 77% of CNH could discriminate /a-i/, and 55% of CHH and 56% of CNH could discriminate /ba-da/. Regression models revealed that both CHH and CNH performed better on /ba-da/ at 70 dBA compared to 50 dBA. Performance by hearing age showed no speech perception differences for CNH and children with mild hearing loss for either contrast. However, children with hearing losses ≥ 41 dB HL performed significantly poorer than CNH for /a-i/. (4) Conclusions: This study demonstrates the clinical feasibility of assessing early speech perception in infants with hearing loss and replicates previous findings of speech perception abilities among CHH and CNH.
Background: Speech discrimination assessments are used to validate amplification fittings of older children who are hard of hearing (CHH). Unfortunately, speech discrimination is not assessed clinically 24 months and in turn no studies have investigated the relationship between speech discrimination during infancy and later language development among CHH. Objective: To examine the relationship between an individual infant’s speech discrimination measured at 9 months and their expressive/receptive spoken language at 30 months for children with normal hearing (CNH) and CHH. Methods: Behavioral speech discrimination was assessed at 9 months and language assessments were conducted at 16, 24, and 30 months using a parent questionnaire, and at 30 months using the Mullen Scales of Early Learning among 90 infants (49 CNH; 41 CHH). Results: Conditioned Head Turn (CHT) performance for /a-i/ significantly predicted expressive and receptive language at 30 months across both groups. Parental questionnaires were also predictive of later language ability. No significant differences in speech discrimination or language outcomes between CNH and CHH were found. Conclusions: This is the first study to document a positive relationship between infant speech discrimination and later language abilities in both early-identified CHH and CNH.
Spectral weighting functions (SWF) were measured for lateralization of complex tones via interaural time difference (ITD), with higher frequency resolution (1/4-octave) compared to prior studies. SWFs revealed a region of dominant ITD weight spanning 400–1000 Hz on average and dropping precipitously between 1000 and 1400 Hz. SWF peak frequencies varied across individuals and favored lower frequencies on trials which presented larger overall ITD values (±200 μs), consistent with the expected relationship between frequency and the range of unambiguous ITD.
This research compares speech discrimination abilities between 17 children who are hard-of-hearing (CHH) and 13 children with normal hearing (CNH), aged 9 to 36 months, using either a conditioned head turn (CHT) or condition play paradigm, for two phoneme pairs /ba-da/ and /sa-ʃa/. As CHH were tested in the aided and unaided conditions, CNH were also tested on each phoneme contrast twice to control for learning effects. When speech discrimination abilities were compared between CHH, with hearing aids (HAs), and CNH, there were no statistical differences observed in performance on stop consonant discrimination, but a significant statistical difference was observed for fricative discrimination performance. Among CHH, significant benefits were observed for /ba-da/ speech discrimination while wearing HAs, compared to the no HA condition. All CHH were early-identified, early amplified, and were enrolled in parent-centered early intervention services. Under these conditions, CHH demonstrated the ability to discriminate speech comparable to CNH. Additionally, repeated testing within 1-month did not result in a change in speech discrimination scores, indicating good test–retest reliability of speech discrimination scores. Finally, this research explored the question of infant/toddler listening fatigue in the behavioral speech discrimination task. The CHT paradigm included returning to a contrast (i.e., /a-i/) previously shown to be easier for both CHH and CNH to discriminate to examine if failure to discriminate /ba-da/ or /sa-ʃa/ was due to listening fatigue or off-task behavior.
6 March 2025 in International Journal of Audiology
To reduce the amplitude of stimulus artefacts present in bone conduction auditory brainstem response (BC ABR) measurements. Electromagnetic shielding was applied to the surface of a clinical BC transducer. A foam pad was also placed on the shielded mastoid-contacting plate of the transducer. Acoustic impacts of these modifications were evaluated using an artificial mastoid. Unmodified and modified (shielding with pad) transducers were then used to elicit BC ABRs in adults and infants. Stimulus artefact amplitudes were compared across transducers. Six adults (24-42 years old) and 13 typically developing infants (mean age 48.77 days) with no sensorineural hearing loss. Shielding alone slightly decreased acoustic transducer output above approximately 1000 Hz. The addition of a foam pad largely negated this loss, while lower-frequency (500-1000 Hz) acoustic transducer output was slightly increased. The modified transducer produced significantly less stimulus artefact, although variation across subjects was also evident. In a clinical setting, Wave V was detected at similar rates for both transducers. While artefact was not eliminated, direct attenuation of artefact amplitude (versus software-based mitigation strategies) could simplify BC ABR and other evoked potential measurement protocols and support more stringent artefact rejection criteria to yield more informative recordings.