Rafael Casquel

Dr. Rafael Casquel

1) Applied Physics and Materials Engineering, ETSI Industriales, Universidad Politécnica de Madrid., Universidad Politécnica de Madrid. José Gutiérrez Abascal 2, 28006 Madrid, Spain
+1

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ÁLÁlvaro Lavín
Álvaro Lavín
Jesus De Vicente y OlivaJesus De Vicente y Oliva
Jesus De Vicente y Oliva
Miguel HolgadoMiguel Holgado
Miguel Holgado
Mariafe LagunaMariafe Laguna
Mariafe Laguna
RCRafael Casquel
Rafael Casquel
YRYolanda Ramirez
Yolanda Ramirez
A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.

21 February 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Miguel HolgadoMiguel Holgado
Miguel Holgado
FSFrancisco J. Sanza
Francisco J. Sanza
AHAna L Hernandez
Ana L Hernandez
ALAlvaro Lavín
Alvaro Lavín
RCRafael Casquel
Rafael Casquel
Mariafe LagunaMariafe Laguna
Mariafe Laguna
In this article we report a new, simple, and reliable optical read-out detection method able to assess Rotavirus present in human sera as well as in the viral pollution sources. It is based on the interference of two interferometers used as biophotonic transducers. The method significantly improves the optical label-free biosensing response measuring both, the concentration of the AgR and its corresponding size. Two different immunoassays were carried out: Bovine Serum Albumin (BSA), and the recognition by its antibody (anti-BSA); and Rotavirus (AgR) and the recognition by its antibody (anti-AgR). In the cases studied, and using as model interferometer a simple Fabry-Perot transducer, we demonstrate a biosensing enhancement of two orders of magnitude in the Limit of Detection (LoD). In fact, this read-out optical method may have significant implications to enhance other optical label-free photonic transducers reported in the scientific literature.

29 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
MPMaría Jesús Pioz
María Jesús Pioz
REROCIO L. ESPINOSA
ROCIO L. ESPINOSA
Mariafe LagunaMariafe Laguna
Mariafe Laguna
Beatriz SantamaríaBeatriz Santamaría
Beatriz Santamaría
AMAna María M. Murillo
Ana María M. Murillo
Miguel HolgadoMiguel Holgado
Miguel Holgado
Despite the remarkable development related to Point-of-Care devices based on optical technology, their difficulties when used outside of research laboratories are notable. In this sense, it would be interesting to ask ourselves what the degree of transferability of the research work to the market is, for example, by analysing the relation between the scientific work developed and the registered one, through patent. In this work, we provide an overview of the state-of-the-art in the sector of optical Point-of-Care devices, not only in the research area but also regarding their transfer to market. To this end, we explored a methodology for searching articles and patents to obtain an indicator that relates to both. This figure of merit to estimate this transfer is based on classifying the relevant research articles in the area and the patents that have been generated from these ones. To delimit the scope of this study, we researched the results of a large enough number of publications in the period from 2015 to 2020, by using keywords “biosensor”, “optic”, and “device” to obtain the most representative articles from Web of Science and Scopus. Then, we classified them according to a particular classification of the optical PoC devices. Once we had this sampling frame, we defined a patent search strategy to cross-link the article with a registered patent (by surfing Google Patents) and classified them accordingly to the categories described. Finally, we proposed a relative figure called Index of Technology Transference (IoTT), which estimates to what extent our findings in science materialized in published articles are protected by patent.

14 February 2020 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
RCRafael Casquel
Rafael Casquel
Miguel HolgadoMiguel Holgado
Miguel Holgado
Mariafe LagunaMariafe Laguna
Mariafe Laguna
AHAna L. Hernández
Ana L. Hernández
Beatriz SantamaríaBeatriz Santamaría
Beatriz Santamaría
PHPedro Herreros
Pedro Herreros
In this work, we review the technology of vertically interrogated optical biosensors from the point of view of engineering. Vertical sensors present several advantages in the fabrication processes and in the light coupling systems, compared with other interferometric sensors. Four different interrelated aspects of the design are identified and described: sensing cell design, optical techniques used in the interrogation, fabrication processes, fluidics, and biofunctionalization of the sensing surface. The designer of a vertical sensor should decide carefully which solution to adopt on each aspect prior to finally integrating all the components in a single platform. Complexity, cost, and reliability of this platform will be determined by the decisions taken on each of the design process. We focus on the research and experience acquired by our group during last years in the field of optical biosensors.

13 August 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Mariafe LagunaMariafe Laguna
Mariafe Laguna
Miguel HolgadoMiguel Holgado
Miguel Holgado
Ana HernándezAna Hernández
Ana Hernández
Beatriz SantamaríaBeatriz Santamaría
Beatriz Santamaría
ALAlvaro Lavín
Alvaro Lavín
RCRafael Casquel
Rafael Casquel
The specificity and affinity of antibody-antigen interactions is a fundamental way to achieve reliable biosensing responses. Different proteins involved with dry eye dysfunction: ANXA1, ANXA11, CST4, PRDX5, PLAA and S100A6; were validated as biomarkers. In this work several antibodies were tested for ANXA1, ANXA11 and PRDX5 to select the best candidates for each biomarker. The results were obtained by using Biophotonic Sensing Cells (BICELLs) as an efficient methodology for label-free biosensing and compared with the Enzyme-Linked Immuno Sorbent Assay (ELISA) technique.

14 August 2012 in Biosensors
Verified
Journal Article
Open access
PDF file
FOFrancisco J. Ortega
Francisco J. Ortega
MBMaria-Jose Bañuls
Maria-Jose Bañuls
FSFrancisco J. Sanza
Francisco J. Sanza
RCRafael Casquel
Rafael Casquel
Mariafe LagunaMariafe Laguna
Mariafe Laguna
RPRosa Puchades
Rosa Puchades
In this paper, label-free biosensing for antibody screening by periodic lattices of high-aspect ratio SU-8 nano-pillars (BICELLs) is presented. As a demonstration, the determination of anti-gestrinone antibodies from whole rabbit serum is carried out, and for the first time, the dissociation constant (KD = 6 nM) of antigen-antibody recognition process is calculated using this sensing system. After gestrinone antigen immobilization on the BICELLs, the immunorecognition was performed. The cells were interrogated vertically by using micron spot size Fourier transform visible and IR spectrometry (FT-VIS-IR), and the dip wavenumber shift was monitored. The biosensing assay exhibited good reproducibility and sensitivity (LOD = 0.75 ng/mL).