Miguel Holgado

Prof. Miguel Holgado

Universidad Politécnica de Madrid, Madrid, Spain
+3
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2007 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Carlos  BarriosCarlos Barrios
Carlos Barrios
KGKristinn Gylfason
Kristinn Gylfason
BSBenito Sánchez
Benito Sánchez
AGAmadeu Griol
Amadeu Griol
HSH. Sohlström
H. Sohlström
RCR. Casquel
R. Casquel
We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguide microring resonator. The microresonator is fabricated on a Si3N4–SiO2 platform and operates at a wavelength of 1.3 μm. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n=1.33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2×10−4 RIU.

1 March 1997 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
RMRaul Mayoral
Raul Mayoral
JRJoaquin Requena
Joaquin Requena
JMJosé S. Moya
José S. Moya
CLCefe López
Cefe López
ACAdelaida Cintas
Adelaida Cintas
ÁBÁlvaro Blanco
Álvaro Blanco

3 June 1999 in Langmuir
Verified
Journal Article
Closed access
Miguel HolgadoMiguel Holgado
Miguel Holgado
FGF. García-Santamaría
F. García-Santamaría
ABA. Blanco
A. Blanco
MIM. Ibisate
M. Ibisate
ACA. Cintas
A. Cintas
CLCefe López
Cefe López

28 March 2008 in Optics Letters
Verified
Journal Article
Open access
PDF file
Carlos  BarriosCarlos Barrios
Carlos Barrios
MBMaria-Jose Bañuls
Maria-Jose Bañuls
VGVictoria González-Pedro
Victoria González-Pedro
KGKristinn Gylfason
Kristinn Gylfason
BSBenito Sánchez
Benito Sánchez
RCR. Casquel
R. Casquel
We demonstrate label-free molecule detection by using an integrated biosensor based on a Si3N4∕SiO2 slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2nm∕(ng∕mm2) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16pg∕mm2 for anti-BSA and BSA, respectively, limited by wavelength resolution.

15 May 1999 in Physical Review B
Verified
Journal Article
Closed access
PDF file
Francisco J MeseguerFrancisco J Meseguer
Francisco J Meseguer
Miguel HolgadoMiguel Holgado
Miguel Holgado
DCD. Caballero
D. Caballero
NBN. Benaches
N. Benaches
Jose Sanchez-DehesaJose Sanchez-Dehesa
Jose Sanchez-Dehesa
JLJ. Llinares
J. Llinares
In this paper, we report experiments on the scattering of surface-elastic waves by a periodic array of cylindrical holes. The experiments were performed in a marble quarry by drilling cylindrical holes in two different configurations: honeycomb and triangular lattices. The attenuation spectra of the surface waves show the existence of absolute band gaps for elastic waves in these semi-infinite two-dimensional crystals. Results are compared with theoretical calculations based on a scalar-wave approach. The scaling property of the underlying theory has led us to explore the possible application of the results obtained to the attenuation of surface waves in seismic movements.

26 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ÁLÁlvaro Lavín
Álvaro Lavín
Jesus De Vicente y OlivaJesus De Vicente y Oliva
Jesus De Vicente y Oliva
Miguel HolgadoMiguel Holgado
Miguel Holgado
Mariafe LagunaMariafe Laguna
Mariafe Laguna
RCRafael Casquel
Rafael Casquel
YRYolanda Ramirez
Yolanda Ramirez
A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.