Stanislav Jochim

Mr. Stanislav Jochim

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Linda Makovicka OsvaldovaLinda Makovicka Osvaldova
Linda Makovicka Osvaldova
Iveta MarkovaIveta Markova
Iveta Markova
SJStanislav Jochim
Stanislav Jochim
JBJan Bares
Jan Bares
Straw, a natural cellulose-based material, has become part of building elements. Eco-panels, compressed straw in a cardboard casing, is used as building insulation. Eco-panel is a secondary product with excellent insulating properties. If suitably fire-treated (insulation and covering), straw panels’ fire resistance may be increased. This contribution deals with monitoring the behavior of eco-panels exposed to a small ignition initiator (flame). The samples consisted of compressed straw boards coated with a 40 mm thick cardboard. Samples were exposed to a flame for 5 and 10 min. The influence of the selected factors (size of the board, orientation of flame with the sample) were compared on the basis of experimentally obtained data: mass loss. The results obtained do not show a statistically significant influence of the position of the sample and the initiating source (flame). The results presented in the article confirm the justifiability of fire tests. As the results of the experiments prove, the position of a small burner for igniting such material is also important. Such weakness of the material can also be eliminated by design solutions in the construction. The experiment on larger samples also confirmed the justifiability of fire tests along with the need for flame retardancy of such material for its safe application in construction.

3 April 2025 in Materials
Verified
Journal Article
Open access
PDF file
Richard HrčkaRichard Hrčka
Richard Hrčka
PŠPatrik Štompf
Patrik Štompf
SJStanislav Jochim
Stanislav Jochim
MMMarek Eduard Mikuš
Marek Eduard Mikuš
MIMilan Iskra
Milan Iskra
The construction industry is facing an increased demand to adopt sustainable green building materials to minimize the carbon footprint. Hemp concrete is a green building material not only because of its low embodied carbon but also because of its ability to regulate heat and relative humidity. Its thermal characteristics are often viewed as favorable for reducing the energy used to heat or cool indoor buildings. The current research is focused on the properties of hemp concrete from Slovak manufacturers which can be effectively used in construction as a replacement for conventional building materials and can also be effectively applied in building renovations. The basic thermal properties of hemp concrete, i.e., specific heat capacity, thermal conductivity, effusivity, thermal diffusivity, and lag time, were determined. The determination of all properties is dependent on the knowledge of heat fluxes at the surface and the density of samples. The insulation ability was expressed with a thermal conductivity of 0.099 W·m−1·K−1. The accumulation was expressed with a specific heat of 1540 J·kg−1·K−1 and density of 322 kg·m−3 in the air environment temperature of 22 °C and relative humidity of 50%. To assess moisture properties, the moisture content and the speed of molecules during diffusion and lag time, based on the thickness of the hemp concrete samples, were measured. The speed of water molecules during diffusion in hemp concrete was 8.6 × 10−7 m·s−1. The study shows that hemp concrete has interesting hydrothermal properties for use as an insulation layer in envelope structures. Thus, this material can be used effectively in the construction field in order to meet the requirements of the current standards, which aim to reduce energy and environmental impacts.

9 July 2025 in Forests
Verified
Journal Article
Open access
PDF file
RURóbert Uhrín
Róbert Uhrín
SJStanislav Jochim
Stanislav Jochim
Vlastimil BorůvkaVlastimil Borůvka
Vlastimil Borůvka
Milos PavelekMilos Pavelek
Milos Pavelek
PSPavol Sedlák
Pavol Sedlák
Katarína StřelcováKatarína Střelcová
Katarína Střelcová
The global climate crisis has shifted the building industry toward the ecological use of materials, often based on renewable sources. Properties of such materials, as well as their behavior in structures, need to be constantly verified both theoretically and experimentally. This article focuses on the influence of vapor retarder on the moisture content of timber log wall structures with sheep wool insulation. Moisture content was verified experimentally during the period of over 2 years with monitoring sensors and insulation samples weighing. Results show that vapor retarder has a positive and statistically significant impact on the moisture content of sheep wool insulation and log structure, depending on the season and position of insulation in the structure. The moisture content of the log structure does not exceed 16%, confirming no risk of biodegradation during the monitored period. This case study can help further the knowledge of log structure design and provide insight into the hygrothermal properties of sandwich structures.

7 December 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SJStanislav Jochim
Stanislav Jochim
RURóbert Uhrín
Róbert Uhrín
JSJarmila Schmidtová
Jarmila Schmidtová
PSPavol Sedlák
Pavol Sedlák
DBDominika Búryová
Dominika Búryová
Katarína StřelcováKatarína Střelcová
Katarína Střelcová
The paper is focused on a verification of the moisture content of fiberboard insulations in the multilayer loadbearing log wall designed with and without the vapor barrier. Experimental verification was done using a sample of the multilayer loadbearing log wall built in a research timber structure building under in-situ conditions. Indoor properties of the building met conditions for human occupancy. The experiment was performed for 2 years and 3 months. Aims of the fiberboard insulations moisture content verification in the walls were to verify the effect of vapor barrier in various periods of the year and verify excessive moisture in the fiberboard insulations, which is undesirable in terms of biodegradation. The results of measuring the moisture content showed that after a certain period, the difference of insulation moisture content in the wall including and excluding vapor barrier is negligible, as well as other results and conclusions for designing the composition of multilayer loadbearing log walls.

25 July 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
PŠPatrik Štompf
Patrik Štompf
RVRozália Vaňová
Rozália Vaňová
SJStanislav Jochim
Stanislav Jochim
Renovating existing buildings is a key strategy for achieving the EU’s climate targets, as over 75% of the current building stock is energy inefficient. This study evaluates the environmental impacts of three façade renovation scenarios for an office building at the Technical University in Zvolen (Slovakia) using a life cycle assessment (LCA) approach. The aim is to quantify and compare these impacts based on material selection and its influence on sustainable construction. The analysis focuses on key environmental indicators, including global warming potential (GWP), abiotic depletion (ADE, ADF), ozone depletion (ODP), toxicity, acidification (AP), eutrophication potential (EP), and primary energy use (PERT, PENRT). The scenarios vary in the use of insulation materials (glass wool, wood fibre, mineral wool), façade finishes (cladding vs. render), and window types (aluminium vs. wood–aluminium). Uncertainty analysis identified GWP, AP, and ODP as robust decision-making categories, while toxicity-related results showed lower reliability. To support integrated and transparent comparison, a composite environmental index (CEI) was developed, aggregating characterisation, normalisation, and mass-based results into a single score. Scenario C–2, featuring an ETICS system with mineral wool insulation and wood–aluminium windows, achieved the lowest environmental impact across all categories. In contrast, scenarios with traditional cladding and aluminium windows showed significantly higher impacts, particularly in fossil fuel use and ecotoxicity. The findings underscore the decisive role of material selection in sustainable renovation and the need for a multi-criteria, context-sensitive approach aligned with architectural, functional, and regional priorities.

13 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
RURóbert Uhrín
Róbert Uhrín
SJStanislav Jochim
Stanislav Jochim
Vlastimil BorůvkaVlastimil Borůvka
Vlastimil Borůvka
Milos PavelekMilos Pavelek
Milos Pavelek
PSPavol Sedlák
Pavol Sedlák
Katarína StřelcováKatarína Střelcová
Katarína Střelcová
Global climate crisis shifts the building industry towards ecological use of materials, often based on renewable sources. Properties of such materials, as well as their behavior in structures, need to be constantly verified both theoretically and experimentally. The article focuses on vapor retarder influence on moisture content of timber log peripheral wall structures with sheep wool insulation. Moisture content was verified experimentally during the period of over 2 years via monitoring sensors and insulation samples weighing. Results show vapor retarder has got a positive and statistically significant impact on moisture content of sheep wool insulation and log structure. This case study can help further the knowledge of log structure design and provide insight into hygrothermal properties of sandwich structures.