This article presents an automatic parameter identification method based on ordinary least square (OLS) algorithm for deadbeat predictive current control (DPCC) to fulfill the purpose of high steady and dynamic performance in permanent magnet synchronous motor (PMSM) drives. Different from the conventional model, a novel model based on the polynomial estimation of flux linkage is constructed which takes the cross-saturation effects into account. First, the conventional mathematical model of PMSM and the proposed model are presented, respectively, and the inverter considering nonideal factors is also analyzed. Then the parameter identification method is investigated, in which the measurement procedure is delimited in advance and the automatic identification method is developed. Furthermore, a voltage reconstruction algorithm is applied to solve the inverter nonlinearities and the digital time-delay effect, so as to improve the accuracy of the identified parameters. Accordingly, a novel DPCC algorithm is presented based on the proposed model to achieve better performance. Finally, based on the concept and principles mentioned before, a detailed comparison of the DPCC based on the classical model considering the parameters’ variation and the modified model of the proposed method is carried out on a laboratory prototype.
An asymmetric, cross-coupling effect, as well as digital control delays, in a permanent-magnet synchronous motor (PMSM) will deteriorate its current-control performance in the high-speed range, especially for electric motors used in electric vehicles (EVs) with features such as high-power density and a low carrier/modulation frequency ratio. In this paper, an angle-compensating, complex-coefficient, proportional-integrator (ACCC-PI) controller is proposed, which aims to provide an excellent decoupling performance even with considerable digital control delay. Firstly, the current open and closed loop complex-coefficient transfer functions were established in the synchronous rotation coordinate system. The proposed method, along with existing ones, were then evaluated and theoretically compared. On this basis, the parameter-tuning method of the ACCC-PI controller was presented. Finally, simulation and experimental results proved the correctness of the theoretical analysis and the proposed method.
Currently, the planning of electric vehicle(EV) charging piles usually adopts the analogy methods, which would bring great deviations due to the lack of considering the influence of regional driving characteristics and the scale of electric vehicles. In this paper, a three-state probability model with four parameters was proposed. The number of fast charging piles was calculated based on various regional driving characteristics. Calculation results of the fast charging pile in typical areas are also calculated which can provide reference for the planning department.
Discrete Silicon Carbide Metal-Oxide-Semiconductor Field-Effect Transistors (SiC MOSFETs) are characterized by their lower parasitic parameters and single-chip design, enabling them to achieve even faster switching speeds. However, the rapid rate of change in voltage (dv/dt) and current (di/dt) can lead to overshoot and oscillation in both voltage and current, ultimately limiting the performance of high-frequency operations. To address this issue, this paper presents a high-switching-frequency motor controller that utilizes discrete SiC MOSFETs. To achieve a high switching frequency for the controller while minimizing current oscillation and voltage overshoot, a novel electronic system architecture is proposed. Additionally, a passive driving circuit is designed to suppress gate oscillation without the need for additional control circuits. A new printed circuit board (PCB) laminate stack featuring low parasitic inductance, high current conduction capacity, and efficient heat dissipation is also developed using advanced wiring technology and a specialized heat dissipation structure. Compared to traditional methods, the proposed circuit and bus design features a simpler structure, a higher power density, and achieves a 13% reduction in current overshoot, along with a 15.7% decrease in switching loss. The silicon carbide (SiC) controller developed from this research has successfully undergone double-pulse and power testing. The results indicate that the designed controller can operate reliably over extended periods at a switching frequency of 50 kHz, achieving a maximum efficiency of 98.2% and a power density of 9 kW/kg (10 kW/L). The switching frequency and quality density achieved by the controller have not been observed in previous studies. This controller is suitable for use in the development of new energy electrical systems.
12 April 2026 in Case Studies in Thermal Engineering