Laurent Francis

Prof. Laurent Francis

Institute for Information and Communication Technologies, Electronics and Applied Mathematics (ICTEAM), Université catholique de Louvain (UCL), Louvain-la-Neuve, Belgium
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Atmospheric Environment
Verified
Journal Article
Open access
CBC. Borrego
C. Borrego
ACA.M. Costa
A.M. Costa
JGJ. Ginja
J. Ginja
Marlene AmorimMarlene Amorim
Marlene Amorim
MCM. Coutinho
M. Coutinho
Michele PenzaMichele Penza
Michele Penza
The 1st EuNetAir Air Quality Joint Intercomparison Exercise organized in Aveiro (Portugal) from 13th–27th October 2014, focused on the evaluation and assessment of environmental gas, particulate matter (PM) and meteorological microsensors, versus standard air quality reference methods through an experimental urban air quality monitoring campaign. The IDAD-Institute of Environment and Development Air Quality Mobile Laboratory was placed at an urban traffic location in the city centre of Aveiro to conduct continuous measurements with standard equipment and reference analysers for CO, NOx, O3, SO2, PM10, PM2.5, temperature, humidity, wind speed and direction, solar radiation and precipitation.The comparison of the sensor data generated by different microsensor-systems installed side-by-side with reference analysers, contributes to the assessment of the performance and the accuracy of microsensor-systems in a real-world context, and supports their calibration and further development.The overall performance of the sensors in terms of their statistical metrics and measurement profile indicates significant differences in the results depending on the platform and on the sensors considered. In terms of pollutants, some promising results were observed for O3 (r2: 0.12–0.77), CO (r2: 0.53–0.87), and NO2 (r2: 0.02–0.89). For PM (r2: 0.07–0.36) and SO2 (r2: 0.09–0.20) the results show a poor performance with low correlation coefficients between the reference and microsensor measurements. These field observations under specific environmental conditions suggest that the relevant microsensor platforms, if supported by the proper post processing and data modelling tools, have enormous potential for new strategies in air quality control

1 September 2005 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
LHLieven Huang
Lieven Huang
GRGunter Reekmans
Gunter Reekmans
DSDirk Saerens
Dirk Saerens
JFJean-Michel Friedt
Jean-Michel Friedt
FFFilip Frederix
Filip Frederix
CHChris Van Hoof
Chris Van Hoof

8 June 2004 in Langmuir
Verified
Journal Article
Closed access
CZCheng Zhou
Cheng Zhou
JFJean-Michel Friedt
Jean-Michel Friedt
Angelina AngelovaAngelina Angelova
Angelina Angelova
KCKang-Hoon Choi
Kang-Hoon Choi
WLWim Laureyn
Wim Laureyn
GBGustaaf Borghs
Gustaaf Borghs

13 May 2015 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
NCNuma Couniot
Numa Couniot
Laurent FrancisLaurent Francis
Laurent Francis
Denis FlandreDenis Flandre
Denis Flandre
We present a 16 × 16 CMOS biosensor array aiming at impedance detection of whole-cell bacteria. Each 14 μm×16 μm pixel comprises high-sensitive passivated microelectrodes connected to an innovative readout interface based on charge sharing principle for capacitance-to-voltage conversion and subthreshold gain stage to boost the sensitivity. Fabricated in a 0.25 μm CMOS process, the capacitive array was experimentally shown to perform accurate dielectric measurements of the electrolyte up to electrical conductivities of 0.05 S/m, with maximal sensitivity of 55 mV/fF and signal-to-noise ratio (SNR) of 37 dB. As biosensing proof of concept, real-time detection of Staphylococcus epidermidis binding events was experimentally demonstrated and provides detection limit of ca. 7 bacteria per pixel and sensitivity of 2.18 mV per bacterial cell. Models and simulations show good matching with experimental results and provide a comprehensive analysis of the sensor and circuit system. Advantages, challenges and limits of the proposed capacitive biosensor array are finally described with regards to literature. With its small area and low power consumption, the present capacitive array is particularly suitable for portable point-of-care (PoC) diagnosis tools and lab-on-chip (LoC) systems.

1 November 2017 in Solar Energy
Verified
Journal Article
Open access
RKR. Kotipalli
R. Kotipalli
OPO. Poncelet
O. Poncelet
GLG. Li
G. Li
YZY. Zeng
Y. Zeng
Laurent FrancisLaurent Francis
Laurent Francis
Denis FlandreDenis Flandre
Denis Flandre
We present a (1-D) SCAPS device model to address the following: (i) the surface passivation mechanisms (i.e. field-effect and chemical), (ii) their impact on the CIGS solar cell performance for varying CIGS absorber thickness, (iii) the importance of fixed charge type (+/−) and densities of fixed and interface trap charges, and (iv) the reasons for discrete gains in the experimental cell efficiencies (previously reported) for varying CIGS absorber thickness. First, to obtain a reliable device model, the proposed set of parameters is validated for both field-effect (due to fixed charges) and chemical passivation (due to interface traps) using a simple M-I-S test structure and experimentally extracted values (previously reported) into the SCAPS simulator. Next, we provide figures of merits without any significant loss in the solar cell performances for minimum net −Qf and maximum acceptable limit for Dit, found to be ∼5 × 1012 cm−2 and ∼1 × 1013 cm−2 eV−1 respectively. We next show that the influence of negative fixed charges in the rear passivation layer (i.e. field-effect passivation) is more predominant than that of the positive fixed charges (i.e. counter-field effect) especially while considering ultra-thin (<0.5 μm) absorber layers. Furthermore, we show the importance of rear reflectance on the short-circuit photocurrent densities while scaling down the CIGS absorber layers below 0.5 μm under interface chemical and field-effect passivation mechanisms. Finally, we provide the optimal rear passivation layer parameters for efficiencies greater than 20% with ultra-thin CIGS absorber thickness (<0.5 μm). Based on these simulation results, we confirm that a negatively charged rear surface passivation with nano-point contact approach is efficient for the enhancement of cell performances, especially while scaling down the absorber thickness below 0.5 μm.

1 December 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
NCN. Couniot
N. Couniot
Denis FlandreDenis Flandre
Denis Flandre
Laurent FrancisLaurent Francis
Laurent Francis
AAA. Afzalian
A. Afzalian