Michael G. Crabb

Michael G. Crabb

Auto-generated profile, based on publicly available information

Michael G. Crabb

School of Biomedical Engineering and Imaging Sciences King's College London London UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2019 in 2D Materials
Verified
Journal Article
Closed access
NUN Unsuree
N Unsuree
HSH Selvi
H Selvi
MCM G Crabb
M G Crabb
JAJ A Alanis
J A Alanis
PPP Parkinson
P Parkinson
TETim Echtermeyer
Tim Echtermeyer
The design of efficient graphene-silicon (GSi) Schottky junction photodetectors requires detailed understanding of the spatial origin of the photoresponse. Scanning-photocurrent-microscopy (SPM) studies have been carried out in the visible wavelengths regions only, in which the response due to silicon is dominant. Here we present comparative SPM studies in the visible ( nm) and infrared ( nm) wavelength regions for a number of GSi Schottky junction photodetector architectures, revealing the photoresponse mechanisms for silicon and graphene dominated responses, respectively, and demonstrating the influence of electrostatics on the device performance. Local electric field enhancement at the graphene edges leads to a more than ten-fold increased photoresponse compared to the bulk of the graphene-silicon junction. Intentional design and patterning of such graphene edges is demonstrated as an efficient strategy to increase the overall photoresponse of the devices, leading to a more than two-fold responsivity enhancement under global illumination to 5 10 −6 A W −1 at a wavelength of 1650 nm for the patterned device compared to the unpatterned device. Complementary simulations and modeling illuminate observed effects and highlight the importance of considering graphene’s shape and pattern and device geometry in the device design.

13 June 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DSDongyue Si
Dongyue Si
MCMichael G. Crabb
Michael G. Crabb
KKKarl P. Kunze
Karl P. Kunze
SLSimon J. Littlewood
Simon J. Littlewood
CPClaudia Prieto
Claudia Prieto
RBRene Botnar
Rene Botnar
Purpose: To develop and validate a highly efficient motion compensated free‐breathing isotropic resolution 3D whole‐heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T.Methods: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion‐recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion‐compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look‐Locker inversion recovery and T2‐prepared balanced steady‐SSFP sequence.Results: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin‐echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good‐quality co‐registered 3D whole‐heart T1 and T2 maps with 2‐mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left‐ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look‐Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left‐ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2‐prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement.Conclusion: The proposed sequence simultaneously acquires 3D whole‐heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7‐min scan. Further investigation in patients with cardiovascular disease is now warranted.

16 October 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
CCCarlos Castillo-Passi
Carlos Castillo-Passi
KKKarl P. Kunze
Karl P. Kunze
MCMichael G. Crabb
Michael G. Crabb
CMCamila Munoz
Camila Munoz
AFAnastasia Fotaki
Anastasia Fotaki
RBRene Botnar
Rene Botnar
Purpose: To develop and evaluate a highly efficient free‐breathing and contrast‐agent‐free three‐dimensional (3D) whole‐heart Cardiac Magnetic Resonance Angiography (CMRA) sequence at 0.55T.Methods: Free‐breathing whole‐heart CMRA has been previously proposed at 1.5 and 3T. Direct application of this sequence to 0.55T is not possible due to changes in the magnetic properties of the tissues. To enable free‐breathing CMRA at 0.55T, pulse sequence design and acquisition parameters of a previously proposed whole‐heart CMRA framework are optimized via Bloch simulations. Image navigators (iNAVs) are used to enable nonrigid respiratory motion‐correction and 100% respiratory scan efficiency. Patch‐based low‐rank denoising is employed to accelerate the scan and account for the reduced signal‐to‐noise ratio at 0.55T. The proposed approach was evaluated on 11 healthy subjects. Image quality was assessed by a clinical expert (1: poor to 5: excellent) for all intrapericardiac structures. Quantitative evaluation was performed by assessing the vessel sharpness of the proximal right coronary artery (RCA).Results: Optimization resulted in an imaging flip angle of , fat saturation flip angle of , and six k‐space lines for iNAV encoding. The relevant cardiac structures and main coronary arteries were visible in all subjects, with excellent image quality (mean ) and minimal artifacts (mean ), with RCA vessel sharpness () comparable to previous studies at 1.5T.Conclusion: The proposed approach enables 3D whole‐heart CMRA at 0.55T in a 6‐min scan (), providing excellent image quality, minimal artifacts, and comparable vessel sharpness to previous 1.5T studies. Future work will include the evaluation of the proposed approach in patients with cardiovascular disease.

29 July 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DTDonovan P. Tripp
Donovan P. Tripp
KKKarl P. Kunze
Karl P. Kunze
MCMichael G. Crabb
Michael G. Crabb
CPClaudia Prieto
Claudia Prieto
RNRadhouene Neji
Radhouene Neji
RBRene Botnar
Rene Botnar
Purpose: To develop a framework for simultaneous three‐dimensional (3D) mapping of , , and fat signal fraction in the liver at 0.55 T.Methods: The proposed sequence acquires four interleaved 3D volumes with a two‐echo Dixon readout. and are encoded into each volume via preparation modules, and dictionary matching allows simultaneous estimation of , , and for water and fat separately. 2D image navigators permit respiratory binning, and motion fields from nonrigid registration between bins are used in a nonrigid respiratory‐motion‐corrected reconstruction, enabling 100% scan efficiency from a free‐breathing acquisition. The integrated nature of the framework ensures the resulting maps are always co‐registered.Results: , , and fat‐signal‐fraction measurements in phantoms correlated strongly (adjusted ) with reference measurements. Mean liver tissue parameter values in 10 healthy volunteers were , , and for , , and fat signal fraction, giving biases of , , and percentage points, respectively, when compared to conventional methods.Conclusion: A novel sequence for comprehensive characterization of liver tissue at 0.55 T was developed. The sequence provides co‐registered 3D , , and fat‐signal‐fraction maps with full coverage of the liver, from a single nine‐and‐a‐half‐minute free‐breathing scan. Further development is needed to achieve accurate proton‐density fat fraction (PDFF) estimation in vivo.

20 May 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
DSDongyue Si
Dongyue Si
MCMichael G. Crabb
Michael G. Crabb
SLSimon J. Littlewood
Simon J. Littlewood
KKKarl P. Kunze
Karl P. Kunze
JVJuliet Varghese
Juliet Varghese
RBRene Botnar
Rene Botnar
Purpose: To propose and validate a cardiac T 1 ρ mapping sequence at 0.55 T comparing continuous‐wave and adiabatic spin‐lock (SL) preparation pulses. Methods: The proposed 2D sequence acquires four single‐shot balanced SSFP readout images with differing contrasts in a single breath‐hold. The first three images are prepared with T 1 ρ preparation pulses with different durations, while the last image uses a saturation pulse immediately before data acquisition. The T 1 ρ map is calculated using a 3‐parameter fitting method. Bloch equation simulations were performed to optimize the parameters of the adiabatic‐SL pulses. Phantom studies and in vivo experiments in 10 healthy volunteers, a porcine myocardial infarction model, and a patient with suspected hypertrophic cardiomyopathy were performed to validate the performance of the proposed adiabatic T 1 ρ (T 1 ρ Ad ) mapping in comparison with conventional continuous‐wave T 1 ρ (T 1 ρ CW ) mapping. Results: The adiabatic‐SL pulse with simulation‐optimized parameters demonstrated robust performance despite B 0 and B 1 field inhomogeneities. Phantom T 1 ρ CW and T 1 ρ Ad mapping exhibited comparable precision. In vivo experiments on healthy volunteers showed that myocardial T 1 ρ Ad is higher than T 1 ρ CW (106.1 ± 7.1 vs. 47.0 ± 5.1 ms, p < 0.01) with better precision (11.4% ± 2.6% vs. 14.5% ± 2.1%, p < 0.01) and less spatial variation (10.9% ± 3.0% vs. 14.4% ± 3.4%, p < 0.01). Both T 1 ρ CW and T 1 ρ Ad mapping agreed with late gadolinium enhancement findings in the porcine model and the patient, and exhibited improved contrast compared to T 1 and T 2 mapping. Conclusion: Both T 1 ρ CW and T 1 ρ Ad are promising for non‐contrast detection of various cardiomyopathies at 0.55 T, but T 1 ρ Ad demonstrates better spatial uniformity than T 1 ρ CW .

22 December 2025 in NMR in Biomedicine
Verified
Journal Article
Open access
MCMichael G. Crabb
Michael G. Crabb
KKKarl P. Kunze
Karl P. Kunze
CCCarlos Castillo-Passi
Carlos Castillo-Passi
DSDongyue Si
Dongyue Si
SLSimon J. Littlewood
Simon J. Littlewood
RBRene Botnar
Rene Botnar
Myocardial maps are conventionally acquired in 2D breath‐hold single‐parameter scans that are slow and have limited heart coverage. To overcome limitations associated with 2D breath‐hold mapping sequences, we develop a novel free‐breathing 3D joint / mapping sequence with Dixon encoding to provide co‐registered 3D and maps and water‐fat volumes with isotropic spatial resolution in a single scan for comprehensive contrast‐agent free myocardial tissue characterization and visualisation of the whole‐heart anatomy on a clinical 0.55‐T MR scanner. The proposed sequence acquires four interleaved 3D volumes with preparation modules to provide and encoding, with data acquired with a two‐echo Dixon readout and 2D image navigators to enable respiratory scan efficiency. Images were reconstructed with nonrigid respiratory motion‐corrected iterative SENSE with multi‐dimensional low‐rank patch‐based denoising, and maps generated by matching with simulated dictionaries. The proposed sequence was tested in phantoms, 11 healthy subjects and 1 patient, and compared with conventional techniques. For phantoms, the proposed 3D and measurements showed good correlation with 2D spin‐echo reference measurements. For healthy subjects, septal myocardial tissue mapping values were and for the proposed sequence, against and for 2D modified Look‐Locker inversion recovery and 2D respectively. Promising results were obtained when the proposed mapping was compared to 2D late‐gadolinium enhancement imaging in a patient. The proposed approach enables simultaneous 3D whole‐heart joint / mapping and water‐fat imaging at 0.55 T in a single scan of min, demonstrating good agreement with conventional techniques in phantoms and healthy subjects, and promising results in a patient.