Continuous monitoring of pulse waves plays a significant role in reflecting physical conditions and disease diagnosis. However, the current collection equipment cannot simultaneously achieve wearable and continuous monitoring under varying pressure and provide personalized pulse wave monitoring targeted different human bodies. To solve the above problems, this paper proposed a novel wearable and real-time pulse wave monitoring system based on a novel flexible compound sensor. Firstly, a custom-packaged pressure sensor, a signal stabilization structure, and a micro pressurization system make up the flexible compound sensor to complete the stable acquisition of pulse wave signals under continuously varying pressure. Secondly, a real-time algorithm completes the analysis of the trend of the pulse wave peak, which can quickly and accurately locate the best pulse wave for different individuals. Finally, the experimental results show that the wearable system can both realize continuous monitoring and reflecting trend differences and quickly locate the best pulse wave for different individuals with the 95% accuracy. The weight of the whole system is only 52.775 g, the working current is 46 mA, and the power consumption is 160 mW. Its small size and low power consumption meet wearable and portable scenarios, which has significant research value and commercialization prospects.
Muscles play an indispensable role in human life. Surface electromyography (sEMG), as a non-invasive method, is crucial for monitoring muscle status. It is characterized by its real-time, portable nature and is extensively utilized in sports and rehabilitation sciences. This study proposed a wireless acquisition system based on multi-channel sEMG for objective monitoring of grip force. The system consists of an sEMG acquisition module containing four-channel discrete terminals and a host computer receiver module, using Bluetooth wireless transmission. The system is portable, wearable, low-cost, and easy to operate. Leveraging the system, an experiment for grip force prediction was designed, employing the bald eagle search (BES) algorithm to enhance the Random Forest (RF) algorithm. This approach established a grip force prediction model based on dual-channel sEMG signals. As tested, the performance of acquisition terminal proceeded as follows: the gain was up to 1125 times, and the common mode rejection ratio (CMRR) remained high in the sEMG signal band range (96.94 dB (100 Hz), 84.12 dB (500 Hz)), while the performance of the grip force prediction algorithm had an R2 of 0.9215, an MAE of 1.0637, and an MSE of 1.7479. The proposed system demonstrates excellent performance in real-time signal acquisition and grip force prediction, proving to be an effective muscle status monitoring tool for rehabilitation, training, disease condition surveillance and scientific fitness applications.
Micro-electro-mechanical system (MEMS) pressure sensors play a significant role in pulse wave acquisition. However, existing MEMS pulse pressure sensors bound with a flexible substrate by gold wire are vulnerable to crush fractures, leading to sensor failure. Additionally, establishing an effective mapping between the array sensor signal and pulse width remains a challenge. To solve the above problems, we propose a 24-channel pulse signal acquisition system based on a novel MEMS pressure sensor with a through-silicon-via (TSV) structure, which connects directly to a flexible substrate without gold wire bonding. Firstly, based on the MEMS sensor, we designed a 24-channel pressure sensor flexible array to collect the pulse waves and static pressure. Secondly, we developed a customized pulse preprocessing chip to process the signals. Finally, we built an algorithm to reconstruct the three-dimensional pulse wave from the array signal and calculate the pulse width. The experiments verify the high sensitivity and effectiveness of the sensor array. In particular, the measurement results of pulse width are highly positively correlated with those obtained via infrared images. The small-size sensor and custom-designed acquisition chip meet the needs of wearability and portability, meaning that it has significant research value and commercial prospects.
The pulse carries important physiological and pathological information about the human body. The piezoresistive sensor used to capture vascular pulsation information has transitioned from a single-point to a sensor array. However, the interference signal between channels has become a key bottleneck restricting the development of the sensor array pulse diagnosis equipment. The sensor in contact with vascular pulsation obtains the pulse signal. When some sensors are displaced due to vascular pulsation, other sensors will be driven to move, which will produce interference signals. Signal interference is a common problem for sensor arrays, but few people have analyzed this problem from the perspective of the algorithm. In this paper, an interference signal recognition algorithm of the sensor array based on a convolutional neural network (CNN) is proposed. Firstly, a simple mechanical structure model was established to analyze the generation mechanism of interference signals in one MEMS sensor array acquisition system. Then, a CNN model with fewer parameters was designed for identifying interference signals. Finally, the CNN model was implemented on a field-programmable gate array (FPGA). The results show that the CNN algorithm could identify interference signals well, and the accuracy of the algorithm was 99.3%. The power consumption of the CNN accelerator was 0.673 W at a working frequency of 100 MHz. The interference signal identification algorithm is proposed to ensure the accurate analysis of array signals. FPGA implementation lays the foundation for the miniaturization and portability of the equipment.
In pulse wave analysis, the changing curve of pulse wave strength with continuous increasing pressure, that is, the P-S (pressure-strength) curve, contains abundant human physiological information, but there is no accurate model to describe the formation mechanism of the curve. Therefore, this paper proposes a modeling method of the radial artery P-S curve based on the radial vibration of the vascular wall. The modeling method includes three parts. Firstly, based on hemodynamics, we proposed the blood motion equation in the pulsation process of healthy people. Secondly, the motion equation of the vascular wall based on the fluid–structure interaction between blood motion and vascular wall was established. Finally, according to the elastic theory of the vascular wall, the relationship between pulse strength and extravascular pressure of blood vessels was found. To verify the accuracy and applicability of the model, this paper simulated the changes in the vascular wall stress and the intravascular pressure with the extravascular pressure during the process of vascular deformation. In addition, 69 healthy volunteers were selected to participate in this study. Based on the gradient compression, the pulse strength envelope under the continuous pressure sequence of the radial artery, namely the pulse P-S curve, was extracted. We also analyzed the relationship between the individual P-S curve difference and BMI. The results show that the actual human body data collection and analysis results are consistent with the theoretical model established in this paper, which indicates that the model can provide a novel idea for the evaluation of the state of the human body.
Pulse wave signal sensed over the radial artery on the wrist is a crucial physiological indicator in disease diagnosis. The sensor array composed of multiple sensors has the ability to collect abundant pulse wave information. As a result, it has gradually attracted the attention of practitioners. However, few practical methods are used to obtain a one-dimensional pulse wave from the sensor array’s spatial multi-dimensional signals. The current algorithm using pulse wave with the highest amplitude value as the significant data suffers from low consistency because the signal acquired each time differs significantly due to the sensor’s relative position shift to the test area. This paper proposes a processing method based on time series similarity, which can take full advantage of sensor arrays’ spatial multi-dimensional characteristics and effectively avoid the above factors’ influence. A pulse wave acquisition system (PWAS) containing a micro-electro-mechanical system (MEMS) sensor array is continuously extruded using a stable dynamic pressure input source to simulate the pulse wave acquisition process. Experiments are conducted at multiple test locations with multiple data acquisitions to evaluate the performance of the algorithm. The experimental results show that the newly proposed processing method using time series similarity as the criterion has better consistency and stability.