Carlos Castillo-Passi

Mr. Carlos Castillo-Passi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
CCCarlos Castillo-Passi
Carlos Castillo-Passi
RCRonal Coronado
Ronal Coronado
GVGabriel Varela‐Mattatall
Gabriel Varela‐Mattatall
CACarlos Alberola-López
Carlos Alberola-López
RBRene Botnar
Rene Botnar
PIPablo Irarrazaval
Pablo Irarrazaval
Purpose: To develop an open‐source, high‐performance, easy‐to‐use, extensible, cross‐platform, and general MRI simulation framework (Koma).Methods: Koma was developed using the Julia programming language. Like other MRI simulators, it solves the Bloch equations with CPU and GPU parallelization. The inputs are the scanner parameters, the phantom, and the pulse sequence that is Pulseq‐compatible. The raw data is stored in the ISMRMRD format. For the reconstruction, MRIReco.jl is used. A graphical user interface utilizing web technologies was also designed. Two types of experiments were performed: one to compare the quality of the results and the execution speed, and the second to compare its usability. Finally, the use of Koma in quantitative imaging was demonstrated by simulating Magnetic Resonance Fingerprinting (MRF) acquisitions.Results: Koma was compared to two well‐known open‐source MRI simulators, JEMRIS and MRiLab. Highly accurate results (with mean absolute differences below 0.1% compared to JEMRIS) and better GPU performance than MRiLab were demonstrated. In an experiment with students, Koma was proved to be easy to use, eight times faster on personal computers than JEMRIS, and 65% of test subjects recommended it. The potential for designing acquisition and reconstruction techniques was also shown through the simulation of MRF acquisitions, with conclusions that agree with the literature.Conclusions: Koma's speed and flexibility have the potential to make simulations more accessible for education and research. Koma is expected to be used for designing and testing novel pulse sequences before implementing them in the scanner with Pulseq files, and for creating synthetic data to train machine learning models.

27 July 2020 in IEEE Transactions on Pattern Analysis and Machine Intelligence
Verified
Journal Article
Closed access
GMGabriel della Maggiora
Gabriel della Maggiora
CCCarlos Castillo-Passi
Carlos Castillo-Passi
WQWenqi Qiu
Wenqi Qiu
SLShuang Liu
Shuang Liu
CMCarlos Milovic
Carlos Milovic
PIPablo Irarrazaval
Pablo Irarrazaval
The susceptibility of super paramagnetic iron oxide (SPIO) particles makes them a useful contrast agent for different purposes in MRI. These particles are typically quantified with relaxometry or by measuring the inhomogeneities they produced. These methods rely on the phase, which is unreliable for high concentrations. We present in this study a novel Deep Learning method to quantify the SPIO concentration distribution. We acquired the data with a new sequence called View Line in which the field map information is encoded in the geometry of the image. The novelty of our network is that it uses residual blocks as the bottleneck and multiple decoders to improve the gradient flow in the network. Each decoder predicts a different part of the wavelet decomposition of the concentration map. This decomposition improves the estimation of the concentration, and also it accelerates the convergence of the model. We tested our SPIO concentration reconstruction technique with simulated images and data from actual scans from phantoms. The simulations were done using images from the IXI dataset, and the phantoms consisted of plastic cylinders containing agar with SPIO particles at different concentrations. In both experiments, the model was able to quantify the distribution accurately.

16 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
CCCarlos Castillo-Passi
Carlos Castillo-Passi
KKKarl P. Kunze
Karl P. Kunze
MCMichael G. Crabb
Michael G. Crabb
CMCamila Munoz
Camila Munoz
AFAnastasia Fotaki
Anastasia Fotaki
RBRene Botnar
Rene Botnar
Purpose: To develop and evaluate a highly efficient free‐breathing and contrast‐agent‐free three‐dimensional (3D) whole‐heart Cardiac Magnetic Resonance Angiography (CMRA) sequence at 0.55T.Methods: Free‐breathing whole‐heart CMRA has been previously proposed at 1.5 and 3T. Direct application of this sequence to 0.55T is not possible due to changes in the magnetic properties of the tissues. To enable free‐breathing CMRA at 0.55T, pulse sequence design and acquisition parameters of a previously proposed whole‐heart CMRA framework are optimized via Bloch simulations. Image navigators (iNAVs) are used to enable nonrigid respiratory motion‐correction and 100% respiratory scan efficiency. Patch‐based low‐rank denoising is employed to accelerate the scan and account for the reduced signal‐to‐noise ratio at 0.55T. The proposed approach was evaluated on 11 healthy subjects. Image quality was assessed by a clinical expert (1: poor to 5: excellent) for all intrapericardiac structures. Quantitative evaluation was performed by assessing the vessel sharpness of the proximal right coronary artery (RCA).Results: Optimization resulted in an imaging flip angle of , fat saturation flip angle of , and six k‐space lines for iNAV encoding. The relevant cardiac structures and main coronary arteries were visible in all subjects, with excellent image quality (mean ) and minimal artifacts (mean ), with RCA vessel sharpness () comparable to previous studies at 1.5T.Conclusion: The proposed approach enables 3D whole‐heart CMRA at 0.55T in a 6‐min scan (), providing excellent image quality, minimal artifacts, and comparable vessel sharpness to previous 1.5T studies. Future work will include the evaluation of the proposed approach in patients with cardiovascular disease.

15 October 2022 in Synthetic Biology
Verified
Journal Article
Open access
PDF file
GVGonzalo Vidal
Gonzalo Vidal
CVCarolus Vitalis
Carolus Vitalis
MSMacarena Muñoz Silva
Macarena Muñoz Silva
CCCarlos Castillo-Passi
Carlos Castillo-Passi
GFGuillermo Yáñez Feliú
Guillermo Yáñez Feliú
CVCarlos Vidal-Céspedes
Carlos Vidal-Céspedes
Genetic circuits are subject to variability due to cellular and compositional contexts. Cells face changing internal states and environments, the cellular context, to which they sense and respond by changing their gene expression and growth rates. Furthermore, each gene in a genetic circuit operates in a compositional context of genes which may interact with each other and the host cell in complex ways. The context of genetic circuits can, therefore, change gene expression and growth rates, and measuring their dynamics is essential to understanding natural and synthetic regulatory networks that give rise to functional phenotypes. However, reconstruction of microbial gene expression and growth rate profiles from typical noisy measurements of cell populations is difficult due to the effects of noise at low cell densities among other factors. We present here a method for the estimation of dynamic microbial gene expression rates and growth rates from noisy measurement data. Compared to the current state-of-the-art, our method significantly reduced the mean squared error of reconstructions from simulated data of growth and gene expression rates, improving the estimation of timing and magnitude of relevant shapes of profiles. We applied our method to characterize a triple-reporter plasmid library combining multiple transcription units in different compositional and cellular contexts in Escherichia coli. Our analysis reveals cellular and compositional context effects on microbial growth and gene expression rate dynamics and suggests a method for the dynamic ratiometric characterization of constitutive promoters relative to an in vivo reference.

26 July 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
RCRonal Coronado
Ronal Coronado
GCGastao Cruz
Gastao Cruz
CCCarlos Castillo-Passi
Carlos Castillo-Passi
CTCristian Tejos
Cristian Tejos
SUsergio uribe
sergio uribe
PIPablo Irarrazaval
Pablo Irarrazaval
In MR Fingerprinting (MRF), balanced Steady-State Free Precession (bSSFP) has advantages over unbalanced SSFP because it retains the spin history achieving a higher signal-to-noise ratio (SNR) and scan efficiency. However, bSSFP-MRF is not frequently used because it is sensitive to off-resonance, producing artifacts and blurring, and affecting the parametric map quality. Here we propose a novel Spatial Off-resonance Correction (SOC) approach for reducing these artifacts in bSSFP-MRF with spiral trajectories. SOC-MRF uses each pixel’s Point Spread Function to create system matrices that encode both off-resonance and gridding effects. We iteratively compute the inverse of these matrices to reduce the artifacts. We evaluated the proposed method using brain simulations and actual MRF acquisitions of a standardized T1/T2 phantom and five healthy subjects. The results show that the off-resonance distortions in T1/T2 maps were considerably reduced using SOC-MRF. For T2, the Normalized Root Mean Square Error (NRMSE) was reduced from 17.3 to 8.3% (simulations) and from 35.1 to 14.9% (phantom). For T1, the NRMS was reduced from 14.7 to 7.7% (simulations) and from 17.7 to 6.7% (phantom). For in-vivo, the mean and standard deviation in different ROI in white and gray matter were significantly improved. For example, SOC-MRF estimated an average T2 for white matter of 77ms (the ground truth was 74ms) versus 50 ms of MRF. For the same example the standard deviation was reduced from 18 ms to 6ms. The corrections achieved with the proposed SOC-MRF may expand the potential applications of bSSFP-MRF, taking advantage of its better SNR property.

2 September 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
AAAnais Artiges
Anais Artiges
ASAmanpreet Singh Saimbhi
Amanpreet Singh Saimbhi
CCCarlos Castillo-Passi
Carlos Castillo-Passi
RLRiccardo Lattanzi
Riccardo Lattanzi
KBKai Tobias Block
Kai Tobias Block