Matiullah Ahsan

Mr. Matiullah Ahsan

Universiti Tun Hussein Onn Malaysia, Batu Pahat, Johor, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2020 in IEEE Access
Verified
Journal Article
Open access
IKIhsan Ullah Khalil
Ihsan Ullah Khalil
AUAzhar Ul-Haq
Azhar Ul-Haq
YMYousef Mahmoud
Yousef Mahmoud
MJMarium Jalal
Marium Jalal
MAMuhammad Aamir
Muhammad Aamir
KMKhalid Mehmood
Khalid Mehmood
Faults detection and analysis in PV system are considered critical for ensuring safety and increasing output power of PV arrays. PV faults do not only reduce output power and efficiency but also lessen the working life time of a system. Most common and chronic PV faults are line to line, line to ground, shadowing fault, and arc fault while less common and acute faults are hotspot, degradation, bypass diode, and connection faults. Event of PV fault detection failures, such as most recent in Mount Holly, USA in 2011 evinced the improvement in current fault detection and mitigation techniques to shrink such failures. There are various limitations in the existing fault detection techniques, as identified in this paper, which may cause misdetection of the faults. This paper is focused on mathematical formulation of various PV faults and lead to the latter’s critical analysis in terms of efficiency, accuracy, complexity, and reliability. The presented work also helps to identify nature and causes of occurrence of a PV fault. This research work serves as a special set of references and recommendations for researchers and PV manufacturing industry to improve fault detection prospects in solar PV systems.

1 October 2018
Verified
Conference Paper
Closed access
IKIhsan Ullah Khalil
Ihsan Ullah Khalil
MAMatiullah Ahsan
Matiullah Ahsan
IUIrshad Ullah
Irshad Ullah
AAArbab Adnan
Arbab Adnan
NKNaveed Khan
Naveed Khan
SNShah Nawaz
Shah Nawaz
solar energy is become more eminent source of energy among renewable energy sources in order to overcome power shortfall. Energy Storage is also an important subject of renewable power generation, Lithium-Ion (Li-Ion) battery is preferred choice among all batteries due to some advantages, e.g. comparatively better charging and discharging performance, high energy and charge density, and more favorable power support. Battery safety and reliability are ensured usually by battery management system (BMS). Among various parameters in a BMS, State of Charge (SOC) of Li-Ion cells is a key indicator which represents the ratio of the stored energy in the battery to the total energy that the battery can contain. In this paper, state of the art SOC estimation using Ampere-hour (Ah) counting and Extended Kalman filter (EKF) methods have been presented. First, EKF for estimating SOC of Li-Ion battery is mathematically designed. Then electrical battery model is implemented using Ah counting and EKF in MATLAB/Simulink. A comparison of the two methods is given which indicates that the SOC evaluation of the battery using EKF is more accurate than Ah counting method. The error observed from the results of EKF is less than 1%.

13 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
IHimran hussain
imran hussain
IKIhsan Ullah Khalil
Ihsan Ullah Khalil
AIAqsa Islam
Aqsa Islam
MAMatiullah Ahsan
Matiullah Ahsan
TITaosif Iqbal
Taosif Iqbal
NUNasim Ullah
Nasim Ullah
Solar photovoltaic PV plants worldwide are continuously monitored and carefully protected to ensure safe and reliable operation through detecting and isolating faults. Faults are very common in modern solar PV systems which interrupt normal system operation adversely affecting the performance of the PV systems. When undetected, faults not only cause significant reduction in the efficiency and life span of the PV system, but also result in damage and fire hazards compromising their reliability. Therefore, early fault detection and diagnosis of photovoltaic plants is a necessity for safe and reliable operation required for growing solar PV systems. Unfortunately, several recent fire incidents have been reported recently caused by undetected faults in solar PV systems. Motivated by this challenge, this paper, utilizing a proposed fuzzy logic algorithm, presents a novel technique for detecting and classifying faults in solar PV systems. Furthermore, the proposed method introduces fault indexing as a performance indicator that measures the degree of deviation from the normal operating conditions of the photovoltaic system. Various signatures of each fault scenario are identified in the shape of corresponding current-voltage trajectories and their extracted parameters. The effectiveness of the proposed technique is evaluated both in simulation and experimentally using a 5 kW grid connected solar array. It is demonstrated that the proposed technique is capable of diagnosing the occurrence of different faults with more than 98% accuracy.

3 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
MAMatiullah Ahsan
Matiullah Ahsan
NBNor Ramdon Bin Baharom
Nor Ramdon Bin Baharom
ZZZainab Zainal
Zainab Zainal
LMLuqman Hakim Mahmod
Luqman Hakim Mahmod
IUIrshad Ullah
Irshad Ullah
Rahisham Abd RahmanRahisham Abd Rahman
Rahisham Abd Rahman
High-voltage transmission technology has advanced quickly with the overall development and increased use of renewable energy. More demands on the insulating system are made when high-voltage power systems evolve. One of the significant factors is the sharp rise in population density, which led to the high demand for electricity. Right-of-way infringement is a problem that frequently occurs these days. Transmission is done over a rated capacity; as a result, the transmission line heats up, the insulation ages, and the electric field becomes distorted. The insulating system is prone to fail too soon when the operating voltage inverses or when there is a significant temperature differential. Environmentally friendly insulating materials have received much attention recently. A synergistic optimisation of heat resistance properties, mechanical properties, and dielectric properties must be accomplished before these materials can be used in high-voltage transmission systems. They must also withstand harsh electrical and thermal shocks such as overvoltage and short-circuit faults. One of the developments that has become a popular research topic is the constantly evolving tower design. This review article presents advancements in cross-arm technology in high-voltage transmission systems to elaborate on the limitations and contributions of different research work.

28 April 2024 in e-Prime - Advances in Electrical Engineering, Electronics and Energy
Verified
Journal Article
Open access
MAMatiullah Ahsan
Matiullah Ahsan
NBNor Ramdon bin Baharom
Nor Ramdon bin Baharom
ZZZainab Binti Zainal
Zainab Binti Zainal
IKIhsan Ullah Khalil
Ihsan Ullah Khalil

24 July 2025 in Measurement
Verified
Journal Article
Closed access
UKUmais Khan
Umais Khan
SKSarim Farqaleet Khan
Sarim Farqaleet Khan
IKIhsan Ullah Khalil
Ihsan Ullah Khalil
MAMatiullah Ahsan
Matiullah Ahsan