Hamza Benchakroun

Mr. Hamza Benchakroun

University of Galway, Galway, Ireland
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017
Verified
Conference Paper
Closed access
ZMZakaria Mahlaoui
Zakaria Mahlaoui
EAEva Antonino-Daviu
Eva Antonino-Daviu
MBMiguel Ferrando Bataller
Miguel Ferrando Bataller
HBHamza Benchakroun
Hamza Benchakroun
ALAdnane Latif
Adnane Latif

13 December 2021 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Open access
NINiko Ištuk
Niko Ištuk
AGAlessandra La Gioia
Alessandra La Gioia
HBHamza Benchakroun
Hamza Benchakroun
ALAoife J Lowery
Aoife J Lowery
BMBarry McDermott
Barry McDermott
MOMartin Ohalloran
Martin Ohalloran
Achieving a better characterization of human blood conductivity is of high relevance for medical applications. In this study we measured the complex impedance of N = 10 human whole blood samples (from N = 10 oncology patients) at room temperature ( T = 22.6 $\pm\; 0.8\;^\circ \mathrm{C}$ ) and at body temperature ( T = 36.6 $\pm\; 0.4\;^\circ \mathrm{C}$ ). The complex impedance was measured using the measurement setup consisting of a custom made four-electrode probe and a commercially available galvanostat. The measured complex impedance data were used to calculate the conductivity of whole blood over the 631 Hz–100 kHz frequency range. The calculated conductivity data is presented and was compared with the literature data. The data from our study is in good agreement with the data available in the literature. Additionally, full blood counts were provided for N = 8 samples and Pearson correlation coefficient was calculated between the conductivity and blood counts at different frequencies. The three blood count parameters with the highest correlation coefficient are haematocrit (Hct), haemoglobin (Hgb) and red cell count (RBC). The correlation coefficient was shown to decrease as the frequency increases and was the highest at f = 631 Hz, which is the lowest reported frequency. To our knowledge this is the first study to measure low-frequency (i.e. below 1 MHz) conductivity of whole human blood at body temperature using the four-electrode technique. The results of this study represent an important contribution to the literature, which is currently limited in this area and will help further medical device design.

1 January 2018
Verified
Conference Paper
Closed access
HBHamza Benchakroun
Hamza Benchakroun
MCM. Cabedo-Fabrés
M. Cabedo-Fabrés
MFM. Ferrando-Bataller
M. Ferrando-Bataller
ZMZ. Mahlaoui
Z. Mahlaoui
ALA. Latif
A. Latif
Inspec keywords: microstrip antennas; ultra wideband communication; ultra wideband antennas; body area networks; impedance matching; monopole antennas; antenna radiation patterns Subjects: Single antennas; Biomedical communication; Radio links and equipment

21 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HBHamza Benchakroun
Hamza Benchakroun
NINiko Ištuk
Niko Ištuk
EDEoghan Dunne
Eoghan Dunne
AEAdnan Elahi
Adnan Elahi
TOTony O'Halloran
Tony O'Halloran
Declan O'LoughlinDeclan O'Loughlin
Declan O'Loughlin
The electrical properties of many biological tissues are freely available from the INRC and the IT’IS databases. However, particularly in lower frequency ranges, few studies have investigated the optimal measurement protocol or the key confounders that need to be controlled, monitored, and reported. However, preliminary work suggests that the contact force of the measurement probe on the tissue sample can affect the measurements. The aim of this paper is to investigate the conductivity change due to the probe contact force in detail. Twenty ex vivo bovine heart samples are used, and conductivity measurements are taken in the Left Atrial Appendage, a common target for medical device developments. The conductivity measurements reported in this work (between 0.14 S/m and 0.24 S/m) align with the literature. The average conductivity is observed to change by −21% as the contact force increases from 2 N to 10 N. In contrast, in conditions where the fluid concentration in the measurement area is expected to be lower, very small changes are observed (less than 2.5%). These results suggest that the LAA conductivity is affected by the contact force due to the fluid concentration in the tissue. This work suggests that contact force should be controlled for in all future experiments.

8 November 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HBHamza Benchakroun
Hamza Benchakroun
NINiko Ištuk
Niko Ištuk
EDEoghan Dunne
Eoghan Dunne
AEAdnan Elahi
Adnan Elahi
TOTony O'HAlloran
Tony O'HAlloran
DODeclan O'LOughlin
Declan O'LOughlin
Recently, non-thermal pulsed-field-ablation using electroporation has generated a lot of interest as a potential treatment for Atrial Fibrillation. The electrical properties, and specially the conductivity of cardiac tissues, are used in the in treatment planning of non-thermal pulsed field ablation. However, there is no standard approach to measure the conductivity, particularly for the left atrial appendage (LAA). Electrical conductivity characterization studies, focusing on cardiac tissues, have used different probe typologies with different electrodes sizes. Furthermore, no study has investigated the effect of the probe design on the acquired conductivity. In this study, common leading probe typologies with different electrode size are compared in terms of accuracy and measurement repeatability. Using liquid phantoms, differences in term of measurement accuracy and repeatability are observed between the probe designs which suggests that the measurement probe design influences the data acquisition quality. Based on these results, a custom probe design is proposed suitable for the characterization of the conductivity of the LAA. The probe is tested using ten ex vivo bovine tissue samples between 0.1 Hz and 100 kHz. The mean conductivity of the LAA acquired from the ten samples is 2.5 mS/cm with a standard deviation of 0.24 mS/cm which is in line with conductivity of cardiac tissues in the literature. The conductivity values of the left atrial appendage may be useful in electroporation treatment planning, furthermore this study suggests that adapting the probe design to the tissue under study can be important.

19 February 2026 in Journal of Thermoplastic Composite Materials
Verified
Journal Article
Open access
HBHamza Benchakroun
Hamza Benchakroun
MFMichael Flanagan
Michael Flanagan
BBBogdan Baturov
Bogdan Baturov
NHNoel M Harrison
Noel M Harrison
MDMaeve Duffy
Maeve Duffy
Carbon fibre steering offers a pathway to designing composite susceptors that could replace metallic inserts in the induction welding of carbon fibre–reinforced polymer laminates. By tailoring the fibre architecture, the composite itself can act as an integrated susceptor capable of controlled electromagnetic heating. A finite element model is developed in COMSOL Multiphysics to predict temperature evolution and current concentration within such tailored laminates. The model is first validated using unidirectional samples with fibre orientations of 0°, 90°, +45°, and −45°, and subsequently extended to complex susceptor configurations, including circular, concentric, and quasi-isotropic designs. The simulation explicitly accounts for local mesostructural effects to capture anisotropic conduction and edge effects governing heat distribution. Results indicate that the concentric configuration achieves the highest peak temperatures with strongly localised heating; the circular pattern yields radially symmetric temperature fields, and the quasi-isotropic layup provides uniform but less intense heating. Experimental infrared thermography confirms these trends, showing good agreement with model predictions. The work demonstrates that susceptor geometry can be engineered through fibre steering to control induction heating behavior, providing a lightweight, corrosion-free, and sustainable alternative to metallic inserts for joining and repair of thermoplastic composites in aerospace and automotive applications.