Eleonora Favuzza

Dr. Eleonora Favuzza

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2018 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
RMRita Mencucci
Rita Mencucci
EFEleonora Favuzza
Eleonora Favuzza
OCOrsola Caporossi
Orsola Caporossi
ASAlfonso Savastano
Alfonso Savastano
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo

1 August 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RMRita Mencucci
Rita Mencucci
CBCarlotta Boccalini
Carlotta Boccalini
RCRoberto Caputo
Roberto Caputo
EFEleonora Favuzza
Eleonora Favuzza
To evaluate the efficacy and safety of using sodium hyaluronate 0.1% and carboxymethylcellulose 0.5% artificial tears for ocular discomfort and tear-film stability in eyes after cataract surgery. Twenty ophthalmic centers in Italy. Prospective randomized case series. This study enrolled patients scheduled for unilateral cataract surgery. After surgery, patients received artificial tears and a topical steroid-antibiotic (study group) or topical steroid-antibiotic alone (control group) and were assessed postoperatively at 1 and 5 weeks. Outcome measures were tear breakup time (TBUT), ocular surface disease index (OSDI), frequency of dry-eye symptoms evaluated using a visual analog scale (VAS), and corneal fluorescein staining. The study comprised 282 patients. At 5 weeks, the mean TBUT was statistically significantly higher in the study group than in the control group (P = .0003). The mean OSDI score statistically significantly improved in both groups from 1 to 5 weeks (P < .0001 for both groups); however, there was no statistically significant difference between the groups at these timepoints. The artificial tears statistically significantly improved VAS-assessed dry-eye symptoms in the study group compared with the control group at 5 weeks (P < .001). The mean corneal fluorescein staining was significantly reduced in the study group compared with the control group at 5 weeks (P = .002 versus P = .05, respectively). No treatment-related adverse events were reported. Sodium hyaluronate 0.1% and carboxymethylcellulose 0.5% ophthalmic solution was effective and well tolerated in reducing dry-eye disease symptoms and improving the clinical outcome after cataract surgery. No author has a financial or proprietary interest in any material or method mentioned.

Verified
Journal Article
Open access
PDF file
RMRita Mencucci
Rita Mencucci
AMAlberto Morelli
Alberto Morelli
MCMichela Cennamo
Michela Cennamo
ARAnna Maria Roszkowska
Anna Maria Roszkowska
EFEleonora Favuzza
Eleonora Favuzza
The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cataract surgery with bilateral implantation of Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc., Jacksonville, FL, USA), Vivinex Impress XY1-EM (Hoya Surgical Optics, Singapore) or IsoPure 123 (PhysIOL, Liege, Belgium) IOLs. Three months postoperatively, monocular and binocular uncorrected and corrected distant, and intermediate and near visual acuities were measured. Binocular defocus curve, photopic contrast sensitivity, Point Spread Function (PSF), low order aberrations (LOAs), high order aberrations (HOAs), objective scatter index (OSI), halo and glare perception were also evaluated. This study included a total of 72 eyes from 36 patients. Visual acuity outcomes, PSF, LOAs, HOAs and OSI were similar between groups. There were no statistically significant differences in terms of photopic contrast sensitivity, halo or glare perception. In patients without ocular comorbidities, the Eyhance ICB00 IOL, the Vivinex Impress IOL and the Isopure IOL—even though based on different optical properties—provided similar results in terms of visual acuity, contrast sensitivity and intraocular aberrations, with no influence on photic phenomena.

17 July 2017 in Journal of Cellular and Molecular Medicine
Verified
Journal Article
Open access
PDF file
MMMirca Marini
Mirca Marini
RMRita Mencucci
Rita Mencucci
Irene RosaIrene Rosa
Irene Rosa
EFEleonora Favuzza
Eleonora Favuzza
DGDaniele Guasti
Daniele Guasti
Mirko ManettiMirko Manetti
Mirko Manetti
Telocytes (TC) are typically defined as cells with telopodes by their ultrastructural features. Their presence was reported in the interstitium of various organs in vertebrates, including humans. However, no study has yet described the presence of TC in the human eye and in particular, within the stromal compartment of the cornea. To address this issue, samples of normal and pathologic (keratoconic) human corneas were tested by immunohistochemistry for CD34, platelet‐derived growth factor receptor α (PDGFRα) and c‐kit/CD117 or examined by transmission electron microscopy. We found that TC coexpressing CD34 and PDGFRα were distributed throughout the whole normal corneal stroma with different TC subtypes being distinguishable on the basis of the expression of the stemness marker c‐kit (i.e. c‐kit‐positive and c‐kit‐negative TC subpopulations). Transmission electron microscopy examination confirmed the existence of spindle‐shaped and bipolar TC typically displaying two long and thin moniliform telopodes establishing intercellular contacts formed by gap junctions. Keratoconic corneas were characterized by ultrastructural damages and patchy loss of TC with an almost complete depletion of the c‐kit‐positive TC subpopulation. We propose that TC may contribute to the maintenance of corneal stromal homoeostasis and that, in particular, the c‐kit‐positive TC subtype might have stemness capacity participating in corneal regeneration and repair processes. Further studies are needed to clarify the differential roles of corneal TC subtypes as well as the possible therapeutic applications of TC in degenerative corneal disorders such as keratoconus.

2 September 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
PVPaolo Vinciguerra
Paolo Vinciguerra
RMRita Mencucci
Rita Mencucci
Vito RomanoVito Romano
Vito Romano
ESEberhard Spoerl
Eberhard Spoerl
FCFabrizio I. Camesasca
Fabrizio I. Camesasca
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
Purpose.To compare biomechanical effect, riboflavin penetration and distribution in transepithelial corneal collagen cross-linking with iontophoresis (I-CXL), with standard cross linking (S-CXL) and current transepithelial protocol (TE-CXL).Materials and Methods.The study was divided into two different sections, considering, respectively, rabbit and human cadaver corneas. In both sections corneas were divided according to imbibition protocols and irradiation power. Imaging mass spectrometry by matrix-assisted laser desorption/ionization (MALDI-IMS) and stress-strain measurements were used. Forty-eight rabbit and twelve human cadaver corneas were evaluated.Results.MALDI-IMS showed a deep riboflavin penetration throughout the corneal layers with I-CXL, with a roughly lower concentration in the deepest layers when compared to S-CXL, whereas with TE-CXL penetration was considerably less. In rabbits, there was a significant increase (by 71.9% andP=0.05) in corneal rigidity after I-CXL, when compared to controls. In humans, corneal rigidity increase was not significantly different among the subgroups.Conclusions.In rabbits, I-CXL induced a significant increase in corneal stiffness as well as better riboflavin penetration when compared to controls and TE-CXL but not to S-CXL. Stress-strain in human corneas did not show significant differences among techniques, possibly because of the small sample size of groups. In conclusion, I-CXL could be a valid alternative to S-CXL for riboflavin delivery in CXL, preserving the epithelium.

6 March 2013 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
RMRita Mencucci
Rita Mencucci
CGCristina Giordano
Cristina Giordano
EFEleonora Favuzza
Eleonora Favuzza
JGJean-Jacques Gicquel
Jean-Jacques Gicquel
LSLeopoldo Spadea
Leopoldo Spadea
UMUgo Menchini
Ugo Menchini
Background/aim To evaluate wavefront aberrations and subjective quality of life after toric intraocular lens (TIOL) implantation. Methods Three groups of subjects who underwent unilateral cataract surgery with intraocular lens (IOL) implantation were compared: (1) toric group (n=40): corneal astigmatism >1.50 D, implanted with Acrysof toric SN60TT IOL (Alcon Inc, Fort Worth, Texas, USA); (2) astigmatic SN60AT group (n=40): corneal astigmatism >1.50 D, implanted with Acrysof SN60AT IOL; and (3) control group (n=40): corneal astigmatism <1.00 D, implanted with Acrysof SN60AT IOL. Uncorrected distance visual acuity (UDVA), refraction, lower order astigmatism (Z22, Z−22), Strehl ratio and the modulation transfer function area ratio were evaluated over a 3 month follow-up period. A standardised quality of life test (National Eye Institute Refractive Error Quality of Life Instrument-42) was distributed to both astigmatic groups 3 months postoperatively. Results Postoperative UDVA and aberrometric values were significantly better (p<0.001) and mean postoperative spherical equivalent was significantly lower (p<0.05) in the toric and control groups compared with the astigmatic SN60AT group. The toric group had significantly better postoperative quality of life compared with the astigmatic SN60AT group (p<0.05). Conclusions Acrysof TIOL implantation resulted in better visual, refractive and aberrometric results than SN60AT spherical IOL implantation in astigmatic patients, similar to the control group. The better objective optical and retinal image quality resulted in better subjective quality of life after TIOL implantation.