Yolanda Ramirez

Mrs. Yolanda Ramirez

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ÁLÁlvaro Lavín
Álvaro Lavín
Jesus De Vicente y OlivaJesus De Vicente y Oliva
Jesus De Vicente y Oliva
Miguel HolgadoMiguel Holgado
Miguel Holgado
Mariafe LagunaMariafe Laguna
Mariafe Laguna
RCRafael Casquel
Rafael Casquel
YRYolanda Ramirez
Yolanda Ramirez
A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.

5 July 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AMAna María M. Murillo
Ana María M. Murillo
Mariafe LagunaMariafe Laguna
Mariafe Laguna
LVLuis Gonzalez Valle
Luis Gonzalez Valle
LTLuca Tramarin
Luca Tramarin
YRYolanda Ramirez
Yolanda Ramirez
Miguel HolgadoMiguel Holgado
Miguel Holgado
In this scientific work, we demonstrate, for the first time, a new biosensing system and procedure to measure specifically the total Tau (T-Tau) protein in serum, one of the most relevant biomarkers of Alzheimer’s disease (AD). AD is a progressive brain disorder that produces neuronal and cognitive dysfunction and affects a high percentage of people worldwide. For this reason, diagnosing AD at the earliest possible stage involves improving diagnostic systems. We report on the use of interferometric bio-transducers integrated with 65 microwells forming diagnostic KITs read-out by using the Interferometric Optical Detection Method (IODM). Moreover, biofunctionalized silicon dioxide (SiO2) nanoparticles (NPs) acting as interferometric enhancers of the bio-transducers signal allow for the improvement of both the optical read-out signal and its ability to work with less-invasive biological samples such as serum instead of cerebrospinal fluid (CSF). As a result, in this paper, we describe for the first time a relevant diagnostic alternative to detect Tau protein at demanding concentrations of 10 pg/mL or even better, opening the opportunity to be used for detecting other relevant AD-related biomarkers in serum, such as β-amyloid and phosphorylated Tau (P-Tau), neurofilaments, among others that can be considered relevant for AD.

24 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Mariafe LagunaMariafe Laguna
Mariafe Laguna
YRYolanda Ramirez
Yolanda Ramirez
CMCelia Fernández Martín
Celia Fernández Martín
REROCIO L. ESPINOSA
ROCIO L. ESPINOSA
ALAlvaro Lavín
Alvaro Lavín
Miguel HolgadoMiguel Holgado
Miguel Holgado
Interferon-gamma (IFN-γ) is a cytokine associated with inflammatory diseases, virus, infection, etc. The quantification of interferon-gamma concentration levels is studied to relate the immune system response to the progression of disease. In this work, we used a label-free point-of-care device based on the increase relative optical power (IROP) and a biosensor based on photonic transducers called BICELLs (Biophotonic Sensing Cells) to evaluate interferon-gamma concentrations. The BICELLs’ sensing surface size used is 100 μm in diameter. The bioreceptor is attached to the surface by streptavidin-biotin affinity. This label-free IROP-based device can work with a low concentration of reagents and a low sample volume for measurements. Furthermore, this new device was compared with an ELISA technique in the same conditions. A good correlation was achieved between both techniques. This device is easy to use, and it is a cost-effective tool for monitoring an analyte in a disease.

5 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YRYolanda Ramirez
Yolanda Ramirez
Mariafe LagunaMariafe Laguna
Mariafe Laguna
Miguel HolgadoMiguel Holgado
Miguel Holgado
We developed a new label-free assay to evaluate the inhibition capacity of AX-024 by means of a new Point-of-Care (PoC) device for application in the development of new drugs in autoimmune diseases. The technology of PoC is based on interferometric optical detection method (IODM). For this purpose, we have optimized and developed an assay protocol whereby a Glutathione S-Transferase modified protein (GST-SH3.1), which contains a functional domain of a protein involved in T-cell activation, together with the AX-024 inhibitor has been studied. The chips used are a sensing surface based on nitrocellulose. We used streptavidin and a biotinylated peptide as links for the immobilization process on the sensing surface. The biotinylated peptide and AX-024 inhibitor compete for the same functional group of the GST-SH3.1 modified protein. When the inhibitor binds its binding site on GST-SH3.1, the biotinylated peptide cannot bind to its pocket on the protein. This competition reduces the total molecular mass of protein fixed onto the biosensor. In order to quantify the inhibition capacity of AX-024, several Ax-024:GST-SH3.1 ratios have been studied. We have compared the read-out signal for GST-SH3.1 protein not interfered by the drug, which served as a positive blank, and the response of the GST-SH3.1 modified protein blocked by the inhibitor. The technology has been correlated with confocal fluorescence microscopy.