The part of effective stress resulting from soil moisture or soil suction variation can be defined by the suction stress characteristic curve (SSCC). For a given soil, the SSCC can be experimentally determined from shear-strength tests. Recent work shows that the SSCC can be uniquely linked to the soil-water characteristic curve (SWCC). The uniqueness of the SSCC determined from both shear strength and soil moisture retention tests is examined for several residual soils in Korea. The validity of the effective stress principle is demonstrated by showing that effective stress-based on the SSCC describes the same unique failure criterion as that for the saturated failure criterion. The measured SSCCs are also shown to predict the soil-water retention curves within a few percentage. The SWCCs of these residual soils, determined directly from soil moisture retention tests, also accord well with the SSCCs determined directly from triaxial shear-strength tests with the difference within several tens of kPa. Ther...
The primary objectives of this study are to investigate the interference of ground penetrating radar (GPR) signals with air-cavities behind concrete linings subjected to three experimental parameters (GPR antenna frequency, thickness of concrete lining, and thickness of air-cavities), and their effects on the evaluation of important engineering parameters (thickness of concrete, and length and thickness of air-cavities) for tunnel structure inspection using GPR. For these purposes, first, a concrete model specimen is fabricated in the laboratory, which simulates air-cavity defects with various thicknesses (0 mm, 30 mm, 100 mm, 200 mm, and 300 mm) behind concrete with four different thicknesses (100 mm, 200 mm, 300 mm, and 400 mm) in tunnel structures. Second, a series of GPR survey is performed on the fabricated concrete model specimen using three ground-coupled GPR antennas with nominal center frequencies of 400 MHz, 900 MHz, and 1600 MHz. Third, a practical signal interpretation method is proposed to evaluate air-cavities in concrete tunnel linings subjected to the three experimental parameters. It is demonstrated that the cross-correlation analysis is effective for identifying air-cavities behind concrete, and for characterizing the length of the air-cavities. In addition, the thicknesses of air-cavities are estimated by a new approach in this study, measuring the apparent time delay of partially overlapped electromagnetic wave reflections within air-cavities. The results in this study provide a fundamental basis to improve GPR signal interpretation techniques for the evaluation of air-cavities behind concrete tunnel linings.
Multi-channel Impact-echo (IE) testing was used to evaluate debonding defects at the interface between track concrete layer, TCL, and hydraulically stabilized base course, HSB, in a real scale mockup model of concrete slab tracks for Korea high-speed railway (KHSR) system. The mockup model includes three debonding defects that were fabricated by inserting three 400 mm by 400 mm (length and width) thin plastic foam boards with three different thicknesses of 5 mm, 10 mm, and 15 mm, before casting concrete in TCL. Multi-channel IE signals obtained over solid concrete and debonding defects were reduced to three critical IE testing parameters (the velocity of concrete, peak frequency, and Q factor). Bilinear classification models were used to evaluate the individual and a combination of the characteristic parameters. It was demonstrated that the best evaluation performance was obtained by using average peak frequency or the combination of average peak frequency and average Q factor, obtained by eight accelerometers in the multi-channel IE device. The results and discussion in this study would improve the understanding of characteristics of multiple IE testing parameters in concrete slab tracks and provide a fundamental basis to develop an effective prediction model of non-destructive evaluation for debonding defects at the interface between TCL and HSB in concrete slab tracks.
The condition of the ballast is a critical factor affecting the riding quality and the performance of a track. Fouled ballast can accelerate track irregularities, which results in frequent ballast maintenance requirements. Severe fouling of the ballast can lead to track instability, an uncomfortable ride and, in the worst case, a derailment. In this regard, maintenance engineers perform routine track inspections to assess current and future ballast conditions. GPR has been used to assess the thickness and fouling levels of ballast. However, there are no potent procedures or specifications with which to determine the level of fouling. This research aims to develop a GPR analysis method capable of evaluating ballast fouling levels. Four ballast boxes were constructed with various levels of fouling. GPR testing was conducted using a GSSI (Geophysical Survey Systems, Inc.) device (400, 900, 1600 MHz), and a KRRI (Korea Railroad Research Institute) GPR device (500 MHz), which was developed for ballast tracks. The dielectric permittivity, scattering of the depth (thickness) values, signal strength at the ballast boundary, and area of the frequency spectrum were compared against the fouling level. The results show that as the fouling level increases, the former two variables increase while the latter two decrease. On the basis of these observations, a new integrated parameter, called a ballast condition scoring index (BCSI), is suggested. The BCSI was verified using field data. The results show that the BCSI has a strong correlation with the fouling level of the ballast and can be used as a fouling-level-indicating parameter.