Niko Ištuk

Mr. Niko Ištuk

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
EKEugenijus Kaniusas
Eugenijus Kaniusas
SKStefan Kampusch
Stefan Kampusch
MTMarc Tittgemeyer
Marc Tittgemeyer
FPFivos Panetsos
Fivos Panetsos
RGRaquel Fernandez Gines
Raquel Fernandez Gines
JSJozsef Constantin Széles
Jozsef Constantin Széles
Electrical stimulation of the auricular vagus nerve (aVNS) is an emerging technology in the field of bioelectronic medicine with applications in therapy. Modulation of the afferent vagus nerve affects a large number of physiological processes and bodily states associated with information transfer between the brain and body. These include disease mitigating effects and sustainable therapeutic applications ranging from chronic pain diseases, neurodegenerative and metabolic ailments to inflammatory and cardiovascular diseases. Given the current evidence from experimental research in animal and clinical studies we discuss basic aVNS mechanisms and their potential clinical effects. Collectively, we provide a focused review on the physiological role of the vagus nerve and formulate a biology-driven rationale for aVNS. For the first time, two international workshops on aVNS have been held in Warsaw and Vienna in 2017 within the framework of EU COST Action "European network for innovative uses of EMFs in biomedical applications (BM1309)." Both workshops focused critically on the driving physiological mechanisms of aVNS, its experimental and clinical studies in animals and humans, in silico aVNS studies, technological advancements, and regulatory barriers. The results of the workshops are covered in two reviews, covering physiological and engineering aspects. The present review summarizes on physiological aspects - a discussion of engineering aspects is provided by our accompanying article (Kaniusas et al., 2019). Both reviews build a reasonable bridge from the rationale of aVNS as a therapeutic tool to current research lines, all of them being highly relevant for the promising aVNS technology to reach the patient.

24 July 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
EKEugenijus Kaniusas
Eugenijus Kaniusas
SKStefan Kampusch
Stefan Kampusch
MTMarc Tittgemeyer
Marc Tittgemeyer
FPFivos Panetsos
Fivos Panetsos
RGRaquel Fernandez Gines
Raquel Fernandez Gines
ASAntonio Sarolic
Antonio Sarolic
Electrical stimulation of the auricular vagus nerve (aVNS) is an emerging electroceutical technology in the field of bioelectronic medicine with applications in therapy. Artificial modulation of the afferent vagus nerve – a powerful entrance to the brain – affects a large number of physiological processes implicating interactions between the brain and body. Engineering aspects of aVNS determine its efficiency in application. The relevant safety and regulatory issues need to be appropriately addressed. In particular, in silico modeling acts as a tool for aVNS optimization. The evolution of personalized electroceuticals using novel architectures of the closed-loop aVNS paradigms with biofeedback can be expected to optimally meet therapy needs. For the first time, two international workshops on aVNS have been held in Warsaw and Vienna in 2017 within the scope of EU COST Action “European network for innovative uses of EMFs in biomedical applications (BM1309).” Both workshops focused critically on the driving physiological mechanisms of aVNS, its experimental and clinical studies in animals and humans, in silico aVNS studies, technological advancements, and regulatory barriers. The results of the workshops are covered in two reviews, covering physiological and engineering aspects. The present review summarizes on engineering aspects – a discussion of physiological aspects is provided by our accompanying article (Kaniusas et al., 2019). Both reviews build a reasonable bridge from the rationale of aVNS as a therapeutic tool to current research lines, all of them being highly relevant for the promising aVNS technology to reach the patient.

13 December 2021 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Open access
NINiko Ištuk
Niko Ištuk
AGAlessandra La Gioia
Alessandra La Gioia
HBHamza Benchakroun
Hamza Benchakroun
ALAoife J Lowery
Aoife J Lowery
BMBarry McDermott
Barry McDermott
MOMartin Ohalloran
Martin Ohalloran
Achieving a better characterization of human blood conductivity is of high relevance for medical applications. In this study we measured the complex impedance of N = 10 human whole blood samples (from N = 10 oncology patients) at room temperature ( T = 22.6 $\pm\; 0.8\;^\circ \mathrm{C}$ ) and at body temperature ( T = 36.6 $\pm\; 0.4\;^\circ \mathrm{C}$ ). The complex impedance was measured using the measurement setup consisting of a custom made four-electrode probe and a commercially available galvanostat. The measured complex impedance data were used to calculate the conductivity of whole blood over the 631 Hz–100 kHz frequency range. The calculated conductivity data is presented and was compared with the literature data. The data from our study is in good agreement with the data available in the literature. Additionally, full blood counts were provided for N = 8 samples and Pearson correlation coefficient was calculated between the conductivity and blood counts at different frequencies. The three blood count parameters with the highest correlation coefficient are haematocrit (Hct), haemoglobin (Hgb) and red cell count (RBC). The correlation coefficient was shown to decrease as the frequency increases and was the highest at f = 631 Hz, which is the lowest reported frequency. To our knowledge this is the first study to measure low-frequency (i.e. below 1 MHz) conductivity of whole human blood at body temperature using the four-electrode technique. The results of this study represent an important contribution to the literature, which is currently limited in this area and will help further medical device design.

16 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
NINiko Ištuk
Niko Ištuk
Emily PorterEmily Porter
Emily Porter
Declan O'LoughlinDeclan O'Loughlin
Declan O'Loughlin
BMBarry McDermott
Barry McDermott
ASAdam Santorelli
Adam Santorelli
MOMartin Ohalloran
Martin Ohalloran
Accurate knowledge of the dielectric properties of biological tissues is important in dosimetry studies and for medical diagnostic, monitoring and therapeutic technologies. In particular, the dielectric properties of the heart are used in numerical simulations of radiofrequency and microwave heart ablation. In one recent study, it was demonstrated that the dielectric properties of different components of the heart can vary considerably, contrary to previous literature that treated the heart as a homogeneous organ with measurements that ignored the anatomical location. Therefore, in this study, we record and report the dielectric properties of the heart as a heterogeneous organ. We measured the dielectric properties at different locations inside and outside of the heart over the 500 MHz to 20 GHz frequency range. Different parts of the heart were identified based on the anatomy of the heart and their function; they include the epicardium, endocardium, myocardium, exterior and interior surfaces of atrial appendage, and the luminal surface of the great vessels. The measured dielectric properties for each part of the heart are reported at both a single frequency (2.4 GHz), which is of interest in microwave medical applications, and as parameters of a broadband Debye model. The results show that in terms of dielectric properties, different parts of the heart should not be considered the same, with more than 25% difference in dielectric properties between some parts. The specific Debye models and single frequency dielectric properties from this study can be used to develop more detailed models of the heart to be used in electromagnetic modeling.

2 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
matteo savazzimatteo savazzi
matteo savazzi
SASoroush Abedi
Soroush Abedi
NINiko Ištuk
Niko Ištuk
NJNadine Joachimowicz
Nadine Joachimowicz
Helene et RousselHelene et Roussel
Helene et Roussel
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
We produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz–8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.

21 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HBHamza Benchakroun
Hamza Benchakroun
NINiko Ištuk
Niko Ištuk
EDEoghan Dunne
Eoghan Dunne
AEAdnan Elahi
Adnan Elahi
TOTony O'Halloran
Tony O'Halloran
Declan O'LoughlinDeclan O'Loughlin
Declan O'Loughlin
The electrical properties of many biological tissues are freely available from the INRC and the IT’IS databases. However, particularly in lower frequency ranges, few studies have investigated the optimal measurement protocol or the key confounders that need to be controlled, monitored, and reported. However, preliminary work suggests that the contact force of the measurement probe on the tissue sample can affect the measurements. The aim of this paper is to investigate the conductivity change due to the probe contact force in detail. Twenty ex vivo bovine heart samples are used, and conductivity measurements are taken in the Left Atrial Appendage, a common target for medical device developments. The conductivity measurements reported in this work (between 0.14 S/m and 0.24 S/m) align with the literature. The average conductivity is observed to change by −21% as the contact force increases from 2 N to 10 N. In contrast, in conditions where the fluid concentration in the measurement area is expected to be lower, very small changes are observed (less than 2.5%). These results suggest that the LAA conductivity is affected by the contact force due to the fluid concentration in the tissue. This work suggests that contact force should be controlled for in all future experiments.