Irshad Ullah

Dr. Irshad Ullah


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2022 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
MRMamoon Ur Rashid
Mamoon Ur Rashid
IUIrshad Ullah
Irshad Ullah
MMMuhammad Mehran
Muhammad Mehran
MBM. N. R. Baharom
M. N. R. Baharom
FKFaisal khan
Faisal khan

23 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
RARizwan Ahmad
Rizwan Ahmad
Mahmoud KassasMahmoud Kassas
Mahmoud Kassas
CAChokri B. Ahmed
Chokri B. Ahmed
FKFaisal khan
Faisal khan
SKSikandar Khan
Sikandar Khan
IUIrshad Ullah
Irshad Ullah
Electrical grounding is an indispensable part of the power system network. The grounding system is mainly affected by grounding resistance and the nature of the soil. High ground resistance produces the phenomenon of soil ionization, surface arching, and back flashover. A conventional grounding system requires the deep digging of electrodes, thus creating maintenance difficulties. This research work focuses on the safe operation of an electric power system from external and internal impulses arising due to lightning strikes or short circuits. The study proposes an application of mineral samples as grounding materials, and bentonite is used as backfilling material in portable grounding systems. A detailed experimental analysis was conducted under controlled conditions to evaluate the performance of selected materials in high-resistance soil. The problem of a deeply driven electrode is addressed by designing the portable grounding system. The study results demonstrate that the proposed portable grounding system could be installed in troubled environments such as forests, deserts, and rocky terrains. To measure the breakdown voltages of the proposed samples, X-ray Diffraction (XRD) analysis and other laboratory tests were conducted. The electric field intensities are extracted through Finite Element Analysis (FEA). The experimental and simulation findings show the expected performance of mineral samples under various operating conditions. The findings of this study can guide the practitioners for safe and efficient operations of portable electrical grounding systems.

10 February 2018 in Wireless Personal Communications
Verified
Journal Article
Closed access
PDF file
IUIrshad Ullah
Irshad Ullah
MBM. N. R. Baharom
M. N. R. Baharom
HAH. Ahmad
H. Ahmad
FWFazli Wahid
Fazli Wahid
HLH. M. Luqman
H. M. Luqman
BDB. Das
B. Das

3 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
MAMatiullah Ahsan
Matiullah Ahsan
NBNor Ramdon Bin Baharom
Nor Ramdon Bin Baharom
ZZZainab Zainal
Zainab Zainal
LMLuqman Hakim Mahmod
Luqman Hakim Mahmod
IUIrshad Ullah
Irshad Ullah
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
High-voltage transmission technology has advanced quickly with the overall development and increased use of renewable energy. More demands on the insulating system are made when high-voltage power systems evolve. One of the significant factors is the sharp rise in population density, which led to the high demand for electricity. Right-of-way infringement is a problem that frequently occurs these days. Transmission is done over a rated capacity; as a result, the transmission line heats up, the insulation ages, and the electric field becomes distorted. The insulating system is prone to fail too soon when the operating voltage inverses or when there is a significant temperature differential. Environmentally friendly insulating materials have received much attention recently. A synergistic optimisation of heat resistance properties, mechanical properties, and dielectric properties must be accomplished before these materials can be used in high-voltage transmission systems. They must also withstand harsh electrical and thermal shocks such as overvoltage and short-circuit faults. One of the developments that has become a popular research topic is the constantly evolving tower design. This review article presents advancements in cross-arm technology in high-voltage transmission systems to elaborate on the limitations and contributions of different research work.

9 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
IUIrshad Ullah
Irshad Ullah
MBMohd Nor Ramdon Bin Bahrom
Mohd Nor Ramdon Bin Bahrom
MKMuhammad Adeel Khan
Muhammad Adeel Khan
AQAzhar Qazi
Azhar Qazi
In this paper, upward leader initiation and the probability of lightning flashes on different air terminal were analyzed in detail. With the growing global warming, lightning flash density has increased abruptly, especially in tropical countries. Upward leaders are the critical elements to be considered for defining comprehensive protective measures against lightning during thunderstorms. This article presents the lightning flashover phenomenon on scaled buildings with installed lightning rods. Moreover, the electric field and initialization of upward leaders from Lightning Air Terminals (LATs) were analyzed in detail using Ansys Maxwell as a simulation tool. For the experimental work, a high-voltage impulse generator was used. The air gap between the lightning rods and the top electrode was kept constant in all scaled structures. The purpose of using an identical air gap was to study the upward leader and its electric field for all structures. The effects of the upward leaders on the electric field plots are explained in detail and allowed the determination of the electric field’s intensity around each air terminal for the provided air gap between the tip of the rod and the top electrode. A low-cost lightning protection system was taken into account, as the economic crisis is worsening with time. A Franklin rod was used as the primary protection device for the initiation of the upward streamer. The experimental results were obtained in Malaysian weather conditions based on standard values of temperature and pressure. The study presented in this article shows that based on the experimental work, field plots were obtained for both the air insulation scenario and the condition when the upward leader was incepted. The simulation results showed a firm agreement with the measured values. Similarly, by upward leader inception, the strikes could be predicted accurately on every installed air terminal.

1 July 2018 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
IUIrshad Ullah
Irshad Ullah
MBMnr Baharom
Mnr Baharom
HAH. Ahmad
H. Ahmad
HLH.M. Luqman
H.M. Luqman
ZZZainab Zainal
Zainab Zainal
Lightning strikes affect the building structures by producing high electric field on the surface and around the building structure. Lightning air terminal is a traditional enemy of the thunder storm as it captures the lightning flashes. Effect of lightning flash on the building structure when the lightning air terminal was not installed and when it was installed on different building structure was studied in this paper. Similarly most of the time Lightning Air Terminal (LAT) bypasses take palce on different building structures and thus a lot of building structures get damage. The phenomenon of bypasses was also studied in this paper. When thunder storm strikes a building the electric field effect is propagated throughout the building surface and it damages the entire building. When the air terminal is places on the corners/edges it captures the lightning flashes on certain points and discharges it into the ground and the building remains safe. This phenomenon was studied in detail in this paper and it was proved that by installing the air terminal the remaining building structure was safe and the electric field intensity was concentrated on the installed air terminal rather than the whole roof top and the rest of the building.