Joost Geeroms

Dr. Joost Geeroms

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
HVHuong Vu
Huong Vu
DDDianbiao Dong
Dianbiao Dong
Hoang-Long CaoHoang-Long Cao
Hoang-Long Cao
TVTom Verstraten
Tom Verstraten
DLDirk Lefeber
Dirk Lefeber
JGJoost Geeroms
Joost Geeroms
Fast and accurate gait phase detection is essential to achieve effective powered lower-limb prostheses and exoskeletons. As the versatility but also the complexity of these robotic devices increases, the research on how to make gait detection algorithms more performant and their sensing devices smaller and more wearable gains interest. A functional gait detection algorithm will improve the precision, stability, and safety of prostheses, and other rehabilitation devices. In the past years the state-of-the-art has advanced significantly in terms of sensors, signal processing, and gait detection algorithms. In this review, we investigate studies and developments in the field of gait event detection methods, more precisely applied to prosthetic devices. We compared advantages and limitations between all the proposed methods and extracted the relevant questions and recommendations about gait detection methods for future developments.

2 December 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
SBSander De Bock
Sander De Bock
JGJo Ghillebert
Jo Ghillebert
RGRenee Govaerts
Renee Govaerts
SEShirley A. Elprama
Shirley A. Elprama
UMUros Marusic
Uros Marusic
KPKevin De Pauw
Kevin De Pauw
Shoulder exoskeletons potentially reduce overuse injuries in industrial settings including overhead work or lifting tasks. Previous studies evaluated these devices primarily in laboratory setting, but evidence of their effectiveness outside the lab is lacking. The present study aimed to evaluate the effectiveness of two passive shoulder exoskeletons and explore the transfer of laboratory-based results to the field. Four industrial workers performed controlled and in-field evaluations without and with two exoskeletons, ShoulderX and Skelex in a randomized order. The exoskeletons decreased upper trapezius activity (up to 46%) and heart rate in isolated tasks. In the field, the effects of both exoskeletons were less prominent (up to 26% upper trapezius activity reduction) while lifting windscreens weighing 13.1 and 17.0 kg. ShoulderX received high discomfort scores in the shoulder region and usability of both exoskeletons was moderate. Overall, both exoskeletons positively affected the isolated tasks, but in the field the support of both exoskeletons was limited. Skelex, which performed worse in the isolated tasks compared to ShoulderX, seemed to provide the most support during the in-field situations. Exoskeleton interface improvements are required to improve comfort and usability. Laboratory-based evaluations of exoskeletons should be interpreted with caution, since the effect of an exoskeleton is task specific and not all in-field situations with high-level lifting will equally benefit from the use of an exoskeleton. Before considering passive exoskeleton implementation, we recommend analyzing joint angles in the field, because the support is inherently dependent on these angles, and to perform in-field pilot tests. This paper is the first thorough evaluation of two shoulder exoskeletons in a controlled and in-field situation.

15 March 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
SBSander De Bock
Sander De Bock
MRMarco Rossini
Marco Rossini
DLDirk Lefeber
Dirk Lefeber
CGCarlos Rodriguez Guerrero
Carlos Rodriguez Guerrero
JGJoost Geeroms
Joost Geeroms
KPKevin De Pauw
Kevin De Pauw
Objective: This paper assesses the effect of a passive shoulder exoskeleton prototype, Exo4Work, on muscle activity, muscle fatigue and subjective experience during simulated occupational overhead and non-overhead work. Methods: Twenty-two healthy males performed six simulated industrial tasks with and without Exo4Work exoskeleton in a randomized counterbalanced cross-over design. During these tasks electromyography, heart rate, metabolic cost, subjective parameters and performance parameters were acquired. The effect of the exoskeleton and the body side on these parameters was investigated. Results: Anterior deltoid activity and fatigue reduced up to 16% and 41%, respectively, during isometric overhead work, and minimized hindrance of the device during non-overhead tasks. Wearing the exoskeleton increased feelings of frustration and increased discomfort in the areas where the exoskeleton and the body interfaced. The assistive effect of the exoskeleton was less prominent during dynamic tasks. Conclusion: This exoskeleton may reduce muscle activity and delay development of muscle fatigue in an overhead working scenario. For dynamic applications, the exoskeleton’s assistive profile, which mimics the gravitational torque of the arm, is potentially sub-optimal. Significance: This evaluation paper is the first to report reduced muscle fatigue and activity when working with an occupational shoulder exoskeleton providing one third of the gravitational torque of the arm during overhead work. These results stress the potential of occupational shoulder exoskeletons in overhead working situations and may direct towards longitudinal field experiments. Additionally, this experiment may stimulate future work to further investigate the effect of different assistive profiles.

6 September 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
MRMarco Rossini
Marco Rossini
SBSander De Bock
Sander De Bock
THTuur van der Have
Tuur van der Have
LFLouis Flynn
Louis Flynn
David Rodriguez-CiancaDavid Rodriguez-Cianca
David Rodriguez-Cianca
CGCarlos Rodriguez Guerrero
Carlos Rodriguez Guerrero
Exoskeleton technologies have the potential to reduce the prevalence of work-related musculoskeletal disorders. Despite the fast-growing industrial exoskeleton market, several bottlenecks have prevented their wide application, namely the lack of wearability, the amount of assistance they deliver and their usefulness in various working scenarios, outside of those they were specifically designed to perform. In this work we present the design, realization and evaluation of a new wearable shoulder exoskeleton that is kinematically compatible with the glenohumeral joint and features a new passive remote actuation system (pRAS). The latter has a twofold function: it delivers assistance only when needed and allows for a more convenient repositioning of the exoskeleton components, reducing the exoskeleton’s footprint and limiting the weight on the user’s arm. A test bench has been designed to validate the mechanical performance of the shoulder exoskeleton and experiments have been conducted to investigate its effect on users while executing overhead working tasks. Based on the muscle activity monitored in six subjects, we conclude that our exoskeleton reduces anterior deltoid activity by 22% during the execution of overhead work. This preliminary study suggests that our device can successfully provide relief at the level of the shoulder without hindering the subject.

6 April 2015 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
RJR. Jimenez-Fabian
R. Jimenez-Fabian
LFL. Flynn
L. Flynn
JGJoost Geeroms
Joost Geeroms
NVNicola Vitiello
Nicola Vitiello
Bram VanderborghtBram Vanderborght
Bram Vanderborght
DLDirk Lefeber
Dirk Lefeber
This paper describes a new design that improves several aspects of the mechanically adjustable compliance and controllable equilibrium position actuator (MACCEPA). The proposed design avoids premature wear and attachment issues found in the cable transmission used in previous MACCEPA designs and allows the use of high-performance compact compression springs. The mechanical configuration of the actuator provides an adjustable stiffness with a nonlinear stiffening output torque. The output position of the actuator and its global stiffness are independent from each other. In this work, we provide a mathematical description of the actuation principle along with an experimental verification of its performance in a powered ankle–foot prosthesis. This work is part of the CYBERLEGs project funded by the European Commissions 7th Framework Programme.

17 June 2017 in Autonomous Robots
Verified
Journal Article
Closed access
PDF file
JGJoost Geeroms
Joost Geeroms
LFLouis Flynn
Louis Flynn
RJRene Jimenez-Fabian
Rene Jimenez-Fabian
BVBram Vanderborght
Bram Vanderborght
DLDirk Lefeber
Dirk Lefeber