Jujhar Singh

Dr. Jujhar Singh


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SSSHUBHAM SHARMA
SHUBHAM SHARMA
PSPosa Sudhakara
Posa Sudhakara
AOAbdoulhdi A. Borhana Omran
Abdoulhdi A. Borhana Omran
JSJujhar Singh
Jujhar Singh
Ahmad Ilyas RushdanAhmad Ilyas Rushdan
Ahmad Ilyas Rushdan
Electrically-conducting polymers (CPs) were first developed as a revolutionary class of organic compounds that possess optical and electrical properties comparable to that of metals as well as inorganic semiconductors and display the commendable properties correlated with traditional polymers, like the ease of manufacture along with resilience in processing. Polymer nanocomposites are designed and manufactured to ensure excellent promising properties for anti-static (electrically conducting), anti-corrosion, actuators, sensors, shape memory alloys, biomedical, flexible electronics, solar cells, fuel cells, supercapacitors, LEDs, and adhesive applications with desired-appealing and cost-effective, functional surface coatings. The distinctive properties of nanocomposite materials involve significantly improved mechanical characteristics, barrier-properties, weight-reduction, and increased, long-lasting performance in terms of heat, wear, and scratch-resistant. Constraint in availability of power due to continuous depletion in the reservoirs of fossil fuels has affected the performance and functioning of electronic and energy storage appliances. For such reasons, efforts to modify the performance of such appliances are under way through blending design engineering with organic electronics. Unlike conventional inorganic semiconductors, organic electronic materials are developed from conducting polymers (CPs), dyes and charge transfer complexes. However, the conductive polymers are perhaps more bio-compatible rather than conventional metals or semi-conductive materials. Such characteristics make it more fascinating for bio-engineering investigators to conduct research on polymers possessing antistatic properties for various applications. An extensive overview of different techniques of synthesis and the applications of polymer bio-nanocomposites in various fields of sensors, actuators, shape memory polymers, flexible electronics, optical limiting, electrical properties (batteries, solar cells, fuel cells, supercapacitors, LEDs), corrosion-protection and biomedical application are well-summarized from the findings all across the world in more than 150 references, exclusively from the past four years. This paper also presents recent advancements in composites of rare-earth oxides based on conducting polymer composites. Across a variety of biological and medical applications, the fact that numerous tissues were receptive to electric fields and stimuli made CPs more enticing.

6 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
SSSHUBHAM SHARMA
SHUBHAM SHARMA
SSSHUBHAM SHARMA
SHUBHAM SHARMA
JSJujhar Singh
Jujhar Singh
Ahmad Ilyas RushdanAhmad Ilyas Rushdan
Ahmad Ilyas Rushdan
PRProf. Dr. Muhammad Rizal Razman
Prof. Dr. Muhammad Rizal Razman
PRProf. Dr. Muhammad Rizal Razman
Prof. Dr. Muhammad Rizal Razman
In the determination of the bioavailability of drugs administered orally, the drugs’ solubility and permeability play a crucial role. For absorption of drug molecules and production of a pharmacological response, solubility is an important parameter that defines the concentration of the drug in systemic circulation. It is a challenging task to improve the oral bioavailability of drugs that have poor water solubility. Most drug molecules are either poorly soluble or insoluble in aqueous environments. Polymer nanocomposites are combinations of two or more different materials that possess unique characteristics and are fused together with sufficient energy in such a manner that the resultant material will have the best properties of both materials. These polymeric materials (biodegradable and other naturally bioactive polymers) are comprised of nanosized particles in a composition of other materials. A systematic search was carried out on Web of Science and SCOPUS using different keywords, and 485 records were found. After the screening and eligibility process, 88 journal articles were found to be eligible, and hence selected to be reviewed and analyzed. Biocompatible and biodegradable materials have emerged in the manufacture of therapeutic and pharmacologic devices, such as impermanent implantation and 3D scaffolds for tissue regeneration and biomedical applications. Substantial effort has been made in the usage of bio-based polymers for potential pharmacologic and biomedical purposes, including targeted deliveries and drug carriers for regulated drug release. These implementations necessitate unique physicochemical and pharmacokinetic, microbiological, metabolic, and degradation characteristics of the materials in order to provide prolific therapeutic treatments. As a result, a broadly diverse spectrum of natural or artificially synthesized polymers capable of enzymatic hydrolysis, hydrolyzing, or enzyme decomposition are being explored for biomedical purposes. This summary examines the contemporary status of biodegradable naturally and synthetically derived polymers for biomedical fields, such as tissue engineering, regenerative medicine, bioengineering, targeted drug discovery and delivery, implantation, and wound repair and healing. This review presents an insight into a number of the commonly used tissue engineering applications, including drug delivery carrier systems, demonstrated in the recent findings. Due to the inherent remarkable properties of biodegradable and bioactive polymers, such as their antimicrobial, antitumor, anti-inflammatory, and anticancer activities, certain materials have gained significant interest in recent years. These systems are also actively being researched to improve therapeutic activity and mitigate adverse consequences. In this article, we also present the main drug delivery systems reported in the literature and the main methods available to impregnate the polymeric scaffolds with drugs, their properties, and their respective benefits for tissue engineering.

4 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
LRLalit ranakoti
Lalit ranakoti
BGBrijesh Gangil
Brijesh Gangil
Prabhakar BhandariPrabhakar Bhandari
Prabhakar Bhandari
Tej SinghTej Singh
Tej Singh
SSSHUBHAM SHARMA
SHUBHAM SHARMA
Sunpreet SinghSunpreet Singh
Sunpreet Singh
In the present scenario, the research is now being focused on the naturally occurring polymers that can gradually replace the existing synthetic polymers for the development of bio composites having applications in medical surgeries and human implants. With promising mechanical properties and bio compatibility with human tissues, poly lactic acid (PLA) is now being viewed as a future bio material. In order to examine the applicability of PLA in human implants, the current article sheds light on the synthesis of PLA and its various copolymers used to alter its physical and mechanical properties. In the latter half, various processes used for the fabrication of biomaterials are discussed in detail. Finally, biomaterials that are currently in use in the field of biomedical (Scaffolding, drug delivery, tissue engineering, medical implants, derma, cosmetics, medical surgeries, and human implants) are represented with respective advantages in the sphere of biomaterials.

6 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
Vivek AggarwalVivek Aggarwal
Vivek Aggarwal
Catalin PruncuCatalin Pruncu
Catalin Pruncu
JSJujhar Singh
Jujhar Singh
SSSHUBHAM SHARMA
SHUBHAM SHARMA
Danil PimenovDanil Pimenov
Danil Pimenov
Monel K-500, a nickel–copper based alloy, is a very hard and tough material. Machining of such hard and tough materials always becomes a challenge for industry and this has been resolved by wire electric discharge machining (WEDM), a popular non-conventional machining method used for machining tough and hard materials having complex shapes. For the first time reported in this present research work is an experimental investigation executed on Ni-27Cu-3.15Al-2Fe-1.5Mn based superalloy using WEDM to model cutting rate (CR) and surface roughness (SR) using response surface methodology (RSM). The process parameters have been selected as pulse-on time, pulse-off time, spark-gap voltage and wire-feed rate. Experiments have been planned according to the central composite design (CCD). The results show that pulse-on time has a direct effect on CR while the pulse-off time has a reverse effect. The CR increases as pulse-on time increases, and decreases as pulse-off time increases. SR increases as pulse-on time increases, and decreases as pulse-off time increases. Furthermore, increase in spark-gap voltage decreases CR and SR both. The wire feed-rate has a negligible effect for both the response parameters. The optimized values of CR and SR achieved through multi-response optimization are 2.48 mm/min and 2.12 µm, respectively.

24 May 2021 in Lasers in Manufacturing and Materials Processing
Verified
Journal Article
Open access
PDF file
YSYadvinder Singh
Yadvinder Singh
JSJujhar Singh
Jujhar Singh
SSSHUBHAM SHARMA
SHUBHAM SHARMA
Vivek AggarwalVivek Aggarwal
Vivek Aggarwal
Catalin PruncuCatalin Pruncu
Catalin Pruncu
Current research focuses on optimizing various quality characteristics for kerf geometry generated through laser cutting of Coir fibre/carbon fibre/epoxy resin hybrid composite adjacent to straight cut profile employing pulsed CO2 laser system. The Kerf taper (KT) and the Surface roughness (SR) are the main quality parameters discussed. Dependent on significant process parameters, namely gas pressure, cutting speed, pulse frequency and pulse width predictive models were developed. In accordance with Taguchi's L9 orthogonal array (OA), the cutting trials are designed. Process-parametric optimization was performed using Response Surface Methodology (RSM). Furthermore, experiments were performed to obtain experimental data for the analysis of cut quality features. The impact of the input variables on the response characteristics is also explored. The morphological characterizations have been performed to analysis the effect of machining-variables and cut-quality for the top and bottom kerf widths with various laser cutting variables in the pulse laser-cutting of Coir-fibre/carbon-fibre/epoxy-resin hybrid composite. For SR and KT, the developed second order surface response model was found very successful. The optimal levels of cutting variables for KT are established at Gas pressure-6 N/mm2, pulse width-2.04 ms, cutting speed-8.01 mm/s, pulse frequency-15 Hz, for sample A1, Gas pressure-5.47 N/mm2, pulse width-2.5 ms, cutting speed-8.81 mm/s, pulse frequency-8.43 Hz, for sample A2, Gas pressure-3.85 N/mm2, pulse width-1.5 ms, cutting speed-9.06 mm/s, pulse frequency-5 Hz, for sample A3 additionally for SR Gas pressure-2 N/mm2, pulse width-1.5 ms, cutting speed-7 mm/s, pulse frequency-5 Hz, for sample A1, Gaspressure-2.36 N/mm2, pulse width-1.5 ms, cutting speed-7 mm/s, pulse frequency-15 Hz, for sample A2, Gaspressure-6 N/mm2, pulse width-1.5 ms, cutting speed-11 mm/s, pulse frequency-8.73 Hz, for sample A3. Regression results and linear and square impact of laser cutting variables have been revealed to be important to validate the model.

19 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
ATAditya Kumar Tiwary
Aditya Kumar Tiwary
Sandeep SinghSandeep Singh
Sandeep Singh
Raman KumarRaman Kumar
Raman Kumar
JCJasgurpreet Singh Chohan
Jasgurpreet Singh Chohan
SSSHUBHAM SHARMA
SHUBHAM SHARMA
SSSHUBHAM SHARMA
SHUBHAM SHARMA
Concrete is a composite material that is commonly used in the construction industry. It will certainly be exposed to fires of varying intensities when used in buildings and industries. The major goal of this article was to look into the influence of mineral additions such as foundry sand and marble dust on the residual characteristics of concrete. To examine the behavior of residual characteristics of concrete after fire exposure, marble dust was substituted for cement and fine sand was substituted for foundry sand in varying amounts ranging from 0% to 20%. It aided in the better disposal of waste material so that it might be used as an addition. The purpose of the experiment was to see how increased temperatures affected residual properties of concrete, including flexural strength, compressive strength, tensile strength, static as well as dynamic elastic modulus, water absorption, mass loss, and ultrasonic pulse velocity. At temperatures of 200 °C, 400 °C, 600 °C, 800 °C, and 1000 °C, the typical fire exposure behavior of concrete was investigated. The effects of two cooling techniques, annealing and quenching, on the residual properties of concrete after exposure to high temperatures were investigated in this study. Replacement of up to 10% of the cement with marble dust and fine sand with foundry sand when concrete is exposed to temperatures up to 400 °C does not influence the behavior of concrete. At temperatures above 400 °C, however, the breakdown of concrete, which includes marble dust and foundry sand, causes a rapid deterioration in the residual properties of concrete, primarily for replacement of more than 10%.