Lou Fengfei

Ms. Lou Fengfei


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2023 in Gels
Verified
Journal Article
Open access
PDF file
LFLou Fengfei
Lou Fengfei
SDSujun Dong
Sujun Dong
KZKeyong Zhu
Keyong Zhu
XCXiaona Chen
Xiaona Chen
YMYinwei Ma
Yinwei Ma
Due to the extremely high porosity and extremely low density of nano-porous thermal insulation materials, the characteristic size of the pores inside the materials and the characteristic size of the solid skeleton structure are on the nanometer scale, which leads to the obvious nanoscale effect of the heat transfer law inside the aerogel materials. Therefore, the nanoscale heat transfer characteristics inside the aerogel materials and the existing mathematical models for calculating the thermal conductivity of various heat transfer modes at the nanoscale need to be summarized in detail. Moreover, in order to verify the accuracy of the thermal conductivity calculation model of aerogel nano-porous materials, correct experimental data are required to modify the model. Because the medium is involved in radiation heat transfer, the existing test methods have a large error, which brings great difficulties to the design of nano-porous materials. In this paper, the heat transfer mechanism, characterization methods, and test methods of thermal conductivity of nano-porous materials are summarized and discussed. The main contents of this review are as follows. The first part introduces the structural characteristics and specific application environment of aerogel. In the second part, the characteristics of nanoscale heat transfer of aerogel insulation materials are analyzed. In the third part, the characterization methods of thermal conductivity of aerogel insulation materials are summarized. In the fourth part, the test methods of thermal conductivity of aerogel insulation materials are summarized. The fifth part gives a brief conclusion and prospect.

3 December 2021 in Gels
Verified
Journal Article
Open access
PDF file
LFLou Fengfei
Lou Fengfei
SDSujun Dong
Sujun Dong
YMYinwei Ma
Yinwei Ma
BQBin Qi
Bin Qi
KZKeyong Zhu
Keyong Zhu
For aerogels in metal thermal protection system (MTPS), radiative heat transfer will participate in the thermal transport process. Therefore, the influence of the emissivity of the coupling interface between metal and aerogels on thermal insulation performance is considered an important research focus. In this paper, CFD numerical simulation is performed to study the influence of emissivity on the performance with different extinction coefficients at different boundary temperatures. The finite volume method and the discrete ordinate method are used to solve the govern equations. The results show that when the boundary temperatures are 600 K and 2100 K, the extinction coefficient is 50 m−1, and the reduction percentage of the effective thermal conductivity with an emissivity of 0.2 can be up to 47.5% and 69.8%, compared to the system with an emissivity of 1. Thus, the reduction in emissivity has a good effect on the thermal insulation performance of the MTPS at a higher boundary temperature for materials with small extinction coefficients.

7 June 2026 in Gels
Verified
Journal Article
Open access
PDF file
LFLou Fengfei
Lou Fengfei
SDSujun Dong
Sujun Dong
XLXia Liu
Xia Liu
HFHaitao Fan
Haitao Fan
XWXun Wang
Xun Wang
YMYinwei Ma
Yinwei Ma
Radiative heat transfer in aerogels (semi-transparent materials) acts as a participating medium, causing notable errors in conventional steady-state thermal conductivity measurements. Coupled conduction–radiation heat transfer is numerically simulated to examine the influence of variations in the heating plate-specimen interface emissivity on thermal conductivity measurements, and the simulation results are experimentally validated using test systems with differing interface emissivities. The results show that the effect of interface emissivity on effective thermal conductivity is more obvious under high temperatures and low extinction coefficients. When the average temperature is 1273 K, the emissivity decreases from 1 to 0.2, and the effective thermal conductivity with extinction coefficients of 3.5 m−1 and 3500 m−1 decreases by 76.1% and 24.1%, respectively. Experimental results show that when the hot surface temperature is 873 K, the cold surface temperature differences in different test systems can reach 30 K. The experimental results have the same trend as the steady-state simulation results, which verifies the accuracy of the numerical simulations. Quantitative analysis of the steady-state heating measurement results demonstrates the effect of medium radiation in semi-transparent materials on the obtained results. The findings contribute to a more accurate characterization of silica aerogel composites and provide new insights into the influence of radiative heat transfer on thermal conductivity evaluation in semi-transparent aerogel materials, which is important for the development and application of aerogel-based thermal insulation systems.

6 October 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
RWRi Wang
Ri Wang
LFLou Fengfei
Lou Fengfei
BQBin Qi
Bin Qi
RARong A
Rong A
YZYuanye Zhou
Yuanye Zhou
SDSujun Dong
Sujun Dong
In this paper, aimed at the problem of large temperature gradient thermal testing with the typical sharp wedge leading edge structure of a hypersonic vehicle, a subsonic high-temperature combustion gas heating (SHCH) test device is used to conduct a series of experiments on the heat flux simulation ability of subsonic high-temperature combustion gas in the stagnation point region. Firstly, for a hypersonic vehicle with a flying height of 24 km and Mach number range of 4~6.5, the stagnation point heat flux in the head area is obtained by numerical calculation of a typical leading edge structure, which is used as the experimental target of the thermal structure test. Secondly, an experimental specimen with a Gardon heat flux meter is designed with the same shape and size as the specimen in the numerical simulations to prepare for the subsequent SHCH test. Thirdly, a method to determine the combustion gas temperature based on a Kriging surrogate model is proposed. CFD numerical simulation is conducted using the SHCH test model, and the numerical calculation results are used as the training dataset. The Kriging surrogate model is used to establish an approximate fitting relationship between the stagnation point heat flux and experimental parameters under SHCH conditions. The corresponding combustion gas temperature values are found, respectively, with the hypersonic aerodynamic heat flux at Mach 5.0~5.4 as the target value. Finally, stagnation point heat flux testing of low-speed and high-temperature combustion gas is performed at different combustion gas temperatures. The experimental and target values obtained from hypersonic aerodynamic thermal simulations are compared and analyzed to verify the heating capacity of SHCH and the feasibility of hypersonic aerothermal simulation testing.