Muscles play an indispensable role in human life. Surface electromyography (sEMG), as a non-invasive method, is crucial for monitoring muscle status. It is characterized by its real-time, portable nature and is extensively utilized in sports and rehabilitation sciences. This study proposed a wireless acquisition system based on multi-channel sEMG for objective monitoring of grip force. The system consists of an sEMG acquisition module containing four-channel discrete terminals and a host computer receiver module, using Bluetooth wireless transmission. The system is portable, wearable, low-cost, and easy to operate. Leveraging the system, an experiment for grip force prediction was designed, employing the bald eagle search (BES) algorithm to enhance the Random Forest (RF) algorithm. This approach established a grip force prediction model based on dual-channel sEMG signals. As tested, the performance of acquisition terminal proceeded as follows: the gain was up to 1125 times, and the common mode rejection ratio (CMRR) remained high in the sEMG signal band range (96.94 dB (100 Hz), 84.12 dB (500 Hz)), while the performance of the grip force prediction algorithm had an R2 of 0.9215, an MAE of 1.0637, and an MSE of 1.7479. The proposed system demonstrates excellent performance in real-time signal acquisition and grip force prediction, proving to be an effective muscle status monitoring tool for rehabilitation, training, disease condition surveillance and scientific fitness applications.
Micro-electro-mechanical system (MEMS) pressure sensors play a significant role in pulse wave acquisition. However, existing MEMS pulse pressure sensors bound with a flexible substrate by gold wire are vulnerable to crush fractures, leading to sensor failure. Additionally, establishing an effective mapping between the array sensor signal and pulse width remains a challenge. To solve the above problems, we propose a 24-channel pulse signal acquisition system based on a novel MEMS pressure sensor with a through-silicon-via (TSV) structure, which connects directly to a flexible substrate without gold wire bonding. Firstly, based on the MEMS sensor, we designed a 24-channel pressure sensor flexible array to collect the pulse waves and static pressure. Secondly, we developed a customized pulse preprocessing chip to process the signals. Finally, we built an algorithm to reconstruct the three-dimensional pulse wave from the array signal and calculate the pulse width. The experiments verify the high sensitivity and effectiveness of the sensor array. In particular, the measurement results of pulse width are highly positively correlated with those obtained via infrared images. The small-size sensor and custom-designed acquisition chip meet the needs of wearability and portability, meaning that it has significant research value and commercial prospects.
The pulse carries important physiological and pathological information about the human body. The piezoresistive sensor used to capture vascular pulsation information has transitioned from a single-point to a sensor array. However, the interference signal between channels has become a key bottleneck restricting the development of the sensor array pulse diagnosis equipment. The sensor in contact with vascular pulsation obtains the pulse signal. When some sensors are displaced due to vascular pulsation, other sensors will be driven to move, which will produce interference signals. Signal interference is a common problem for sensor arrays, but few people have analyzed this problem from the perspective of the algorithm. In this paper, an interference signal recognition algorithm of the sensor array based on a convolutional neural network (CNN) is proposed. Firstly, a simple mechanical structure model was established to analyze the generation mechanism of interference signals in one MEMS sensor array acquisition system. Then, a CNN model with fewer parameters was designed for identifying interference signals. Finally, the CNN model was implemented on a field-programmable gate array (FPGA). The results show that the CNN algorithm could identify interference signals well, and the accuracy of the algorithm was 99.3%. The power consumption of the CNN accelerator was 0.673 W at a working frequency of 100 MHz. The interference signal identification algorithm is proposed to ensure the accurate analysis of array signals. FPGA implementation lays the foundation for the miniaturization and portability of the equipment.
Radial pulse signals are produced by the periodic ejection of blood from the heart, and physiological and pathological information of the human body can be analyzed by extracting the time-domain characteristics of pulse waves. However, since pulse signals are weak physiological signals on the body surface and complex, the acquisition of pulse characteristics using the traditional curvature method will produce a large error, which cannot meet the needs of pulse wave analysis in current clinical practice. To solve this problem, a multi-morphological pulse signal feature recognition algorithm based on the one-dimensional deep convolutional neural network (1D-DCNN) model is proposed. We used the multi-channel pulse diagnosis instrument independently developed by the team to collect radial pulse signals under continuous pressure of the test subjects and collected 115 subjects and extracted a total of 1300 single-cycle pulse signals and then divided these pulse signals into 6 different forms. Five types of pulse signal time-domain feature points were labeled, and five independent feature point datasets were labeled and formed five customized neural network models that were generated to train and identify the pulse feature point datasets independently. The results show that the correction coefficient () of the multi-class pulse signal processing algorithm proposed in this paper for each type of feature point recognition reaches more than 0.92. The performance is significantly better than that of the traditional curvature method, which shows the accuracy and superiority of the proposed method. Therefore, the multi-class pulse signal characteristic parameter recognition model based on the 1D-DCNN model proposed in this paper can efficiently and accurately identify pulse time-domain characteristic parameters, which can be applied to discriminate time-domain pulse information in clinical practice and assist doctors in diagnosis.