Karl-Philipp Kunze

Karl-Philipp Kunze

Auto-generated profile, based on publicly available information

Karl-Philipp Kunze

School of Biomedical Engineering and Imaging Sciences King's College London London UK

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
KKKarl P. Kunze
Karl P. Kunze
SNStephan G. Nekolla
Stephan G. Nekolla
CRChristoph Rischpler
Christoph Rischpler
SZShelley HuaLei Zhang
Shelley HuaLei Zhang
CHCarmel Hayes
Carmel Hayes
MSMarkus Schwaiger
Markus Schwaiger

25 March 2024 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
RCR Crawley
R Crawley
KKK P Kunze
K P Kunze
XMX Milidonis
X Milidonis
JHJ Highton
J Highton
SMS McElroy
S McElroy
ACAmedeo Chiribiri
Amedeo Chiribiri
Current assessment of myocardial ischaemia from stress perfusion cardiovascular magnetic resonance (SP-CMR) largely relies on visual interpretation. This study investigated the use of high-resolution free-breathing SP-CMR with automated quantitative mapping in the diagnosis of coronary artery disease (CAD). Diagnostic performance was evaluated against invasive coronary angiography (ICA) with fractional flow reserve (FFR) measurement. Seven hundred and three patients were recruited for SP-CMR using the research sequence at 3 Tesla. Of those receiving ICA within 6 months, 80 patients had either FFR measurement or identification of a chronic total occlusion (CTO) with inducible perfusion defects seen on SP-CMR. Myocardial blood flow (MBF) maps were automatically generated in-line on the scanner following image acquisition at hyperaemic stress and rest, allowing myocardial perfusion reserve (MPR) calculation. Seventy-five coronary vessels assessed by FFR and 28 vessels with CTO were evaluated at both segmental and coronary territory level. Coronary territory stress MBF and MPR were reduced in FFR-positive (≤0.80) regions [median stress MBF: 1.74 (0.90–2.17) mL/min/g; MPR: 1.67 (1.10–1.89)] compared with FFR-negative regions [stress MBF: 2.50 (2.15–2.95) mL/min/g; MPR 2.35 (2.06–2.54) P < 0.001 for both]. Stress MBF ≤ 1.94 mL/min/g and MPR ≤ 1.97 accurately detected FFR-positive CAD on a per-vessel basis (area under the curve: 0.85 and 0.96, respectively; P < 0.001 for both). A novel scanner-integrated high-resolution free-breathing SP-CMR sequence with automated in-line perfusion mapping is presented which accurately detects functionally significant CAD. High-resolution free-breathing stress perfusion cardiovascular magnetic resonance (SP-CMR) with in-line automated quantitative mapping is accurate in the diagnosis of functionally significant coronary artery disease. Diagnostic performance was compared with invasive fractional flow reserve (FFR) with myocardial blood flow (MBF) at hyperaemic stress and myocardial perfusion reserve (MPR) reduced in patients with inducible ischaemia. CTO, chronic total occlusion; AUC, area under the curve.

1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
KKKarl P. Kunze
Karl P. Kunze
RDRalf Dirschinger
Ralf Dirschinger
HKHans Kossmann
Hans Kossmann
FHFranziska Hanus
Franziska Hanus
TITareq Ibrahim
Tareq Ibrahim
SNStephan G. Nekolla
Stephan G. Nekolla
Characterization of tissue integrity and inflammatory processes after acute myocardial infarction (AMI) using non-invasive imaging is predictive of patient outcome. Quantitative cardiovascular magnetic resonance (CMR) techniques such as native T1 and extracellular volume (ECV) mapping as well as 18F-FDG positron emission tomography (PET) imaging targeting inflammatory cell populations are gaining acceptance, but are often applied without assessing their quantitative potential. Using simultaneously acquired PET/CMR data from patients early after AMI, this study quantitatively compares these three imaging markers and investigates links to blood markers of myocardial injury and systemic inflammatory activity. A total of 25 patients without microvascular obstruction were retrospectively recruited. All imaging was simultaneously performed 5 ± 1 days after revascularization following AMI on an integrated 3T PET/MRI scanner. Native and post-contrast T1 data were acquired using a modified Look-Locker inversion recovery (MOLLI) sequence, ECV maps were calculated using individually sampled hematocrit. 18F-FDG PET was executed after 1 day of dietary preparation, 12 h of fasting, and administration of heparin. ECV, 18F-FDG and native T1 data were compared mutually as well as to peak counts of peripheral blood markers (creatine kinase, creatine kinase-MB, troponin, leukocytes, monocytes) and infarct size. High intra-patient correlations of relative ECV, 18F-FDG PET and native T1 signal increases were observed in combination with no inter-patient correlation of maximum absolute values at the infarct center, suggesting well-colocalized but physiologically diverse processes begetting the respective image signals. Comparison of maximum image signals to markers of myocardial damage and systemic inflammation yielded highly significant correlations of ECV to peak creatine kinase-MB and overall infarct size as well as between native T1 and peak monocyte counts. Absolute native T1 values at the infarct core early after AMI can be linked to the systemic inflammatory response independent of infarct size. Absolute ECV at the infarct core is related to both infarct size and blood markers of myocardial damage.

1 July 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
KKKarl P. Kunze
Karl P. Kunze
CRChristoph Rischpler
Christoph Rischpler
CHCarmel Hayes
Carmel Hayes
TITareq Ibrahim
Tareq Ibrahim
KLKarl-Ludwig Laugwitz
Karl-Ludwig Laugwitz
SNStephan G. Nekolla
Stephan G. Nekolla

15 October 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
CMCamila Munoz
Camila Munoz
RNRadhouene Neji
Radhouene Neji
KKKarl P. Kunze
Karl P. Kunze
SNStephan G. Nekolla
Stephan G. Nekolla
RBRene Botnar
Rene Botnar
CPClaudia Prieto
Claudia Prieto
Purpose: To develop a framework for efficient and simultaneous acquisition of motion‐compensated whole‐heart coronary MR angiography (CMRA) and left ventricular function by MR and myocardial integrity by PET on a 3T PET‐MR system.Methods: An acquisition scheme based on a dual‐phase CMRA sequence acquired simultaneously with cardiac PET data has been developed. The framework is integrated with a motion‐corrected image reconstruction approach, so that non‐rigid respiratory and cardiac deformation fields estimated from MR images are used to correct both the CMRA (respiratory motion correction for each cardiac phase) and the PET data (respiratory and cardiac motion correction). The proposed approach was tested in a cohort of 8 healthy subjects and 6 patients with coronary artery disease. Left ventricular (LV) function estimated from motion‐corrected dual‐phase CMRA was compared to the gold standard estimated from a stack of 2D CINE images for the healthy subjects. Relative increase of signal in motion‐corrected PET images compared to uncorrected images was computed for standard 17‐segment polar maps for each patient.Results: Motion‐corrected dual‐phase CMRA images allow for visualization of the coronary arteries in both systole and diastole for all healthy subjects and cardiac patients. LV functional indices from healthy subjects result in good agreement with the reference method, underestimating stroke volume by 3.07 ± 3.26 mL and ejection fraction by 0.30 ± 1.01%. Motion correction improved delineation of the myocardium in PET images, resulting in an increased 18F‐FDG signal of up to 28% in basal segments of the myocardial wall compared to uncorrected images.Conclusion: The proposed motion‐corrected dual‐phase CMRA and cardiac PET produces co‐registered good quality images in both modalities in a single efficient examination of ~13 min.

16 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
CCCarlos Castillo-Passi
Carlos Castillo-Passi
KKKarl P. Kunze
Karl P. Kunze
MCMichael G. Crabb
Michael G. Crabb
CMCamila Munoz
Camila Munoz
AFAnastasia Fotaki
Anastasia Fotaki
RBRene Botnar
Rene Botnar
Purpose: To develop and evaluate a highly efficient free‐breathing and contrast‐agent‐free three‐dimensional (3D) whole‐heart Cardiac Magnetic Resonance Angiography (CMRA) sequence at 0.55T.Methods: Free‐breathing whole‐heart CMRA has been previously proposed at 1.5 and 3T. Direct application of this sequence to 0.55T is not possible due to changes in the magnetic properties of the tissues. To enable free‐breathing CMRA at 0.55T, pulse sequence design and acquisition parameters of a previously proposed whole‐heart CMRA framework are optimized via Bloch simulations. Image navigators (iNAVs) are used to enable nonrigid respiratory motion‐correction and 100% respiratory scan efficiency. Patch‐based low‐rank denoising is employed to accelerate the scan and account for the reduced signal‐to‐noise ratio at 0.55T. The proposed approach was evaluated on 11 healthy subjects. Image quality was assessed by a clinical expert (1: poor to 5: excellent) for all intrapericardiac structures. Quantitative evaluation was performed by assessing the vessel sharpness of the proximal right coronary artery (RCA).Results: Optimization resulted in an imaging flip angle of , fat saturation flip angle of , and six k‐space lines for iNAV encoding. The relevant cardiac structures and main coronary arteries were visible in all subjects, with excellent image quality (mean ) and minimal artifacts (mean ), with RCA vessel sharpness () comparable to previous studies at 1.5T.Conclusion: The proposed approach enables 3D whole‐heart CMRA at 0.55T in a 6‐min scan (), providing excellent image quality, minimal artifacts, and comparable vessel sharpness to previous 1.5T studies. Future work will include the evaluation of the proposed approach in patients with cardiovascular disease.