In this article we report a new, simple, and reliable optical read-out detection method able to assess Rotavirus present in human sera as well as in the viral pollution sources. It is based on the interference of two interferometers used as biophotonic transducers. The method significantly improves the optical label-free biosensing response measuring both, the concentration of the AgR and its corresponding size. Two different immunoassays were carried out: Bovine Serum Albumin (BSA), and the recognition by its antibody (anti-BSA); and Rotavirus (AgR) and the recognition by its antibody (anti-AgR). In the cases studied, and using as model interferometer a simple Fabry-Perot transducer, we demonstrate a biosensing enhancement of two orders of magnitude in the Limit of Detection (LoD). In fact, this read-out optical method may have significant implications to enhance other optical label-free photonic transducers reported in the scientific literature.
Despite the remarkable development related to Point-of-Care devices based on optical technology, their difficulties when used outside of research laboratories are notable. In this sense, it would be interesting to ask ourselves what the degree of transferability of the research work to the market is, for example, by analysing the relation between the scientific work developed and the registered one, through patent. In this work, we provide an overview of the state-of-the-art in the sector of optical Point-of-Care devices, not only in the research area but also regarding their transfer to market. To this end, we explored a methodology for searching articles and patents to obtain an indicator that relates to both. This figure of merit to estimate this transfer is based on classifying the relevant research articles in the area and the patents that have been generated from these ones. To delimit the scope of this study, we researched the results of a large enough number of publications in the period from 2015 to 2020, by using keywords “biosensor”, “optic”, and “device” to obtain the most representative articles from Web of Science and Scopus. Then, we classified them according to a particular classification of the optical PoC devices. Once we had this sampling frame, we defined a patent search strategy to cross-link the article with a registered patent (by surfing Google Patents) and classified them accordingly to the categories described. Finally, we proposed a relative figure called Index of Technology Transference (IoTT), which estimates to what extent our findings in science materialized in published articles are protected by patent.
9 January 2020 in Measurement Science and Technology
This work describes a procedure to obtain the limit of detection (LoD) of a biosensor device from a set of measurements that we call immunoassays, which consists of testing the device’s response to different concentrations of the molecule, which has to be detected throughout its working range. The procedure, based on the recommendations of international organizations, provides general expressions to estimate the uncertainty throughout its working range and the LoD. In the metrological model, the contributions to the uncertainty, due to the determination of the parameters of the calibration curve, the resolution, the lack of repeatability and others are taken into account. The model is applied to experimental data from the calibration of a biosensor. Using iterative weighted least squares techniques, a general logistic function (6-parameters) has been fitted and used as a calibration curve. The example studied shows that the lack of repeatability is not always the most important contribution to the LoD. The final expression of the LoD is equivalent to that of the expanded uncertainty (for a coverage probability of 99.9%) assigned to the concentration when . This result permits seeing the LoD as the smallest concentration measured with the device, whereby uncertainty interval does not include negative values.
A novel compact optical biochip based on a thin layer-sensing surface of nitrocellulose is used for in-situ label-free detection of metalloproteinase (MMP9) related to dry eye disease. In this article, a new integrated chip with different interferometric transducers layout with an optimal sensing surface is reported for the first time. We demonstrate that specific antibodies can be immobilized onto these transducers with a very low volume of sample and with good orientation. Many sensing transducers constitute the presented biochip in order to yield statistical data and stability in the acquired measurements. As a result, we report the recognition curve for pure recombinant MMP9, tests of model tears with MMP9, and real tear performance from patients, with a promising limit of detection.
The specificity and affinity of antibody-antigen interactions is a fundamental way to achieve reliable biosensing responses. Different proteins involved with dry eye dysfunction: ANXA1, ANXA11, CST4, PRDX5, PLAA and S100A6; were validated as biomarkers. In this work several antibodies were tested for ANXA1, ANXA11 and PRDX5 to select the best candidates for each biomarker. The results were obtained by using Biophotonic Sensing Cells (BICELLs) as an efficient methodology for label-free biosensing and compared with the Enzyme-Linked Immuno Sorbent Assay (ELISA) technique.
In this scientific work, we demonstrate, for the first time, a new biosensing system and procedure to measure specifically the total Tau (T-Tau) protein in serum, one of the most relevant biomarkers of Alzheimer’s disease (AD). AD is a progressive brain disorder that produces neuronal and cognitive dysfunction and affects a high percentage of people worldwide. For this reason, diagnosing AD at the earliest possible stage involves improving diagnostic systems. We report on the use of interferometric bio-transducers integrated with 65 microwells forming diagnostic KITs read-out by using the Interferometric Optical Detection Method (IODM). Moreover, biofunctionalized silicon dioxide (SiO2) nanoparticles (NPs) acting as interferometric enhancers of the bio-transducers signal allow for the improvement of both the optical read-out signal and its ability to work with less-invasive biological samples such as serum instead of cerebrospinal fluid (CSF). As a result, in this paper, we describe for the first time a relevant diagnostic alternative to detect Tau protein at demanding concentrations of 10 pg/mL or even better, opening the opportunity to be used for detecting other relevant AD-related biomarkers in serum, such as β-amyloid and phosphorylated Tau (P-Tau), neurofilaments, among others that can be considered relevant for AD.