Juan Ruan

Mr. Juan Ruan


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2017 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
JRJuan Ruan
Juan Ruan
LHLirui Hu
Lirui Hu
ALAn Shan Lu
An Shan Lu
WLWei Yan Lu
Wei Yan Lu
JZJianfeng Zhu
Jianfeng Zhu
HXHongwei Xu
Hongwei Xu
A cost-efficient all fiber temperature sensor based on a Sagnac interferometer (SI) is proposed and experimentally demonstrated. The sensor proposed comprises a section of thin core fiber (TCF) in combination with Panda type polarization maintaining fiber (PMF). The key point is that the core of TCF is intentionally aligned to one of two stress areas of Panda type PMF in order to change the mode transmission. Then the prepared TCF-PMF fiber structure is built into a Sagnac loop. A well-defined spectrum is obtained and the fringe contrast reaches up to 28dB. The dip wavelengths are employed to demonstrate the temperature characteristics. The experimental results show the transmission spectrum blue-shift with temperature and the sensitivity of −1.54 nm/° C is obtained. The proposed sensor has potential application in temperature measurement.

4 June 2020 in Microwave and Optical Technology Letters
Verified
Journal Article
Closed access
PDF file
JRJuan Ruan
Juan Ruan

26 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCjianjun chen
jianjun chen
JWJiang Wang
Jiang Wang
NWNing Wang
Ning Wang
JRJuan Ruan
Juan Ruan
JZJie Zhang
Jie Zhang
YZYong Zhu
Yong Zhu
An improved acoustic pick-up is presented to enhance the acoustic sensing sensitivity of the straight line-type Sagnac fiber optic acoustic sensing system. A hollow elastomer cylinder is introduced into the system, and the optical fiber is tightly wound around the cylinder to construct the pick-up. The theoretical analysis was finished, and it showed that the improved pick-up will bring in an extra phase change and let the phase difference increase almost an order. The extra phase change will enhance the sensing sensitivity correspondingly. The titanium alloy elastic cylinder was designed and manufactured. The experiment system was built, and a sinusoidal acoustic signal was used as the sound source. The tests were taken during 100–1500 Hz, and the experimental study showed that the sensitivity was more than 130 mV/Pa when the pick-up was used as the acoustic sensing element, and compared to the fiber only system, the sensitivity was enhanced more than 71.2%. The improved pick-up will be helpful in sound recognition and expand the application area of the Sagnac acoustic sensing system.

1 December 2023 in ECS Journal of Solid State Science and Technology
Verified
Journal Article
Closed access
PDF file
HLHaiPing Li
HaiPing Li
JRJuan Ruan
Juan Ruan
XLXin Li
Xin Li
ZYZiQin Yang
ZiQin Yang
ZXZhangLiang Xu
ZhangLiang Xu
YLYang Luo
Yang Luo
A surface plasmon resonance photonic crystal fiber-based highly sensitive temperature sensor is proposed. The surface plasmon resonance is induced by injecting toluene into the central hole and ethanol into the side holes coated with gold film. Optimal sensor sensitivity by optimizing the size and position of the air holes. The coupling mechanism and sensing performance of the proposed sensor are analyzed. The results indicate that in the sensing range of 0 °C−70 °C, the highest figure of merit (FOM) is 0.1169/°C and the average temperature sensitivity can reach 7.13 nm/°C. Such temperature sensor exhibits tremendous potential in the domain of temperature detection.

19 January 2021 in IET Optoelectronics
Verified
Journal Article
Open access
PDF file
JRJuan Ruan
Juan Ruan
A high sensitivity, simple fabrication all‐fibre strain sensor is proposed and demonstrated experimentally. The sensor consists of a section of Panda‐type polarization maintaining fibre (PMF) built into a Sagnac interferometer. The Panda‐type PMF is intentionally spliced to the single‐mode fibre through enhanced fusion splicing to excite high‐order polarized modes. The enhanced fusion splicing characterizes a large magnitude of overlap. The measured strain sensitivity reaches up to 32 pm/με and the strain resolution of 0.63 με has been achieved. The proposed fibre strain sensor characterizing easy fabrication and high sensitivity can be a good candidate in the field of structural health monitoring.

11 January 2023 in Photonics
Verified
Journal Article
Open access
PDF file
JWJiang Wang
Jiang Wang
RTRuixi Tang
Ruixi Tang
JCjianjun chen
jianjun chen
NWNing Wang
Ning Wang
YZYong Zhu
Yong Zhu
JRJuan Ruan
Juan Ruan
A straight-line-type Sagnac optic fiber acoustic sensing system is proposed in this paper to adopt the application needs of no man’s plateau borderline for monitoring mechanical invasion. The Sagnac interference fiber loop is replaced by a straight-line fiber and a 1 × 2 coupler, and the length of the Sagnac interference fiber loop is shortened by close to 50%. The influences of delay fiber and sensing fiber on the sensing system are analyzed by theory calculation and simulation and the optimal lengths of delay fiber and sensing fiber were decided. The experiment system was set, and the sensing fiber was wound into titanium alloy cylinder to compose the sensing element. Experimental results show that the sensing system has a good response to 50−8000 Hz and 70 dB sinusoidal acoustical signals and can well distinguish the signals of different frequencies. Using a small-scale helicopter audio signal as the acoustical signal, the test results show that the response curve is consistent with the simulation results and the sensitivity reaches 30.67 mV/Pa.