Objective: The cast-in-place steel spring floating slab track (SSFST) is difficult to maintain and repair, while the mechanical strength of the end of the traditional prefabricated SSFST is poor. In order to overcome the above shortcomings, a shear-hinge-combined prefabricated SSFST was developed, and an indoor test was carried out to analyze its vibration-damping effect. Methods: A combined shear hinge SSFST connection model with two length sizes was established. The dynamic response amplitude and frequency response characteristics of the foundation (ground) under different isolator installations and fatigue loads were studied, and the vibration-damping performance of two sizes of combined shear hinge SSFST was evaluated. Results: The vibration-damping effect of the steel spring vibration isolator mainly acts in the middle and low-frequency bands of 16–400 Hz, and the vibration near 10 Hz will be aggravated after the vibration isolator is installed. The vibration index and variation law of the two sizes of SSFST are similar, and the vibration response of 4.8 m SSFST is slightly less than 3.6 m SSFST. There is almost no change in each index when the load is 5 million times, and there is a certain range of change when the load is 10 million times, but the overall change is small. Conclusions: The combined shear hinge prefabricated SSFST can have an excellent isolation effect on vibration and can still maintain good vibration-damping ability within 10 million fatigue loads (about 5 years); 4.8 m SSFST should be laid in straight sections with higher train speeds, while 3.6 m SSFST should be applied in curved sections to ensure smooth lines.
To meet the transportation requirements of heavy-haul trains, it is necessary to consider the use of prestressed reinforced concrete ballastless tracks. Therefore, the CRTSIII SBT (China Railway Track System III-type slab ballastless track) has been considered for its convenient construction and geometric adjustment. Considering the problems existing in the base plate of CRTSIII SBT in heavy-haul applications, an indoor test and simulation were conducted to explore the cracking phenomenon of the base plate concrete under fatigue load. The reliability of the simulation was verified through the experimental results. A fatigue crack development law of the base plate structure was established. Furthermore, the influence of the load position, the thickness of self-compacting concrete and axle loads on the fatigue damage of the base plate structure were investigated. For the CRTSIII SBT subjected to heavier axle loads, it is appropriate to thicken the self-compacting concrete layer and strengthen the concrete and steel reinforcement at the plate end to reduce fatigue damage and cracks. The research results can serve as a basis for the optimization of the CRTSIII SBT base plate structure in heavy-haul railway applications.
With the gradual increase of the cargo weight of heavy-haul trains, the traditional ballasted track with the accumulation of stone and ballast has been unable to meet its structural safety requirements. From the comparison of the three common ballastless tracks in China, it can be seen that the low-vibration track (LVT) has the advantages of reasonable structure, low cost, and easy maintenance. Therefore, the design and research of heavy-haul railways are focused on, and it is urgent to study the applicability of LVT in heavy-haul railways. Method: By improving the slope of the short side of the LVT support block, the support block has a better load bearing capacity, so as to achieve the purpose of bearing a larger axle load. Through 1:1 full-scale model test and finite element simulation, the static mechanical properties of Improved LVT (ILVT) and Traditional LVT (TLVT) are compared and analyzed. Result: Compared with TLVT, ILVT has smaller vertical displacement and track gauge changes when subjected to the same load. The proven and reliable finite element model also shows that ILVT’s load sharing is less affected. In the case of achieving the same deformation, ILVT can withstand greater vertical and lateral loads. Conclusions: Compared with the TLVT, the ILVT design can reduce the vertical displacement of the rail and the supporting block, better control the track subsidence, and improve the driving safety of the LVT. At the same time, ILVT improves the anti-overturning ability of the rail and support block under lateral load, reduces the expansion of the gauge and the lateral spacing of the support block, and improves the stability of the track structure. ILVT can also be considered for the weight of 40t and other large axle load, and has broad application prospects.
Background: In order to study the applicability of Low Vibration Track (LVT) in heavy-haul railway tunnels, this paper carried out research on the dynamic effects of LVT heavy-haul railway wheels and rails and provided a technical reference for the structural design of heavy-haul railway track structures. Methods: Based on system dynamics response sensitivity and vehicle-track coupling dynamics, the stability of the upper heavy-haul train, the track deformation tendency, and the dynamic response sensitivity of the vehicle-track system under the influence of random track irregularity and different track structure parameters were calculated, compared and analyzed. Results: Larger under-rail lateral and vertical structural stiffness can reduce the dynamic response of the rail system. The vertical and lateral stiffness under the block should be set within a reasonable range to achieve the purpose of reducing the dynamic response of the system, and beyond a certain range, the dynamic response of the rail system will increase significantly, which will affect the safety and stability of train operation. Conclusions: Considering the changes of track vehicle body stability coefficients, the change of deformation control coefficients, and the sensitivity indexes of dynamic performance coefficients to track structure stiffness change, the recommended values of the vertical stiffness under rail, the lateral stiffness under rail, the vertical stiffness under block, and the lateral stiffness under block are, respectively 160 kN/mm, 200 kN/mm, 100 kN/mm, and 200 kN/mm.
Purpose: Steel-spring-floating slab tracks are widely used in subway lines. It is necessary to analyze and study the vibration damping and transmission characteristics of the steel-spring-floating slab track in various frequency bands under the action of train loads. Method: A steel-spring-floating slab track and ordinary monolithic track tunnel sites with similar line conditions on straight and curved segments were selected. The vibration signals of rail, track bed, and tunnel walls were collected and the analysis results of vibration damping and vibration transmission between the steel-spring-floating slab track and the ordinary monolithic track were compared. Results: The dynamic responses of the rail in the four working conditions are relatively close, and the acceleration of the steel-spring-floating slab track bed is significantly larger than that of the ordinary monolithic track. The vibration response generated in the curved segment is significantly greater, and each frequency band will generate more peak points, and the high-frequency vibration will be more severe. Conclusions: The steel-spring-floating slab track can significantly reduce the acceleration response of the tunnel wall; the bottom constraint of the steel-spring-floating slab track is less, and the vibration response of the track bed is more severe.